Christine Qiong Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christine Qiong Wu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Nariman Sepehri
Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba R3T 5V6, Canada
3 shared publications - Nan Wu
Department of Mechanical Engineering, University of Manitoba, Winnipeg, Canada
2 shared publications - Samira Ahmadi
Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
2 shared publications - Tony Szturm
College of Rehabilitation Sciences, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
2 shared publications - Yun-Hsiang Sun
Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
2 shared publications - Anuprita Kanitkar
Department of Physical Therapy, College of Rehabilitation Sciences, University of Manitoba, Winnipeg, MB, Canada
1 shared publication
Latest Publications
- 30 May 2019
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 17 (6) , 1483-1493
Active Disturbance Rejection Control Applied to High-order Systems with Parametric Uncertainties
- 30 May 2019
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 17 (6) , 1483-1493
Active Disturbance Rejection Control Applied to High-order Systems with Parametric Uncertainties
- Open Access
Sample Entropy of Human Gait Center of Pressure Displacement: A Systematic Methodological Analysis
Sample entropy (SampEn) has been used to quantify the regularity or predictability of human gait signals. There are studies on the appropriate use of this measure for inter-stride spatio-temporal gait variables. However, the sensitivity of this measure to preprocessing of the signal and to variant values of template size (m), tolerance size (r), and sampling rate has not been studied when applied to “whole” gait signals. Whole gait signals are the entire time series data obtained from force or inertial sensors. This study systematically investigates the sensitivity of SampEn of the center of pressure displacement in the mediolateral direction (ML COP-D) to variant parameter values and two pre-processing methods. These two methods are filtering the high-frequency components and resampling the signals to have the same average number of data points per stride. The discriminatory ability of SampEn is studied by comparing treadmill walk only (WO) to dual-task (DT) condition. The results suggest that SampEn maintains the directional difference between two walking conditions across variant parameter values, showing a significant increase from WO to DT condition, especially when signals are low-pass filtered. Moreover, when gait speed is different between test conditions, signals should be low-pass filtered and resampled to have the same average number of data points per stride.
Open AccessSample Entropy of Human Gait Center of Pressure Displacement: A Systematic Methodological Analysis
Sample entropy (SampEn) has been used to quantify the regularity or predictability of human gait signals. There are studies on the appropriate use of this measure for inter-stride spatio-temporal gait variables. However, the sensitivity of this measure to preprocessing of the signal and to variant values of template size (m), tolerance size (r), and sampling rate has not been studied when applied to “whole” gait signals. Whole gait signals are the entire time series data obtained from force or inertial sensors. This study systematically investigates the sensitivity of SampEn of the center of pressure displacement in the mediolateral direction (ML COP-D) to variant parameter values and two pre-processing methods. These two methods are filtering the high-frequency components and resampling the signals to have the same average number of data points per stride. The discriminatory ability of SampEn is studied by comparing treadmill walk only (WO) to dual-task (DT) condition. The results suggest that SampEn maintains the directional difference between two walking conditions across variant parameter values, showing a significant increase from WO to DT condition, especially when signals are low-pass filtered. Moreover, when gait speed is different between test conditions, signals should be low-pass filtered and resampled to have the same average number of data points per stride.
- 1 December 2017
- Published by Canadian Science Publishing in Transactions of the Canadian Society for Mechanical Engineering
- Vol. 41 (5) , 669-680
EXPERIMENTAL STUDY ON BREATHING CRACK DETECTION AND EVALUATION UNDER RANDOM LOADING WITH ENTROPY
Breathing crack detection and evaluation on a beam under random loading is experimentally studied and realized using entropy measures. During testing, the beam is subjected to random excitations which is the most evident excitation type experienced by most of the engineering structures. Frequency response function is employed to erase the random frequency components due to the excitation from the response of the structure to pick up the vibration characteristics of the beam structure itself with/without the breathing crack. Based on experimental results, the proposed methodology can clearly discriminate a crack with 25% depth of the total thickness of the beam from the healthy case. It is also capable of distinguishing a 50% crack depth from a 25% crack depth with distinct entropy values.
