Frédéric Juget
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frédéric Juget has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Claude Bailat
Institute of Radiation Physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland
6 shared publications- Claude Bailat
Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland
5 shared publications Youcef Nedjadi
Institute of Radiation Physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland
5 shared publications- François Bochud
Institute of Radiation Physics Lausanne University Hospital Lausanne Vaud Switzerland
4 shared publications M. Teresa Durán
Institute of Radiation Physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland
4 shared publicationsThierry Buchillier
Institute of Radiation Physics, Lausanne, Switzerland
4 shared publications
Latest Publications
- 23 January 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 230, 112462
Determination of the gamma emission intensities of 61Cu
- 23 January 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 230, 112462
Determination of the gamma emission intensities of 61Cu
- Open Access
Measurement of the 171Tm beta spectrum
The beta spectrum of the main transition of the beta-decay of 171Tm was measured using a double focalizing spectrometer. The instrument was lately improved in order to reduce its low energy threshold to 34 keV. We used the spectrometer to measure the beta spectrum end-point energy of the main transition of 171Tm decay using the Kurie plot formalism. We report a new value of 97.60(38) keV, which is in agreement with previous measurements. In addition, the spectrum shape was compared with the xi-approximation calculation where the shape factor is equal to 1 and good agreement was found between the theory and the measurement at the 1% level.
Open AccessMeasurement of the 171Tm beta spectrum
The beta spectrum of the main transition of the beta-decay of 171Tm was measured using a double focalizing spectrometer. The instrument was lately improved in order to reduce its low energy threshold to 34 keV. We used the spectrometer to measure the beta spectrum end-point energy of the main transition of 171Tm decay using the Kurie plot formalism. We report a new value of 97.60(38) keV, which is in agreement with previous measurements. In addition, the spectrum shape was compared with the xi-approximation calculation where the shape factor is equal to 1 and good agreement was found between the theory and the measurement at the 1% level.
- 27 September 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 202, 111058
Measurement of the 171Tm beta spectrum
- 27 September 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 202, 111058
Measurement of the 171Tm beta spectrum
- 27 July 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 200, 110955
Corrigendum to “Determination of the gamma and X-ray emission intensities of terbium-161” [Appl. Radiat. Isot. 174 (2021) 109770]
- 27 July 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 200, 110955
Corrigendum to “Determination of the gamma and X-ray emission intensities of terbium-161” [Appl. Radiat. Isot. 174 (2021) 109770]
- Open Access
Activity Measurement of 44Sc and Calibration of Activity Measurement Instruments on Production Sites and Clinics
44Sc is a promising radionuclide for positron emission tomography (PET) in nuclear medicine. As a part of the implementation of a production site for 44Sc, precise knowledge of the activity of the product is necessary. At the Paul Scherrer Institute (PSI) and the University of Bern (UniBE), 44Sc is produced by enriched 44CaO-target irradiation with a cyclotron. The two sites use different techniques for activity measurement, namely a dose calibrator at the PSI and a gamma-ray spectrometry system at UniBE and PSI. In this work, the 44Sc was produced at the PSI, and samples of the product were prepared in dedicated containers for onsite measurements at PSI, UniBE, and the Institute of Radiation Physics (IRA) in Lausanne for precise activity measurement using primary techniques and for the calibration of the reference ionization chambers. An accuracy of 1% was obtained for the activity measurement, allowing for a precise calibration of the dose calibrator and gamma-ray spectrometry of the two production sites. Each production site now has the capability of measuring 44Sc activity with an accuracy of 2%.
Open AccessActivity Measurement of 44Sc and Calibration of Activity Measurement Instruments on Production Sites and Clinics
44Sc is a promising radionuclide for positron emission tomography (PET) in nuclear medicine. As a part of the implementation of a production site for 44Sc, precise knowledge of the activity of the product is necessary. At the Paul Scherrer Institute (PSI) and the University of Bern (UniBE), 44Sc is produced by enriched 44CaO-target irradiation with a cyclotron. The two sites use different techniques for activity measurement, namely a dose calibrator at the PSI and a gamma-ray spectrometry system at UniBE and PSI. In this work, the 44Sc was produced at the PSI, and samples of the product were prepared in dedicated containers for onsite measurements at PSI, UniBE, and the Institute of Radiation Physics (IRA) in Lausanne for precise activity measurement using primary techniques and for the calibration of the reference ionization chambers. An accuracy of 1% was obtained for the activity measurement, allowing for a precise calibration of the dose calibrator and gamma-ray spectrometry of the two production sites. Each production site now has the capability of measuring 44Sc activity with an accuracy of 2%.
