David Simons
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Simons has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Heinz-Peter Schlemmer
Department of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
2 shared publicationsKathrin Yen
Institute of Forensic Medicine, University Hospital of Heidelberg, Voßstraße 2, 69115, Heidelberg, Germany
2 shared publicationsAlina Sassenberg
Institute of Forensic Medicine, University of Heidelberg, Heidelberg 69115, Germany
1 shared publicationAnna Heger
Institute of Forensic Medicine, University Hospital of Heidelberg, Voßstraße 2, 69115, Heidelberg, Germany
1 shared publicationAstrid Krauskopf
Institute of Forensic Medicine, University Hospital of Heidelberg, Voßstraße 2, 69115, Heidelberg, Germany
1 shared publication- Francesco Pisana
Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, 69120, Germany
1 shared publication
Latest Publications
- 22 July 2016
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (2) , 489-496
New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment
Purpose The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Materials and methods Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as “unfolding” visualizations of the rib cage (modality C, “eagle tool”). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Results Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Conclusion Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.
- 22 July 2016
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (2) , 489-496
New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment
Purpose The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Materials and methods Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as “unfolding” visualizations of the rib cage (modality C, “eagle tool”). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Results Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Conclusion Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.
- Open Access
- 21 June 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-8
Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose
Dual energy CT (DECT) has proven its potential in oncological imaging. Considering the repeated follow-up examinations, radiation dose should not exceed conventional single energy CT (SECT). Comparison studies on the same scanner with a large number of patients, considering patient geometries and image quality, and exploiting full potential of SECT dose reduction are rare. Purpose of this retrospective study was to compare dose of dual source DECT versus dose-optimized SECT abdominal imaging in clinical routine. One hundred patients (62y (±14)) had either contrast-enhanced SECT including automatic voltage control (44) or DECT (56). CT dose index (CTDIvol), size-specific dose-estimate (SSDE) and dose-length product (DLP) were reported. Image noise (SD) was recorded as mean of three ROIs placed in subcutaneous fat and normalized to dose by $$ SDn=SD\times \sqrt{CDTIvol} $$ . For dose-normalized contrast-to-noise ratio (CNRD), mean attenuation of psoas muscle (CTmuscle) and subcutaneous fat (CTfat) were compared by CNRD = (CTmuscle − CTfat)/SDn. Statistical significance was tested with two-sided t-test (α = 0.05). There was no significant difference (p < 0.05) between DECT and SECT: Mean CTDIvol was 14.2 mGy (±3.9) (DECT) and 14.3 mGy (±4.5) (SECT). Mean DLP was 680 mGy*cm (±220) (DECT) and 665 mGy*cm (±231) (SECT). Mean SSDE was 15.7 mGy (±1.9) (DECT) and 16.1 mGy (±2.5) (SECT). Mean SDn was 42.2 (±13.9) HU $$ *\sqrt{\mathrm{mGy}} $$ (DECT) and 47.8 (±14.9) HU $$ *\sqrt{\mathrm{mGy}} $$ (SECT). Mean CNRD was 3.9 (±1.3) $$ {\mathrm{mGy}}^{-\frac{1}{2}} $$ . (DECT) and 4.0 (±1.3) $$ {\mathrm{mGy}}^{-\frac{1}{2}} $$ (SECT). Abdominal DECT is feasible without increasing radiation dose or deteriorating image quality, even compared to dose-optimized SECT including automatic voltage control. Thus DECT can contribute to sophisticated oncological imaging without dose penalty.- 21 June 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-8
Open AccessAdvanced abdominal imaging with dual energy CT is feasible without increasing radiation dose
Dual energy CT (DECT) has proven its potential in oncological imaging. Considering the repeated follow-up examinations, radiation dose should not exceed conventional single energy CT (SECT). Comparison studies on the same scanner with a large number of patients, considering patient geometries and image quality, and exploiting full potential of SECT dose reduction are rare. Purpose of this retrospective study was to compare dose of dual source DECT versus dose-optimized SECT abdominal imaging in clinical routine. One hundred patients (62y (±14)) had either contrast-enhanced SECT including automatic voltage control (44) or DECT (56). CT dose index (CTDIvol), size-specific dose-estimate (SSDE) and dose-length product (DLP) were reported. Image noise (SD) was recorded as mean of three ROIs placed in subcutaneous fat and normalized to dose by $$ SDn=SD\times \sqrt{CDTIvol} $$ . For dose-normalized contrast-to-noise ratio (CNRD), mean attenuation of psoas muscle (CTmuscle) and subcutaneous fat (CTfat) were compared by CNRD = (CTmuscle − CTfat)/SDn. Statistical significance was tested with two-sided t-test (α = 0.05). There was no significant difference (p < 0.05) between DECT and SECT: Mean CTDIvol was 14.2 mGy (±3.9) (DECT) and 14.3 mGy (±4.5) (SECT). Mean DLP was 680 mGy*cm (±220) (DECT) and 665 mGy*cm (±231) (SECT). Mean SSDE was 15.7 mGy (±1.9) (DECT) and 16.1 mGy (±2.5) (SECT). Mean SDn was 42.2 (±13.9) HU $$ *\sqrt{\mathrm{mGy}} $$ (DECT) and 47.8 (±14.9) HU $$ *\sqrt{\mathrm{mGy}} $$ (SECT). Mean CNRD was 3.9 (±1.3) $$ {\mathrm{mGy}}^{-\frac{1}{2}} $$ . (DECT) and 4.0 (±1.3) $$ {\mathrm{mGy}}^{-\frac{1}{2}} $$ (SECT). Abdominal DECT is feasible without increasing radiation dose or deteriorating image quality, even compared to dose-optimized SECT including automatic voltage control. Thus DECT can contribute to sophisticated oncological imaging without dose penalty. - Open Access
- 2 October 2015
- Published by Springer Nature in Cancer Imaging
- Vol. 15 (S1) , P51
Dual-energy CT in oncology: technical principles and clinical prospects
- 2 October 2015
- Published by Springer Nature in Cancer Imaging
- Vol. 15 (S1) , P51
Open AccessDual-energy CT in oncology: technical principles and clinical prospects
- Open Access
- 1 January 2014
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 15 (2) , 205-209
Forensic Imaging for Causal Investigation of Death
Simons D, et al. Korean J Radiol. 2014 Mar-Apr;15(2):205-209. http://dx.doi.org/10.3348/kjr.2014.15.2.205
- 1 January 2014
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 15 (2) , 205-209
Open AccessForensic Imaging for Causal Investigation of Death
Simons D, et al. Korean J Radiol. 2014 Mar-Apr;15(2):205-209. http://dx.doi.org/10.3348/kjr.2014.15.2.205