- 1 December 2017
- Published by Canadian Science Publishing in Transactions of the Canadian Society for Mechanical Engineering
- Vol. 41 (5) , 669-680
EXPERIMENTAL STUDY ON BREATHING CRACK DETECTION AND EVALUATION UNDER RANDOM LOADING WITH ENTROPY
Breathing crack detection and evaluation on a beam under random loading is experimentally studied and realized using entropy measures. During testing, the beam is subjected to random excitations which is the most evident excitation type experienced by most of the engineering structures. Frequency response function is employed to erase the random frequency components due to the excitation from the response of the structure to pick up the vibration characteristics of the beam structure itself with/without the breathing crack. Based on experimental results, the proposed methodology can clearly discriminate a crack with 25% depth of the total thickness of the beam from the healthy case. It is also capable of distinguishing a 50% crack depth from a 25% crack depth with distinct entropy values.
- 31 October 2017
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (1)
The Effects of Aging and Dual Tasking on Human Gait Complexity During Treadmill Walking: A Comparative Study Using Quantized Dynamical Entropy and Sample Entropy
Quantized dynamical entropy (QDE) has recently been proposed as a new measure to quantify the complexity of dynamical systems with the purpose of offering a better computational efficiency. This paper further investigates the viability of this method using five different human gait signals. These signals are recorded while normal walking and while performing secondary tasks among two age groups (young and older age groups). The results are compared with the outcomes of previously established sample entropy (SampEn) measure for the same signals. We also study how analyzing segmented and spatially and temporally normalized signal differs from analyzing whole data. Our findings show that human gait signals become more complex as people age and while they are cognitively loaded. Center of pressure (COP) displacement in mediolateral direction is the best signal for showing the gait changes. Moreover, the results suggest that by segmenting data, more information about intrastride dynamical features are obtained. Most importantly, QDE is shown to be a reliable measure for human gait complexity analysis.
- 31 October 2017
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (1)
The Effects of Aging and Dual Tasking on Human Gait Complexity During Treadmill Walking: A Comparative Study Using Quantized Dynamical Entropy and Sample Entropy
Quantized dynamical entropy (QDE) has recently been proposed as a new measure to quantify the complexity of dynamical systems with the purpose of offering a better computational efficiency. This paper further investigates the viability of this method using five different human gait signals. These signals are recorded while normal walking and while performing secondary tasks among two age groups (young and older age groups). The results are compared with the outcomes of previously established sample entropy (SampEn) measure for the same signals. We also study how analyzing segmented and spatially and temporally normalized signal differs from analyzing whole data. Our findings show that human gait signals become more complex as people age and while they are cognitively loaded. Center of pressure (COP) displacement in mediolateral direction is the best signal for showing the gait changes. Moreover, the results suggest that by segmenting data, more information about intrastride dynamical features are obtained. Most importantly, QDE is shown to be a reliable measure for human gait complexity analysis.
- 25 March 2017
- Published by Techno-Press in Structural Monitoring and Maintenance
- Vol. 4 (1) , 33-52
Crack identification with parametric optimization of entropy & wavelet transformation
Crack identification with parametric optimization of entropy & wavelet transformation structural health monitoring;breathing cracks;crack identification;parametric optimization;sample entropy;wavelet transformation; A cantilever beam with a breathing crack is studied to improve the breathing crack identification sensitivity by the parametric optimization of sample entropy and wavelet transformation. Crack breathing is a special bi-linear phenomenon experienced by fatigue cracks which are under dynamic loadings. Entropy is a measure, which can quantify the complexity or irregularity in system dynamics, and hence employed to quantify the bi-linearity/irregularity of the vibration response, which is induced by the breathing phenomenon of a fatigue crack. To improve the sensitivity of entropy measurement for crack identification, wavelet transformation is merged with entropy. The crack identification is studied under different sinusoidal excitation frequencies of the cantilever beam. It is found that, for the excitation frequencies close to the first modal frequency of the beam structure, the method is capable of detecting only 22% of the crack depth percentage ratio with respect to the thickness of the beam. Using parametric optimization of sample entropy and wavelet transformation, this crack identification sensitivity is improved up to 8%. The experimental studies are carried out, and experimental results successfully validate the numerical parametric optimization process.
