TDTomáš Dlouhý

Tomáš Dlouhý

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tomáš Dlouhý has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Combustion Air Humidifier for a Biomass Boiler with Flue Gas Condensation

    by Jan Havlík, Tomáš Dlouhý

    This paper deals with combustion air humidification for application with a biomass boiler and a spray flue gas condenser. The use of a combustion air humidifier increases the dew point temperature of the flue gas, thereby increasing the potential for heat recovery in the flue gas condenser and increasing the amount of heat supplied to the thermal system. The air humidification process in a counter current spray humidifier was experimentally analysed under conditions corresponding to the use before a biomass boiler with a flue gas condenser. For air heating and humidification, temperature factor values of up to 0.90 can be obtained; this value is mainly influenced by the ratio of the spray water and humidified air flow rates. The volumetric heat transfer coefficient is significantly affected by the humidified air velocity, although this velocity is negligible compared to the counter current spray water velocity. The volumetric heat transfer coefficient reaches higher values at higher spray water temperatures and therefore higher air heating. The whole process is also affected by the saturation of the incoming air, where the dew point temperature of the air drawn in from the surroundings is lower than its temperature. These results can be used as basic information for the design of combustion air humidifiers, for the selection of their operating parameters, and for a basic balancing of the energy contribution of the combustion air humidifier before a more detailed design of the whole system.

  • Open Access

    Overview of calculation methods for determining the heat transfer coefficient for condensation of flue gas from biomass boilers in vertical tube condensers

    by Jakub Krempaský, Jan Havlík, Tomáš Dlouhý

    The condensation of water vapor from flue gas in the energy cycles of power and heating plants is an important issue to increase the efficiency of the boiler or to separate water vapor from flue gas. A theoretical study of flue gas condensation from biomass boilers in vertical tube condensers was conducted. An overview of the methods available for determining the condensation heat transfer coefficient was compiled. Three approaches were identified to determine the heat transfer coefficient and condenser heat output according to the foundation of each method: experimental foundation (Empirical correlations), semi-theoretical foundation (Heat and mass transfer analogy, Diffusion layer model) and theoretical foundation (Boundary layer model). Empirical correlations represent the simplest way to predict the condensation heat transfer coefficient. However, the deviation of the predicted results from the experimental results is quite high, and since the equations usually lack some important driving parameters or are developed for a slightly different geometry of operating conditions, they are not reliable enough for the considered application. The Boundary layer model is very complex and impractical. Therefore, the use of the Heat and mass transfer analogy or the Diffusion layer model is the most effective for the mentioned application.


  • Open Access

    Comparison of Theoretical Methods Describing the Heat Transfer in Vertical Tube Condensers Under Conditions Corresponding to the Condensation of Flue Gas From a Biomass Boiler

    by Jakub Krempaský, Jan Havlík, Tomáš Dlouhý

    A theoretical and experimental study was conducted on the condensation of water vapor in a vertical tube condenser under conditions corresponding to the condensation of flue gas from a biomass boiler, where flue gas is considered a mixture of water vapor and a high content of noncondensable gas (NCG). Four fundamental theoretical methods were identified for determining the heat transfer coefficient and condenser heat output—empirical correlations, heat and mass transfer analogy, diffusion layer theory, and boundary layer theory. These methods were compared in terms of their usability in the design of flue gas condensers in energy systems and experimentally verified. Experiments were carried out in a 1.5 m long vertical double-pipe condenser with a condensing gas flowing in a downward direction through an inner tube with a diameter of 25 mm. The mass concentration of NCG in a mixture with water vapor ranged from 11 vol% to 86 vol% and the inlet Reynolds number of the condensing gas ranged from 1936 to 14,408, which corresponds with the conditions of condensing flue gas from biomass boilers. The boundary layer theory is highly complex and impractical for the calculation of heat exchangers. Empirical correlations have a wide dispersion of the result, because they consider only the fundamental parameters of the process. Nevertheless, heat and mass transfer analogy and diffusion layer theory seem to be the most suitable for flue gas condensers since they capture the physical essence of the phenomena.


