Michael R. Stinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael R. Stinson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Gilles A. Daigle
Natl. Res. Council of Canada, Ottawa, ON K1A 0R6 Canada
15 shared publicationsDavid I. Havelock
Inst. for Microstructural Sciences, Natl. Res. Council, Ottawa, ON K1A 0R6, Canada)
3 shared publicationsJohn F. Quaroni
National Research Council Institute for Microstructural Sciences Ottawa, Ontario K1A 0R6, Canada
2 shared publicationsBradford N. Gover
Inst. for Res. in Construction, Natl. Res. Council of Canada, Ottawa, ON K1A 0R6 Canada
1 shared publicationG. A. Daigle
National Research Council Institute for Microstructural Sciences Ottawa, Ontario K1A 0R6, Canada
1 shared publication- Wenhao Zhu
Institute for Microstructural Sciences, National Research Council, Ottawa, Ontario, Canada
1 shared publication
Latest Publications
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2544
Speech intelligibility improvement in rooms using microphone arrays.
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2544
Speech intelligibility improvement in rooms using microphone arrays.
- 1 June 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 121 (6) , 3689-3702
Transverse pressure distributions in a simple model ear canal occluded by a hearing aid test fixture
The sound field in a model ear canal with a hearing aid test fixture has been investigated experimentally and theoretically. Large transverse variations of sound pressure level, as much as 20dB at 8kHz, were found across the inner face of the hearing aid. Variations are greatest near the outlet port of the receiver and the vent port. Deeper into the canal, the transverse variations are less significant and, at depths greater than 4mm, only a longitudinal variation remains. The model canal was cylindrical, 7.5mm diameter, and terminated with a Zwislocki coupler to represent absorption by the human middle ear. The outer end of the canal was driven by the receiver in the hearing aid test fixture, with the acoustic output entering the canal through a 1mm port. The hearing aid was provided with a 20-mm-long vent, either 1 or 2mm in diameter. The sound field inside the canal was measured using a specially designed 0.2-mm-diam probe microphone [Daigle and Stinson, J. Acoust. Soc. Am. 116, 2618 (2004)]. In parallel, calculations of the interior sound field were performed using a boundary element technique and found to agree well with measurements.
- 1 June 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 121 (6) , 3689-3702
Transverse pressure distributions in a simple model ear canal occluded by a hearing aid test fixture
The sound field in a model ear canal with a hearing aid test fixture has been investigated experimentally and theoretically. Large transverse variations of sound pressure level, as much as 20dB at 8kHz, were found across the inner face of the hearing aid. Variations are greatest near the outlet port of the receiver and the vent port. Deeper into the canal, the transverse variations are less significant and, at depths greater than 4mm, only a longitudinal variation remains. The model canal was cylindrical, 7.5mm diameter, and terminated with a Zwislocki coupler to represent absorption by the human middle ear. The outer end of the canal was driven by the receiver in the hearing aid test fixture, with the acoustic output entering the canal through a 1mm port. The hearing aid was provided with a 20-mm-long vent, either 1 or 2mm in diameter. The sound field inside the canal was measured using a specially designed 0.2-mm-diam probe microphone [Daigle and Stinson, J. Acoust. Soc. Am. 116, 2618 (2004)]. In parallel, calculations of the interior sound field were performed using a boundary element technique and found to agree well with measurements.