- 25 March 2017
- Published by Techno-Press in Structural Monitoring and Maintenance
- Vol. 4 (1) , 33-52
Crack identification with parametric optimization of entropy & wavelet transformation
Crack identification with parametric optimization of entropy & wavelet transformation structural health monitoring;breathing cracks;crack identification;parametric optimization;sample entropy;wavelet transformation; A cantilever beam with a breathing crack is studied to improve the breathing crack identification sensitivity by the parametric optimization of sample entropy and wavelet transformation. Crack breathing is a special bi-linear phenomenon experienced by fatigue cracks which are under dynamic loadings. Entropy is a measure, which can quantify the complexity or irregularity in system dynamics, and hence employed to quantify the bi-linearity/irregularity of the vibration response, which is induced by the breathing phenomenon of a fatigue crack. To improve the sensitivity of entropy measurement for crack identification, wavelet transformation is merged with entropy. The crack identification is studied under different sinusoidal excitation frequencies of the cantilever beam. It is found that, for the excitation frequencies close to the first modal frequency of the beam structure, the method is capable of detecting only 22% of the crack depth percentage ratio with respect to the thickness of the beam. Using parametric optimization of sample entropy and wavelet transformation, this crack identification sensitivity is improved up to 8%. The experimental studies are carried out, and experimental results successfully validate the numerical parametric optimization process.
- 14 July 2016
- Published by Springer Nature in International Journal of Mechanics and Materials in Design
- Vol. 13 (3) , 469-480
Extensions of the U* theory for applications on orthotropic composites and nonlinear elastic materials
- 14 July 2016
- Published by Springer Nature in International Journal of Mechanics and Materials in Design
- Vol. 13 (3) , 469-480
Extensions of the U* theory for applications on orthotropic composites and nonlinear elastic materials
- 23 October 2015
- Published by ASME International in Journal of Computational and Nonlinear Dynamics
- Vol. 11 (3) , 031009
Comparison of Four Friction Models: Feature Prediction
In this paper, we provide not only key knowledge for friction model selection among candidate models but also experimental friction features compared with numerical predictions reproduced by the candidate models. A motor-driven one-dimensional sliding block has been designed and fabricated in our lab to carry out a wide range of control tasks for the friction feature demonstrations and the parameter identifications of the candidate models. Besides the well-known static features such as break-away force and viscous friction, our setup experimentally demonstrates subtle dynamic features that characterize the physical behavior. The candidate models coupled with correct parameters experimentally obtained from our setup are taken to simulate the features of interest. The first part of this work briefly introduces the candidate friction models, the friction features of interest, and our experimental approach. The second part of this work is dedicated to the comparisons between the experimental features and the numerical model predictions. The discrepancies between the experimental features and the numerical model predictions help researchers to judge the accuracy of the models. The relation between the candidate model structures and their numerical friction feature predictions is investigated and discussed. A table that summarizes how to select the most optimal friction model among a variety of engineering applications is presented at the end of this paper. Such comprehensive comparisons have not been reported in previous literature.
- 23 October 2015
- Published by ASME International in Journal of Computational and Nonlinear Dynamics
- Vol. 11 (3) , 031009
Comparison of Four Friction Models: Feature Prediction
In this paper, we provide not only key knowledge for friction model selection among candidate models but also experimental friction features compared with numerical predictions reproduced by the candidate models. A motor-driven one-dimensional sliding block has been designed and fabricated in our lab to carry out a wide range of control tasks for the friction feature demonstrations and the parameter identifications of the candidate models. Besides the well-known static features such as break-away force and viscous friction, our setup experimentally demonstrates subtle dynamic features that characterize the physical behavior. The candidate models coupled with correct parameters experimentally obtained from our setup are taken to simulate the features of interest. The first part of this work briefly introduces the candidate friction models, the friction features of interest, and our experimental approach. The second part of this work is dedicated to the comparisons between the experimental features and the numerical model predictions. The discrepancies between the experimental features and the numerical model predictions help researchers to judge the accuracy of the models. The relation between the candidate model structures and their numerical friction feature predictions is investigated and discussed. A table that summarizes how to select the most optimal friction model among a variety of engineering applications is presented at the end of this paper. Such comprehensive comparisons have not been reported in previous literature.
