Emmanuelle Trévisiol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emmanuelle Trévisiol has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Christophe Vieu
Laboratory for Analysis and Architecture of Systems (LAAS-CNRS), Université de Toulouse, CNRS, INSA, Toulouse, France
4 shared publicationsChristophe Thibault
LAAS-CNRS, Université de Toulouse, CNRS, INSA, UPS, Toulouse, France
3 shared publications- Christophe Vieu
CNRS, LAAS, 7 avenue du colonel Roche, F-31077 Toulouse, France
2 shared publications Franck Carcenac
LAAS-CNRS, Université de Toulouse, CNRS, INSA, UPS, Toulouse, France
2 shared publications- Laurent Malaquin
LAAS-CNRS
2 shared publications Amélie Degache
INNOPSYS, Carbonne, France
1 shared publication
Latest Publications
- Open Access
Cell Aggregate Assembly through Microengineering for Functional Tissue Emergence
Compared to cell suspensions or monolayers, 3D cell aggregates provide cellular interactions organized in space and heterogeneity that better resume the real organization of native tissues. They represent powerful tools to narrow down the gap between in vitro and in vivo models, thanks to their self-evolving capabilities. Recent strategies have demonstrated their potential as building blocks to generate microtissues. Developing specific methodologies capable of organizing these cell aggregates into 3D architectures and environments has become essential to convert them into functional microtissues adapted for regenerative medicine or pharmaceutical screening purposes. Although the techniques for producing individual cell aggregates have been on the market for over a decade, the methodology for engineering functional tissues starting from them is still a young and quickly evolving field of research. In this review, we first present a panorama of emerging cell aggregates microfabrication and assembly technologies. We further discuss the perspectives opened in the establishment of functional tissues with a specific focus on controlled architecture and heterogeneity to favor cell differentiation and proliferation.
Open AccessCell Aggregate Assembly through Microengineering for Functional Tissue Emergence
Compared to cell suspensions or monolayers, 3D cell aggregates provide cellular interactions organized in space and heterogeneity that better resume the real organization of native tissues. They represent powerful tools to narrow down the gap between in vitro and in vivo models, thanks to their self-evolving capabilities. Recent strategies have demonstrated their potential as building blocks to generate microtissues. Developing specific methodologies capable of organizing these cell aggregates into 3D architectures and environments has become essential to convert them into functional microtissues adapted for regenerative medicine or pharmaceutical screening purposes. Although the techniques for producing individual cell aggregates have been on the market for over a decade, the methodology for engineering functional tissues starting from them is still a young and quickly evolving field of research. In this review, we first present a panorama of emerging cell aggregates microfabrication and assembly technologies. We further discuss the perspectives opened in the establishment of functional tissues with a specific focus on controlled architecture and heterogeneity to favor cell differentiation and proliferation.
- 10 April 2018
- Published by Springer Nature
- Vol. 1771, 83-95
Fabrication of Biomolecule Microarrays for Cell Immobilization Using Automated Microcontact Printing
Biomolecule microarrays are generally produced by conventional microarrayer, i.e., by contact or inkjet printing. Microcontact printing represents an alternative way of deposition of biomolecules on solid supports but even if various biomolecules have been successfully microcontact printed, the production of biomolecule microarrays in routine by microcontact printing remains a challenging task and needs an effective, fast, robust, and low-cost automation process. Here, we describe the production of biomolecule microarrays composed of extracellular matrix protein for the fabrication of cell microarrays by using an automated microcontact printing device. Large scale cell microarrays can be reproducibly obtained by this method.
- 10 April 2018
- Published by Springer Nature
- Vol. 1771, 83-95
Fabrication of Biomolecule Microarrays for Cell Immobilization Using Automated Microcontact Printing
Biomolecule microarrays are generally produced by conventional microarrayer, i.e., by contact or inkjet printing. Microcontact printing represents an alternative way of deposition of biomolecules on solid supports but even if various biomolecules have been successfully microcontact printed, the production of biomolecule microarrays in routine by microcontact printing remains a challenging task and needs an effective, fast, robust, and low-cost automation process. Here, we describe the production of biomolecule microarrays composed of extracellular matrix protein for the fabrication of cell microarrays by using an automated microcontact printing device. Large scale cell microarrays can be reproducibly obtained by this method.
