OJOve Jonsson

Ove Jonsson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ove Jonsson has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Ann-Charlott Steffen

    Global DMPK, In Vivo Screening & Profiling, AstraZeneca R&D, SE-15185, Södertälje, Sweden

    1 shared publication
  • Anna Breitholtz Emanuelsson

    Med CNS & Pain, DMPK, AstraZeneca R&D, SE-15185, Södertälje, Sweden

    1 shared publication
  • Juliette Janson

    Med CNS & Pain, DMPK, AstraZeneca R&D, SE-15185, Södertälje, Sweden

    1 shared publication
  • Kristian Königsson

    Global Safety Assessment, AstraZeneca R&D, Södertälje, Sweden

    1 shared publication
  • Lars B Nilsson

    Global DMPK, Regulatory Bioanalysis, AstraZeneca R&D, Mölndal, Sweden

    1 shared publication
  • Marie Eriksson

    Global Safety Assessment, AstraZeneca R&D, Södertälje, Sweden

    1 shared publication

Latest Publications

  • Capillary Microsampling and Analysis of 4-µL Blood, Plasma and Serum Samples to Determine Human α-Synuclein Elimination Rate in Mice

    by Ove Jonsson, Ann-Charlott Steffen, Valentina Screpanti Sundquist, Juliette Janson, Stefan Martinsson, Ulrika Määttä, Anna Breitholtz Emanuelsson

    The capillary microsampling technique was scaled down to enable repeated PK sampling of blood, plasma and serum from mice for the determination of the 14-kDa protein α-synuclein using the Gyrolab™ immunoassay platform. 4-µl plasma, serum or blood samples were taken from 36 mice, in total 648 samples were successfully collected and analyzed. Following intravenous administration of human α-synuclein to mice, the elimination of α-synuclein was rapid, with a half-life in plasma of 1.1 h. High endogenous levels in red blood cells in combination with some hemolysis led to a challenge in the evaluation of α-synuclein exposure in plasma and serum. The small sample volumes and flexibility in choice of liquid matrices using the capillary microsampling technique enable repeated sampling in mouse studies, as well as multi-matrix analysis if needed. Liquid microsampling is well suited for micro- and nano-liter scale immunoassays.


  • Validation of A Bioanalytical Method Using Capillary Microsampling of 8 µL Plasma Samples: Application to A Toxicokinetic Study in Mice

    by Ove Jonsson, Rodrigo Palma Villar, Lars B Nilsson, Marie Eriksson, Kristian Königsson

    Capillary microsampling was recently introduced as a new technique for simplified collection and handling of small, exact volumes of liquid matrices. In this article, a bioanalytical method was developed and fully validated for 8 µl plasma samples and applied to a toxicology study in mice. The method was validated in the concentration range 0.06-30 µM. A procedure where 32 µl of blood was collected for preparation of 8 µl plasma was successfully implemented at the animal facility. All the results for the method and study validation met the requirements of a regulated assay. It is shown that 8 µl plasma microsamples can be sampled and analyzed with consistently excellent accuracy and precision. Capillary microsampling of plasma offers a possibility to combine ethical, scientific and economic benefits while still maintaining the advantage of having drug exposure data in plasma.