- 1 January 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (1A)
Update of the BIPM comparison BIPM.RI(II)-K1.Lu-177 of activity measurements of the radionuclide 177Lu to include the 2013 result of the IFIN-HH (Romania), the 2014 result of the LNE-LNHB (France) and the 2022 result of the IRA (Switzerland)
Main text: Since 2000, 7 laboratories have submitted 7 samples of 177Lu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Lu-177. Recently, the IFIN-HH (Romania), the LNE-LNHB (France) and the IRA (Switzerland) participated in the comparison. The degrees of equivalence between each equivalent activity measured in the SIR or linked to the SIR from the CCRI(II)-K2.Lu-177 comparison have been calculated. The results are given in the form of a table and a graphical representation is also displayed. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (1A)
Update of the BIPM comparison BIPM.RI(II)-K1.Lu-177 of activity measurements of the radionuclide 177Lu to include the 2013 result of the IFIN-HH (Romania), the 2014 result of the LNE-LNHB (France) and the 2022 result of the IRA (Switzerland)
Main text: Since 2000, 7 laboratories have submitted 7 samples of 177Lu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Lu-177. Recently, the IFIN-HH (Romania), the LNE-LNHB (France) and the IRA (Switzerland) participated in the comparison. The degrees of equivalence between each equivalent activity measured in the SIR or linked to the SIR from the CCRI(II)-K2.Lu-177 comparison have been calculated. The results are given in the form of a table and a graphical representation is also displayed. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- Open Access
- 14 March 2022
- Published by Springer Nature in EJNMMI Physics
- Vol. 9 (1) , 1-18
Precise activity measurements of medical radionuclides using an ionization chamber: a case study with Terbium-161
Background: 161Tb draws an increasing interest in nuclear medicine for therapeutic applications. More than 99% of the emitted gamma and X-rays of 161Tb have an energy below 100 keV. Consequently, precise activity measurement of 161Tb becomes inaccurate with radionuclide dose calibrators when using inappropriate containers or calibration factors to account for the attenuation of this low energy radiation. To evaluate the ionization chamber response, the sample activity must be well known. This can be performed using standards traceable to the Système International de Référence, which is briefly described as well as the method to standardize the radionuclides. Methods: In this study, the response of an ionization chamber using different container types and volumes was assessed using 161Tb. The containers were filled with a standardized activity solution of 161Tb and measured with a dedicated ionization chamber, providing an accurate response. The results were compared with standardized solutions of high-energy gamma-emitting radionuclides such as 137Cs, 60Co, 133Ba and 57Co. Results: For the glass vial type with an irregular glass thickness, the 161Tb measurements gave a deviation of 4.5% between two vials of the same type. The other glass vial types have a much more regular thickness and no discrepancy was observed in the response of the ionization chamber for these type of vials. Measurements with a plastic Eppendorf tube showed stable response, with greater sensitivity than the glass vials. Conclusion: Ionization chamber measurements for low-energy gamma emitters (< 100 keV), show deviation depending on the container type used. Therefore, a careful selection of the container type must be done for activity assessment of 161Tb using radionuclide dose calibrators. In conclusion, it was highlighted that appropriate calibration factors must be used for each container geometry when measuring 161Tb and, more generally, for low-energy gamma emitters.
- 14 March 2022
- Published by Springer Nature in EJNMMI Physics
- Vol. 9 (1) , 1-18
Open AccessPrecise activity measurements of medical radionuclides using an ionization chamber: a case study with Terbium-161
Background: 161Tb draws an increasing interest in nuclear medicine for therapeutic applications. More than 99% of the emitted gamma and X-rays of 161Tb have an energy below 100 keV. Consequently, precise activity measurement of 161Tb becomes inaccurate with radionuclide dose calibrators when using inappropriate containers or calibration factors to account for the attenuation of this low energy radiation. To evaluate the ionization chamber response, the sample activity must be well known. This can be performed using standards traceable to the Système International de Référence, which is briefly described as well as the method to standardize the radionuclides. Methods: In this study, the response of an ionization chamber using different container types and volumes was assessed using 161Tb. The containers were filled with a standardized activity solution of 161Tb and measured with a dedicated ionization chamber, providing an accurate response. The results were compared with standardized solutions of high-energy gamma-emitting radionuclides such as 137Cs, 60Co, 133Ba and 57Co. Results: For the glass vial type with an irregular glass thickness, the 161Tb measurements gave a deviation of 4.5% between two vials of the same type. The other glass vial types have a much more regular thickness and no discrepancy was observed in the response of the ionization chamber for these type of vials. Measurements with a plastic Eppendorf tube showed stable response, with greater sensitivity than the glass vials. Conclusion: Ionization chamber measurements for low-energy gamma emitters (< 100 keV), show deviation depending on the container type used. Therefore, a careful selection of the container type must be done for activity assessment of 161Tb using radionuclide dose calibrators. In conclusion, it was highlighted that appropriate calibration factors must be used for each container geometry when measuring 161Tb and, more generally, for low-energy gamma emitters.
- Open Access
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109770
Determination of the gamma and X-ray emission intensities of terbium-161
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109770
Open AccessDetermination of the gamma and X-ray emission intensities of terbium-161
- 1 April 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 134, 95-99
A portable precision ionization chamber: The transfer ionization reference chamber
- 1 April 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 134, 95-99
A portable precision ionization chamber: The transfer ionization reference chamber
- 1 December 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 118, 215-220
Determination of 137Cs half-life with an ionization chamber
- 1 December 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 118, 215-220
Determination of 137Cs half-life with an ionization chamber