- 1 May 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 121 (5_Suppleme) , 3066
Over 75 years of acoustics at the National Research Council of Canada
- 1 May 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 121 (5_Suppleme) , 3066
Over 75 years of acoustics at the National Research Council of Canada
- 1 July 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (1) , 186-191
Design and performance of a microprobe attachment for a 12-in. microphone
Peer reviewed: NoNRC publication: Ye
- 1 July 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (1) , 186-191
Design and performance of a microprobe attachment for a 12-in. microphone
Peer reviewed: NoNRC publication: Ye
- 1 October 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 118 (4) , 2405-2411
Comparison of an analytic horn equation approach and a boundary element method for the calculation of sound fields in the human ear canal
The sound field inside a model human ear canal has been computed, to show both longitudinal variations along the canal length and transverse variations through cross-sectional slices. Two methods of computation were used. A modified horn equation approach parametrizes the sound field with a single coordinate, the position along a curved center axis—this approach can accommodate the curvature and varying cross-sectional area of the ear canal but cannot compute transverse variations of the sound field. A boundary element method (BEM) was also implemented to compute the full three-dimensional sound field. Over 2000 triangular mesh elements were used to represent the ear canal geometry. For a plane piston source at the entrance plane, the pressure along the curved center axis predicted by the two methods is in good agreement, for frequencies up to , for four different ear canals. The BEM approach, though, reveals spatial variations of sound pressure within each canal cross section. These variations are small below , but increase with frequency, reaching at and at . For source configurations that are more realistic than a simple piston, large transverse variations in sound pressure are anticipated in the vicinity of the source.- 1 October 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 118 (4) , 2405-2411
Comparison of an analytic horn equation approach and a boundary element method for the calculation of sound fields in the human ear canal
The sound field inside a model human ear canal has been computed, to show both longitudinal variations along the canal length and transverse variations through cross-sectional slices. Two methods of computation were used. A modified horn equation approach parametrizes the sound field with a single coordinate, the position along a curved center axis—this approach can accommodate the curvature and varying cross-sectional area of the ear canal but cannot compute transverse variations of the sound field. A boundary element method (BEM) was also implemented to compute the full three-dimensional sound field. Over 2000 triangular mesh elements were used to represent the ear canal geometry. For a plane piston source at the entrance plane, the pressure along the curved center axis predicted by the two methods is in good agreement, for frequencies up to , for four different ear canals. The BEM approach, though, reveals spatial variations of sound pressure within each canal cross section. These variations are small below , but increase with frequency, reaching at and at . For source configurations that are more realistic than a simple piston, large transverse variations in sound pressure are anticipated in the vicinity of the source.- 1 July 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 118 (1) , 205-212
Airflow noise in telephone handsets and methods for its reduction
The noise in a telephone handset produced by the bursts of airflow that accompany plosive sounds such as a “p” or “t” has been investigated. Measurements have been made on a series of modified handsets, using various arrangements of ports and tubes between microphone and the exterior of the telephone mouthpiece. A narrow stream of air was used to probe the mouthpiece and the signal picked up by the microphone recorded. The use of one, two, and multiple exterior holes was considered. Two-hole approaches alleviate the static pressure buildup that occurs when a single microphone hole is used and in many cases they result in reduced noise generation; for some directions of incident airflow, though, noise can be markedly increased. This was found to be due to interaction between intersecting streams of air. By using a large number of small (less than ) exterior holes, the airflow noise can be reduced by over for all incident directions of airflow. It is also beneficial to ensure that none of the exterior holes is in direct line with the sound tube leading to the microphone.- 1 July 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 118 (1) , 205-212
Airflow noise in telephone handsets and methods for its reduction
The noise in a telephone handset produced by the bursts of airflow that accompany plosive sounds such as a “p” or “t” has been investigated. Measurements have been made on a series of modified handsets, using various arrangements of ports and tubes between microphone and the exterior of the telephone mouthpiece. A narrow stream of air was used to probe the mouthpiece and the signal picked up by the microphone recorded. The use of one, two, and multiple exterior holes was considered. Two-hole approaches alleviate the static pressure buildup that occurs when a single microphone hole is used and in many cases they result in reduced noise generation; for some directions of incident airflow, though, noise can be markedly increased. This was found to be due to interaction between intersecting streams of air. By using a large number of small (less than ) exterior holes, the airflow noise can be reduced by over for all incident directions of airflow. It is also beneficial to ensure that none of the exterior holes is in direct line with the sound tube leading to the microphone.- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2618
Design and performance of a micro-probe microphone
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2618
Design and performance of a micro-probe microphone
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2618
Reduction of airflow noise in telephone handsets
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2618
Reduction of airflow noise in telephone handsets
- 16 April 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (5) , 1988-1992
Passive amplification and directivity from air-coupled surface waves generated above a structured ground
Peer reviewed: NoNRC publication: Ye
- 16 April 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (5) , 1988-1992
Passive amplification and directivity from air-coupled surface waves generated above a structured ground
Peer reviewed: NoNRC publication: Ye
- 27 February 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (3) , 1147-1156
Effect of handset proximity on hearing aid feedback
The increased sensitivity of hearing aids to feedback as a telephone handset is brought near has been studied experimentally and numerically. For the measurements, three different hearing aids were modified so that the open-loop transfer function could be measured. They were mounted in the pinna of a mannikin and the change in open-loop transfer function determined as a function of handset proximity. Increases of over 20 dB were observed, most of this change occurring within the first 10 mm of separation between pinna and handset. Numerical calculations performed using a boundary element technique were in good agreement with the measurements.
- 27 February 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (3) , 1147-1156
Effect of handset proximity on hearing aid feedback
The increased sensitivity of hearing aids to feedback as a telephone handset is brought near has been studied experimentally and numerically. For the measurements, three different hearing aids were modified so that the open-loop transfer function could be measured. They were mounted in the pinna of a mannikin and the change in open-loop transfer function determined as a function of handset proximity. Increases of over 20 dB were observed, most of this change occurring within the first 10 mm of separation between pinna and handset. Numerical calculations performed using a boundary element technique were in good agreement with the measurements.