Ganesh Krishnamurthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ganesh Krishnamurthy has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Anne Marie Cahill
Children’s Hospital of Philadelphia, University of Pennsylvania, Philadelphia, Pennsylvania, United States
3 shared publicationsAbhay Srinivasan
Children’s Hospital of Philadelphia, University of Pennsylvania, Philadelphia, Pennsylvania, United States
2 shared publicationsFernando Escobar
Children’s Hospital of Philadelphia, University of Pennsylvania, Philadelphia, Pennsylvania, United States
2 shared publicationsMarc S. Keller
Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Boulevard, Philadelphia, PA 19104
2 shared publications- Melkamu Adeb
Department of Radiology, Yale New Haven Health, Bridgeport Hospital, Bridgeport, Connecticut
2 shared publications Adeka McIntosh
Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Boulevard, Philadelphia, PA 19104
1 shared publication
Latest Publications
- 1 November 2020
- Published by Elsevier in Paediatric Respiratory Reviews
- Vol. 36, 2-7
Pediatric pulmonary lymphatic flow Disorders: Diagnosis and management
- 1 November 2020
- Published by Elsevier in Paediatric Respiratory Reviews
- Vol. 36, 2-7
Pediatric pulmonary lymphatic flow Disorders: Diagnosis and management
- Open Access
- 1 February 2020
- Published by Georg Thieme Verlag KG
- Vol. 04 (03) , P526
Fibrin Sheath Removal from Port-A-Cath by Exteriorization of the Catheter by Snaring Through a Shortened Vascular Sheath: A Novel Technique
Objectives: Port-a-caths are commonly placed central venous access devices in children. Fibrin sheath formation is a common complication, leading to port malfunction. Unlike other tunneled central line, port-a-caths cannot easily be exchanged over a wire. Treatment of fibrin sheath formation includes fibrinolytic therapy, fibrin sheath stripping via transfemoral route or replacement. We describe an alternative minimally invasive technique of fibrin sheath removal. Methods: This novel technique was performed on four patients with port-a-cath who had failed fibrinolytic therapy and presence of fibrin sheath confirmed on contrast injection. The port was accessed under aseptic precautions. Ultrasound-guided right internal jugular vein access was performed just cranial to previous catheter insertion site, and shortened vascular sheath, which was one and half times larger French size relative to the size of the port catheter, was inserted. Catheter tip was successfully snared under fluoroscopic guidance using a 30 mm Goose Neck snare. Catheter was then exteriorized through the sheath. Catheter was then cleaned with a wet Telfa gauze to clear any fibrin sheath. A 0.018” Nitrex wire was also passed through the catheter to clear intracatheter clot or debris. Catheter was reinserted back through the vascular sheath into right atrium with the help of snare. Results: Port-a-cath function was restored in all four patients with satisfactory flushing and aspiration. Contrast venogram was performed to confirm function and no residual fibrin sheath was demonstrated. No complications were encountered. Conclusion: Fibrin sheath removal by exteriorization of port catheter by snaring through shortened vascular sheath is an attractive alternative which is minimally invasive and highly effective, compared to traditional stripping or replacement with new port. Publication Date: 26 April 2021 (online) © 2020. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 February 2020
- Published by Georg Thieme Verlag KG
- Vol. 04 (03) , P526
Open AccessFibrin Sheath Removal from Port-A-Cath by Exteriorization of the Catheter by Snaring Through a Shortened Vascular Sheath: A Novel Technique
Objectives: Port-a-caths are commonly placed central venous access devices in children. Fibrin sheath formation is a common complication, leading to port malfunction. Unlike other tunneled central line, port-a-caths cannot easily be exchanged over a wire. Treatment of fibrin sheath formation includes fibrinolytic therapy, fibrin sheath stripping via transfemoral route or replacement. We describe an alternative minimally invasive technique of fibrin sheath removal. Methods: This novel technique was performed on four patients with port-a-cath who had failed fibrinolytic therapy and presence of fibrin sheath confirmed on contrast injection. The port was accessed under aseptic precautions. Ultrasound-guided right internal jugular vein access was performed just cranial to previous catheter insertion site, and shortened vascular sheath, which was one and half times larger French size relative to the size of the port catheter, was inserted. Catheter tip was successfully snared under fluoroscopic guidance using a 30 mm Goose Neck snare. Catheter was then exteriorized through the sheath. Catheter was then cleaned with a wet Telfa gauze to clear any fibrin sheath. A 0.018” Nitrex wire was also passed through the catheter to clear intracatheter clot or debris. Catheter was reinserted back through the vascular sheath into right atrium with the help of snare. Results: Port-a-cath function was restored in all four patients with satisfactory flushing and aspiration. Contrast venogram was performed to confirm function and no residual fibrin sheath was demonstrated. No complications were encountered. Conclusion: Fibrin sheath removal by exteriorization of port catheter by snaring through shortened vascular sheath is an attractive alternative which is minimally invasive and highly effective, compared to traditional stripping or replacement with new port. Publication Date: 26 April 2021 (online) © 2020. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- Open Access
- 1 February 2020
- Published by Georg Thieme Verlag KG
- Vol. 04 (03) , P410
Extraction of Stuck Bone Biopsy Fragment within the Cannula Using Heat from Cautery Device
