Laurence Schacher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Laurence Schacher has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Dominique Adolphe
Laboratoire de Physique et Mécanique Textiles LPMT, Université de Haute Alsace (UHA), 68093 Mulhouse, France
3 shared publications - Nabyl Khenoussi
Laboratoire de Physique et Mécanique Textiles EA 4365
2 shared publications A. Dieterlen
Laboratory of Modelling, Intelligence, Process and Systems, MIPS – EA 2332 – UHA - University of Haute-Alsace, 4 rue des frères lumière, 68093 Mulhouse, France
1 shared publicationA. Moukadem
Laboratory of Modelling, Intelligence, Process and Systems, MIPS – EA 2332 – UHA - University of Haute-Alsace, 4 rue des frères lumière, 68093 Mulhouse, France
1 shared publicationBénédicte Lebeau
1 shared publicationD. Adolphe
Laboratory of Textile Physics and Mechanics, LPMT - EA 4365 - UHA, University of Haute-Alsace, 11, rue Alfred WERNER, 68093 Mulhouse CEDEX, France
1 shared publication
Latest Publications
- Open Access
- 1 October 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 254 (7) , 072008
Smart wheelchair: integration of multiple sensors
The aim of the present work is to develop a smart wheelchair by integrating multiple sensors for measuring user's physiological signals and subsequently transmitting and monitoring the treated signals to the user, a designated person or institution. Among other sensors, force, accelerometer, and temperature sensors are successfully integrated within both the backrest and the seat cushions of the wheelchair; while a pulse sensor is integrated within the armrest. The pulse sensor is connected to an amplification circuit board that is, in turn, placed within the armrest. The force and temperature sensors are integrated into a textile cover of the cushions by means of embroidery and sewing techniques. The signal from accelerometer is transmitted through Wi-Fi connection. The electrical connections needed for power supplying of sensors are made by embroidered conductive threads.
- 1 October 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 254 (7) , 072008
Open AccessSmart wheelchair: integration of multiple sensors
The aim of the present work is to develop a smart wheelchair by integrating multiple sensors for measuring user's physiological signals and subsequently transmitting and monitoring the treated signals to the user, a designated person or institution. Among other sensors, force, accelerometer, and temperature sensors are successfully integrated within both the backrest and the seat cushions of the wheelchair; while a pulse sensor is integrated within the armrest. The pulse sensor is connected to an amplification circuit board that is, in turn, placed within the armrest. The force and temperature sensors are integrated into a textile cover of the cushions by means of embroidery and sewing techniques. The signal from accelerometer is transmitted through Wi-Fi connection. The electrical connections needed for power supplying of sensors are made by embroidered conductive threads.
- Open Access
- 1 March 2017
- Published by Walter de Gruyter GmbH in Autex Research Journal
- Vol. 17 (1) , 12-19
Frictional Sound Analysis by Simulating the Human Arm Movement
Fabric noise generated by fabric-to-fabric friction is considered as one of the auditory disturbances that can have an impact on the quality of some textile products. For this reason, an instrument has been developed to analyse this phenomenon. The instrument is designed to simulate the relative movement of a human arm when walking. In order to understand the nature of the relative motion of a human arm, films of the upper half of the human body were taken. These films help to define the parameters required for movement simulation. These parameters are movement trajectory, movement velocity, arm pressure applied on the lateral part of the trunk and the friction area. After creating the instrument, a set of soundtracks related to the noise generated by fabric-to-fabric friction was recorded. The recordings were treated with a specific software to extract the sound parameters and the acoustic imprints of fabric were obtained.
- 1 March 2017
- Published by Walter de Gruyter GmbH in Autex Research Journal
- Vol. 17 (1) , 12-19
Open AccessFrictional Sound Analysis by Simulating the Human Arm Movement
Fabric noise generated by fabric-to-fabric friction is considered as one of the auditory disturbances that can have an impact on the quality of some textile products. For this reason, an instrument has been developed to analyse this phenomenon. The instrument is designed to simulate the relative movement of a human arm when walking. In order to understand the nature of the relative motion of a human arm, films of the upper half of the human body were taken. These films help to define the parameters required for movement simulation. These parameters are movement trajectory, movement velocity, arm pressure applied on the lateral part of the trunk and the friction area. After creating the instrument, a set of soundtracks related to the noise generated by fabric-to-fabric friction was recorded. The recordings were treated with a specific software to extract the sound parameters and the acoustic imprints of fabric were obtained.