- 4 July 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (3) , 60
Integration of solid-state nanopores into a functional device designed for electrical and optical cross-monitoring
We present a new strategy for fabricating a silicon nanopore device allowing straightforward fluidic integration and electrical as well as optical monitoring. The device presents nanopores of diameters 10 nm to 160 nm, and could therefore be used to obtain solvent-free free-standing lipid bilayers from small unilamellar vesicles (SUV) or large unilamellar vesicles (LUV). The silicon chip fabrication process only requires front side processing of a silicon-on-insulator (SOI) substrate. A polydimethylsiloxane (PDMS) microfluidic interface is assembled on the silicon chip for fluidic handling and electrical addressing. We detail the electrical specifications of our device and some perspectives showing that the use of an SOI substrate is a convenient way to reduce the electrical noise in a silicon nanopore device without the need of a photolitographic patterned passivation layer. We then demonstrate simultaneous electrical and optical monitoring by capturing negatively charged fluorescent nanoparticles. Finally, in the perspective of solvent-free free-standing lipid bilayers, we show that incubation of SUV results in a drastic increase of the device electrical resistance, which is likely due to the formation of a free-standing lipid bilayer sealing the nanopores.
- 4 July 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (3) , 60
Integration of solid-state nanopores into a functional device designed for electrical and optical cross-monitoring
We present a new strategy for fabricating a silicon nanopore device allowing straightforward fluidic integration and electrical as well as optical monitoring. The device presents nanopores of diameters 10 nm to 160 nm, and could therefore be used to obtain solvent-free free-standing lipid bilayers from small unilamellar vesicles (SUV) or large unilamellar vesicles (LUV). The silicon chip fabrication process only requires front side processing of a silicon-on-insulator (SOI) substrate. A polydimethylsiloxane (PDMS) microfluidic interface is assembled on the silicon chip for fluidic handling and electrical addressing. We detail the electrical specifications of our device and some perspectives showing that the use of an SOI substrate is a convenient way to reduce the electrical noise in a silicon nanopore device without the need of a photolitographic patterned passivation layer. We then demonstrate simultaneous electrical and optical monitoring by capturing negatively charged fluorescent nanoparticles. Finally, in the perspective of solvent-free free-standing lipid bilayers, we show that incubation of SUV results in a drastic increase of the device electrical resistance, which is likely due to the formation of a free-standing lipid bilayer sealing the nanopores.
- Open Access
Automated and Multiplexed Soft Lithography for the Production of Low-Density DNA Microarrays
Microarrays are established research tools for genotyping, expression profiling, or molecular diagnostics in which DNA molecules are precisely addressed to the surface of a solid support. This study assesses the fabrication of low-density oligonucleotide arrays using an automated microcontact printing device, the InnoStamp 40®. This automate allows a multiplexed deposition of oligoprobes on a functionalized surface by the use of a MacroStampTM bearing 64 individual pillars each mounted with 50 circular micropatterns (spots) of 160 µm diameter at 320 µm pitch. Reliability and reuse of the MacroStampTM were shown to be fast and robust by a simple washing step in 96% ethanol. The low-density microarrays printed on either epoxysilane or dendrimer-functionalized slides (DendriSlides) showed excellent hybridization response with complementary sequences at unusual low probe and target concentrations, since the actual probe density immobilized by this technology was at least 10-fold lower than with the conventional mechanical spotting. In addition, we found a comparable hybridization response in terms of fluorescence intensity between spotted and printed oligoarrays with a 1 nM complementary target by using a 50-fold lower probe concentration to produce the oligoarrays by the microcontact printing method. Taken together, our results lend support to the potential development of this multiplexed microcontact printing technology employing soft lithography as an alternative, cost-competitive tool for fabrication of low-density DNA microarrays.
Open AccessAutomated and Multiplexed Soft Lithography for the Production of Low-Density DNA Microarrays
Microarrays are established research tools for genotyping, expression profiling, or molecular diagnostics in which DNA molecules are precisely addressed to the surface of a solid support. This study assesses the fabrication of low-density oligonucleotide arrays using an automated microcontact printing device, the InnoStamp 40®. This automate allows a multiplexed deposition of oligoprobes on a functionalized surface by the use of a MacroStampTM bearing 64 individual pillars each mounted with 50 circular micropatterns (spots) of 160 µm diameter at 320 µm pitch. Reliability and reuse of the MacroStampTM were shown to be fast and robust by a simple washing step in 96% ethanol. The low-density microarrays printed on either epoxysilane or dendrimer-functionalized slides (DendriSlides) showed excellent hybridization response with complementary sequences at unusual low probe and target concentrations, since the actual probe density immobilized by this technology was at least 10-fold lower than with the conventional mechanical spotting. In addition, we found a comparable hybridization response in terms of fluorescence intensity between spotted and printed oligoarrays with a 1 nM complementary target by using a 50-fold lower probe concentration to produce the oligoarrays by the microcontact printing method. Taken together, our results lend support to the potential development of this multiplexed microcontact printing technology employing soft lithography as an alternative, cost-competitive tool for fabrication of low-density DNA microarrays.