Educational Poster Background: Image-guided bone biopsy is a commonly performed intervention. Most bone biopsy instruments contain a guiding trocar and an inner biopsy cannula. Sample core getting stuck within the biopsy cannula is a known complication, and it may be impossible to extrude the fragment, rendering the procedure futile. Furthermore, in children, target may be small and repeat biopsy may be difficult. Therefore, extruding the stuck fragment becomes essential. The risk of tight lodging of the core increases when the core length is longer than 1 cm and when target bone is sclerotic. Some authors have described a “biopsy-the-biopsy” technique, but this technique fragments the sample and works only for large biopsy cannula. We describe a technique to extrude the stuck fragment utilizing a battery-operated disposable cautery device wherein the heated tip is brought in contact with the distal end of the biopsy cannula. The heat causes expansion of the metallic biopsy cannula and thus facilitates easy extrusion of the bony fragment. We have used this technique in five cases and have successfully recovered the biopsied fragment in all. In two cases, we noted slight charring of the margins, but this did not impede the diagnosis by pathology. We have not determined whether this technique affects culture yield. In conclusion, a stuck core can be easily recovered using a cautery device to cause metallic cannula expansion. This easy remedy can obviate the need for additional sampling or salvage a futile procedure; this technique may not impede the pathological diagnosis. Stuck bone biopsy core within the cannula can be removed by applying heat to the cannula, which causes metal expansion and thus facilitates extrusion of the fragment. This technique is simple and can prevent additional sampling or additional new device usage. Publication Date: 26 April 2021 (online) © 2020. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 February 2020
- Published by Georg Thieme Verlag KG
- Vol. 04 (03) , P410
Open AccessExtraction of Stuck Bone Biopsy Fragment within the Cannula Using Heat from Cautery Device
Educational Poster Background: Image-guided bone biopsy is a commonly performed intervention. Most bone biopsy instruments contain a guiding trocar and an inner biopsy cannula. Sample core getting stuck within the biopsy cannula is a known complication, and it may be impossible to extrude the fragment, rendering the procedure futile. Furthermore, in children, target may be small and repeat biopsy may be difficult. Therefore, extruding the stuck fragment becomes essential. The risk of tight lodging of the core increases when the core length is longer than 1 cm and when target bone is sclerotic. Some authors have described a “biopsy-the-biopsy” technique, but this technique fragments the sample and works only for large biopsy cannula. We describe a technique to extrude the stuck fragment utilizing a battery-operated disposable cautery device wherein the heated tip is brought in contact with the distal end of the biopsy cannula. The heat causes expansion of the metallic biopsy cannula and thus facilitates easy extrusion of the bony fragment. We have used this technique in five cases and have successfully recovered the biopsied fragment in all. In two cases, we noted slight charring of the margins, but this did not impede the diagnosis by pathology. We have not determined whether this technique affects culture yield. In conclusion, a stuck core can be easily recovered using a cautery device to cause metallic cannula expansion. This easy remedy can obviate the need for additional sampling or salvage a futile procedure; this technique may not impede the pathological diagnosis. Stuck bone biopsy core within the cannula can be removed by applying heat to the cannula, which causes metal expansion and thus facilitates extrusion of the fragment. This technique is simple and can prevent additional sampling or additional new device usage. Publication Date: 26 April 2021 (online) © 2020. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 November 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (11) , 1660-1668
Lower Extremity Vascular Access in Neonates and Infants: A Single Institutional Experience
- 1 November 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (11) , 1660-1668
Lower Extremity Vascular Access in Neonates and Infants: A Single Institutional Experience
- 15 March 2014
- Published by Springer Nature
- p. 251-261
Vascular Interventions: Lymphangiography and Thoracic Duct Embolization
- 15 March 2014
- Published by Springer Nature
- p. 251-261
Vascular Interventions: Lymphangiography and Thoracic Duct Embolization
- 1 May 2012
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 23 (5) , 604-612
Radiologically Placed Tunneled Hemodialysis Catheters: A Single Pediatric Institutional Experience of 120 Patients
- 1 May 2012
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 23 (5) , 604-612
Radiologically Placed Tunneled Hemodialysis Catheters: A Single Pediatric Institutional Experience of 120 Patients
- 26 May 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (1) , 14-24
Vascular Access in Children
Establishment of stable vascular access is one of the essential and most challenging procedures in a pediatric hospital. Many clinical specialties provide vascular service in a pediatric hospital. At the top of the “expert procedural pyramid” is the pediatric interventional radiologist, who is best suited and trained to deliver this service. Growing awareness regarding the safety and high success rate of vascular access using image guidance has led to increased demand from clinicians to provide around-the-clock vascular access service by pediatric interventional radiologists. Hence, the success of a vascular access program, with the pediatric interventional radiologist as the key provider, is challenging, and a coordinated multidisciplinary team effort is essential for success. However, there are few dedicated pediatric interventional radiologists across the globe, and also only a couple of training programs exist for pediatric interventions. This article gives an overview of the technical aspects of pediatric vascular access and provides useful tips for obtaining vascular access in children safely and successfully using image guidance.
- 26 May 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (1) , 14-24
Vascular Access in Children
Establishment of stable vascular access is one of the essential and most challenging procedures in a pediatric hospital. Many clinical specialties provide vascular service in a pediatric hospital. At the top of the “expert procedural pyramid” is the pediatric interventional radiologist, who is best suited and trained to deliver this service. Growing awareness regarding the safety and high success rate of vascular access using image guidance has led to increased demand from clinicians to provide around-the-clock vascular access service by pediatric interventional radiologists. Hence, the success of a vascular access program, with the pediatric interventional radiologist as the key provider, is challenging, and a coordinated multidisciplinary team effort is essential for success. However, there are few dedicated pediatric interventional radiologists across the globe, and also only a couple of training programs exist for pediatric interventions. This article gives an overview of the technical aspects of pediatric vascular access and provides useful tips for obtaining vascular access in children safely and successfully using image guidance.