- 17 October 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (12) , 121002
Using Entropy Measures to Characterize Human Locomotion
Entropy measures have been widely used to quantify the complexity of theoretical and experimental dynamical systems. In this paper, the value of using entropy measures to characterize human locomotion is demonstrated based on their construct validity, predictive validity in a simple model of human walking and convergent validity in an experimental study. Results show that four of the five considered entropy measures increase meaningfully with the increased probability of falling in a simple passive bipedal walker model. The same four entropy measures also experienced statistically significant increases in response to increasing age and gait impairment caused by cognitive interference in an experimental study. Of the considered entropy measures, the proposed quantized dynamical entropy (QDE) and quantization-based approximation of sample entropy (QASE) offered the best combination of sensitivity to changes in gait dynamics and computational efficiency. Based on these results, entropy appears to be a viable candidate for assessing the stability of human locomotion.
- 17 October 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (12) , 121002
Using Entropy Measures to Characterize Human Locomotion
Entropy measures have been widely used to quantify the complexity of theoretical and experimental dynamical systems. In this paper, the value of using entropy measures to characterize human locomotion is demonstrated based on their construct validity, predictive validity in a simple model of human walking and convergent validity in an experimental study. Results show that four of the five considered entropy measures increase meaningfully with the increased probability of falling in a simple passive bipedal walker model. The same four entropy measures also experienced statistically significant increases in response to increasing age and gait impairment caused by cognitive interference in an experimental study. Of the considered entropy measures, the proposed quantized dynamical entropy (QDE) and quantization-based approximation of sample entropy (QASE) offered the best combination of sensitivity to changes in gait dynamics and computational efficiency. Based on these results, entropy appears to be a viable candidate for assessing the stability of human locomotion.
- 9 July 2014
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 136 (5) , 054504
On Constrained and Energy Efficient Balance Control of a Standing Biped: Experimentation and Stability Analysis
Balancing control is important for biped standing. In spite of large efforts, it is very difficult to design balancing control strategies satisfying three requirements simultaneously: maintaining postural stability, improving energy efficiency, and satisfying the constraints between the biped feet and the ground. To implement such a control, inclusion of the actuators' dynamics is necessary, which complicates the overall system, obstructs the control design, and makes stability analysis more difficult. In this paper, a constrained balancing control meeting all three requirements is designed for a standing bipedal robot. The dynamics of the selected actuators has been considered for developing the motion equations of the overall control system, which has usually been neglected in simulations. In addition, stability analysis of such a complex biped control system has been provided using the concept of Lyapunov exponents (LEs), which shows the significance of actuators' dynamics on the stability region. The paper contributes to balancing standing biped in both the theoretical and the practical sense.
- 9 July 2014
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 136 (5) , 054504
On Constrained and Energy Efficient Balance Control of a Standing Biped: Experimentation and Stability Analysis
Balancing control is important for biped standing. In spite of large efforts, it is very difficult to design balancing control strategies satisfying three requirements simultaneously: maintaining postural stability, improving energy efficiency, and satisfying the constraints between the biped feet and the ground. To implement such a control, inclusion of the actuators' dynamics is necessary, which complicates the overall system, obstructs the control design, and makes stability analysis more difficult. In this paper, a constrained balancing control meeting all three requirements is designed for a standing bipedal robot. The dynamics of the selected actuators has been considered for developing the motion equations of the overall control system, which has usually been neglected in simulations. In addition, stability analysis of such a complex biped control system has been provided using the concept of Lyapunov exponents (LEs), which shows the significance of actuators' dynamics on the stability region. The paper contributes to balancing standing biped in both the theoretical and the practical sense.