  • Open Access

    Heat Transfer in Double Pipe Heat Exchangers With Small Tube Spacing

    by Jan Havlík, Tomáš Dlouhý, Jakub Krempaský

    In this work, the heat transfer in double pipe heat exchangers (DPHEs) with small tube spacing is analyzed. This type of heat transfer is generally described in many literary sources; however, in laminar flow, the resulting values of the theoretical equations differ. Moreover, the small spacing of the pipes can affect the fluid flow and subsequent heat transfer. The suitability of using available theoretical methods for the design of double pipe heat exchangers (the Stephan, VDI, and Baehr methods) was evaluated. A series of experiments was carried out on a double pipe heat exchanger with a tube spacing of 1.4 mm. The experimentally determined value of the heat transfer coefficient (HTC) was up to two times higher in comparison with the values calculated according to theoretical methods. The relative increase was more significant for the lower Reynolds number values. At the same time, the difference of the wall temperature along the circumference of the outer tube was detected. This phenomenon was theoretically analyzed and can be explained by tube misalignment in the small tube spacing. The procedure of quantification of this effect was proposed. This effect may cause an inhomogeneity of the media flow and temperature distribution and, as a result, increase the performance of the heat exchanger by tens of percent.


  • Open Access

    Analysis of parameters important for indirect drying of biomass fuel

    by Michel Sabatini, Jan Havlík, Tomáš Dlouhý

    This paper focuses on biomass drying for the design and operation of an indirect dryer used in a biomass power plant. Indirect biomass drying is not as well described process as direct drying, especially when used for the preparation of biomass in energy processes, such as combustion or gasification. Therefore, it is necessary to choose a suitable model describing the drying process and evaluate its applicability for this purpose. The aim of this paper is to identify parameters that most significantly affect the indirect drying process of biomass for precise targeting of future experiments. For this purpose, the penetration model was chosen. The penetration model describes indirect drying through 21 parameters. To run a series of experiments focused on all parameters would be time consuming. Therefore, the easier way is to select the most important parameters through a sensitivity analysis, and then perform experiments focused only on the significant parameters The parameters evaluated as significant are the temperature of the heated wall, operating pressure in the drying chamber, surface coverage factor, emissivity of the heated wall, emissivity of the bed, diameter of the particle, and particle surface roughness. Due to the presumption of perfect mixing of the material being dried, stirrer speed is added into important parameters. Based on these findings, it will be possible to reduce the scope of experiments necessary to verify the applicability of the penetration model for the description of indirect biomass drying and the design of dryers for a practical use.

  • Open Access

    Drying Biomass with a High Water Content—The Influence of the Final Degree of Drying on the Sizing of Indirect Dryers

    by Jan Havlík, Tomáš Dlouhý, Ján Pitel’

    This article deals with the influence of the final drying degree of moist biomass used as fuel in a power or CHP plant on indirect dryer sizing. For a description of the drying process, experiments with wet bark containing approx. 50 wt% of water were carried out in a laboratory indirect dryer. A new parameter called drying effectivity was introduced, whose size varies according to the degree of biomass being dried. Its maximum value corresponds to the optimal biomass drying, when the relative size of the indirect dryer to evaporate the required mass of water from the biomass would be smallest. Based on the experimentally determined drying characteristics of wet bark, the optimal drying of 13 wt% of water content was evaluated. If the bark was dried to a lower water content, the required relative size and price of the dryer would increase. Similarly, drying a bark with water content above 31 wt% is not very advantageous because drying effectivity continues to increase rapidly at this stage, and the required relative size of the dryer therefore decreases.


  • Open Access

    Indirect Dryers for Biomass Drying—Comparison of Experimental Characteristics for Drum and Rotary Configurations

    by Jan Havlík, Tomáš Dlouhý

    This paper focuses on indirect biomass drying. It compares the operating characteristics of a laboratory-scale drum dryer and a pilot-scale rotary dryer. Before the design of an industrial dryer for a specific material, it is important to experimentally prove the process and to determine the drying characteristics of the material. To verify the portability of experimental results for indirect dryers, a drum dryer with indirect electric heating in a laboratory scale was designed and built to test and study the process of indirect drying. Based on the results obtained on a small-scale device, a prototype of a pilot steam-heated rotary dryer was designed and manufactured. A broad range of experiments with green wood chips and wet bark from open-air storage with moisture contents of 50 to 65 wt % were carried out on both dryers. The drying curves indicating the process, the square and volumetric evaporation capacities, and the drying energy consumption were obtained and compared, and the feasibility of indirect drying for these tested types of biomass was confirmed.


  • Contributor contact details

    by D. Roddy, J. Fadok, A.D. Rao, Y. Zhu, H.C. Frey, B. Dooley, R. Svoboda, S.J. Doong, A. Basile, F. Gallucci, et al.