- 1 August 2015
- Published by Elsevier in Microelectronic Engineering
- Vol. 144, 57-60
Controlled sealing of nanopores using an easily fabricated silicon platform combining in situ optical and electrical monitoring
- 1 August 2015
- Published by Elsevier in Microelectronic Engineering
- Vol. 144, 57-60
Controlled sealing of nanopores using an easily fabricated silicon platform combining in situ optical and electrical monitoring
- 11 March 2014
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (11) , 3132-3141
Preparation of Tethered-Lipid Bilayers on Gold Surfaces for the Incorporation of Integral Membrane Proteins Synthesized by Cell-Free Expression
There is an increasing interest to express and study membrane proteins in vitro. New techniques to produce and insert functional membrane proteins into planar lipid bilayers have to be developed. In this work, we produce a tethered lipid bilayer membrane (tBLM) to provide sufficient space for the incorporation of the integral membrane protein (IMP) Aquaporin Z (AqpZ) between the tBLM and the surface of the sensor. We use a gold (Au)-coated sensor surface compatible with mechanical sensing using a quartz crystal microbalance with dissipation monitoring (QCM-D) or optical sensing using the surface plasmon resonance (SPR) method. tBLM is produced by vesicle fusion onto a thin gold film, using phospholipid-polyethylene glycol (PEG) as a spacer. Lipid vesicles are composed of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-poly(ethyleneglycol)-2000-N-[3-(2-pyridyldithio)propionate], so-called DSPE-PEG-PDP, at different molar ratios (respectively, 99.5/0.5, 97.5/2.5, and 95/5 mol %), and tBLM formation is characterized using QCM-D, SPR, and atomic force technology (AFM). We demonstrate that tBLM can be produced on the gold surface after rupture of the vesicles using an α helical (AH) peptide, derived from hepatitis C virus NS5A protein, to assist the fusion process. A cell-free expression system producing the E. coli integral membrane protein Aquaporin Z (AqpZ) is directly incubated onto the tBLMs for expression and insertion of the IMP at the upper side of tBLMs. The incorporation of AqpZ into bilayers is monitored by QCM-D and compared to a control experiment (without plasmid in the cell-free expression system). We demonstrate that an IMP such as AqpZ, produced by a cell-free expression system without any protein purification, can be incorporated into an engineered tBLM preassembled at the surface of a gold-coated sensor.
- 11 March 2014
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (11) , 3132-3141
Preparation of Tethered-Lipid Bilayers on Gold Surfaces for the Incorporation of Integral Membrane Proteins Synthesized by Cell-Free Expression
There is an increasing interest to express and study membrane proteins in vitro. New techniques to produce and insert functional membrane proteins into planar lipid bilayers have to be developed. In this work, we produce a tethered lipid bilayer membrane (tBLM) to provide sufficient space for the incorporation of the integral membrane protein (IMP) Aquaporin Z (AqpZ) between the tBLM and the surface of the sensor. We use a gold (Au)-coated sensor surface compatible with mechanical sensing using a quartz crystal microbalance with dissipation monitoring (QCM-D) or optical sensing using the surface plasmon resonance (SPR) method. tBLM is produced by vesicle fusion onto a thin gold film, using phospholipid-polyethylene glycol (PEG) as a spacer. Lipid vesicles are composed of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-poly(ethyleneglycol)-2000-N-[3-(2-pyridyldithio)propionate], so-called DSPE-PEG-PDP, at different molar ratios (respectively, 99.5/0.5, 97.5/2.5, and 95/5 mol %), and tBLM formation is characterized using QCM-D, SPR, and atomic force technology (AFM). We demonstrate that tBLM can be produced on the gold surface after rupture of the vesicles using an α helical (AH) peptide, derived from hepatitis C virus NS5A protein, to assist the fusion process. A cell-free expression system producing the E. coli integral membrane protein Aquaporin Z (AqpZ) is directly incubated onto the tBLMs for expression and insertion of the IMP at the upper side of tBLMs. The incorporation of AqpZ into bilayers is monitored by QCM-D and compared to a control experiment (without plasmid in the cell-free expression system). We demonstrate that an IMP such as AqpZ, produced by a cell-free expression system without any protein purification, can be incorporated into an engineered tBLM preassembled at the surface of a gold-coated sensor.
- 11 February 2007
- Published by Elsevier in Microelectronic Engineering
- Vol. 84 (5-8) , 1710-1713
Biofunctionalization of gold nanoparticles and their spectral properties
- 11 February 2007
- Published by Elsevier in Microelectronic Engineering
- Vol. 84 (5-8) , 1710-1713
Biofunctionalization of gold nanoparticles and their spectral properties