- Open Access
- 1 December 2015
- Published by Walter de Gruyter GmbH in Autex Research Journal
- Vol. 15 (4) , 280-287
Development of Personal Protection Equipment for Medical Staff: Case of Dental Surgeon
During daily oral health care, dental surgeons are in contact with numerous potentially infectious germs from patients’ saliva and blood. Appropriate personal protection equipment should be chosen to mitigate these risks, but the garment must also be comfortable and not hamper activities. This paper presents our research work on optimised working clothing for dentists and discusses some important points in the functional design. Following a consumer study on how users wear the garment and what are their expectations, three main functions were investigated: protection, ergonomics and thermal comfort. Aesthetic appearance was also taken into consideration as it is necessary that the wearer should feel appropriately and attractively dressed in the context of health care. Concerning protection, spray tests in real conditions helped us to localise the potential contamination areas on the garment and led us to select a three-layered material that is protective and breathable enough. However, this part of the garments made from these fabrics exhibited low thermal comfort and the wearer felt some discomfort. In terms of ergonomics, instrumented garments were worn and pressure measurements were taken. The results highlight that a special shape and raglan sleeves should be selected for a better dynamic comfort. Concerning thermal comfort, an infrared camera was used to detect warm zones of the garment where heat and moisture transfers should be enhanced. Breathable, stretchable and shape-retaining knitted fabric that is usually used for sportswear was selected. These fabrics were strategically placed as low and high vents to promote a chimney effect, which minimises retention of heat and humidity inside the garment. The usual PES/cotton fabric was selected for the rest of the gown. Based on these results, a new gown has been proposed. Through fitting tests conducted in a hospital on 25 dentists, it was revealed that the new design was highly appreciated, particularly on the ergonomic structure of the sleeves and thermal comfort of breathable zones. However, some points can be further improved, such as durability of the PES/cotton fabric, the neck length or the shape of ‘breathable zones’. The final product will be produced based on necessary improvements
- 1 December 2015
- Published by Walter de Gruyter GmbH in Autex Research Journal
- Vol. 15 (4) , 280-287
Open AccessDevelopment of Personal Protection Equipment for Medical Staff: Case of Dental Surgeon
During daily oral health care, dental surgeons are in contact with numerous potentially infectious germs from patients’ saliva and blood. Appropriate personal protection equipment should be chosen to mitigate these risks, but the garment must also be comfortable and not hamper activities. This paper presents our research work on optimised working clothing for dentists and discusses some important points in the functional design. Following a consumer study on how users wear the garment and what are their expectations, three main functions were investigated: protection, ergonomics and thermal comfort. Aesthetic appearance was also taken into consideration as it is necessary that the wearer should feel appropriately and attractively dressed in the context of health care. Concerning protection, spray tests in real conditions helped us to localise the potential contamination areas on the garment and led us to select a three-layered material that is protective and breathable enough. However, this part of the garments made from these fabrics exhibited low thermal comfort and the wearer felt some discomfort. In terms of ergonomics, instrumented garments were worn and pressure measurements were taken. The results highlight that a special shape and raglan sleeves should be selected for a better dynamic comfort. Concerning thermal comfort, an infrared camera was used to detect warm zones of the garment where heat and moisture transfers should be enhanced. Breathable, stretchable and shape-retaining knitted fabric that is usually used for sportswear was selected. These fabrics were strategically placed as low and high vents to promote a chimney effect, which minimises retention of heat and humidity inside the garment. The usual PES/cotton fabric was selected for the rest of the gown. Based on these results, a new gown has been proposed. Through fitting tests conducted in a hospital on 25 dentists, it was revealed that the new design was highly appreciated, particularly on the ergonomic structure of the sleeves and thermal comfort of breathable zones. However, some points can be further improved, such as durability of the PES/cotton fabric, the neck length or the shape of ‘breathable zones’. The final product will be produced based on necessary improvements
- 1 May 2014
- Published by Elsevier in European Polymer Journal
- Vol. 54, 71-78
Electrospinning of PAN nanofibers incorporating SBA-15-type ordered mesoporous silica particles
- 1 May 2014
- Published by Elsevier in European Polymer Journal
- Vol. 54, 71-78
Electrospinning of PAN nanofibers incorporating SBA-15-type ordered mesoporous silica particles
- 23 March 2011
- Published by Springer Nature in Experimental Techniques
- Vol. 36 (2) , 32-39
Nanofiber Production: Study and Development of Electrospinning Device
- 23 March 2011
- Published by Springer Nature in Experimental Techniques
- Vol. 36 (2) , 32-39
Nanofiber Production: Study and Development of Electrospinning Device