Daniel Augusto de Faria Almeida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniel Augusto de Faria Almeida has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Piza Pellizzer
Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, Araçatuba, Sao Paulo, Brazil
5 shared publications - Victor Eduardo de Souza Batista
Department of Prosthodontics Presidente Prudente Dental School University of Western São Paulo ‐ UNOESTE Presidente Prudente Brazil
5 shared publications - Fellippo Ramos Verri
Department of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University Júlio de Mesquita Filho‐UNESP Araçatuba Brazil
4 shared publications - Cleidiel Aparecido Araujo Lemos
Department of Dentistry, Federal University of Juiz de Fora (UFJF), Campus Avançado Governador Valadares, Governador Valadares 35010-180, MG, Brazil
3 shared publications - Caroline Cantieri de Mello
Araçatuba Dental School, UNESP - Univ Estadual Paulista, Campus of Araçatuba, Department of Dental Materials and Prosthodontics, Araçatuba, São Paulo, Brazil
2 shared publications - Joel Ferreira Santiago Junior
University of Sacred Heart - USC, Department of Health Sciences, São Paulo, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 February 2018
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 29 (1) , 30-35
Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis
The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.
- 1 February 2018
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 29 (1) , 30-35
Open AccessRetention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis
The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.
- 13 October 2017
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 41 (8) , 644-651
Three-dimensional finite element analysis of glass fiber and cast metal posts with different alloys for reconstruction of teeth without ferrule
The aim of this study was to evaluate different materials for restoration of teeth without ferrule by three-dimensional (3D) finite element analysis (FEA). Five models simulating the maxillary central incisor and surrounding bone were simulated according to the type of post: glass fibre post (GFP) or cast metal post (CMP) with different alloys such as gold (Au), silver–palladium (AgPd), copper–aluminum (CuAl) and nickel–chromium (NiCr). Models were designed using Invesalius and Rhinoceros. FEAs were made using FEMAP and NeiNastran, with an applied axial force of 100 N and oblique occlusal load at 45°. Stress distribution among groups was analysed by two-way analysis of variance (ANOVA), followed by post-hoc Tukey’s test. The GFP showed the best stress distribution in the post, followed by CMP with Au, AgPd, CuAl and NiCr alloys, respectively (p < .001). No statistically significant difference in the stress distribution in teeth was found under application of axial load (p > .05). Under oblique load, the GFP generated the highest values of tension among the models, followed by the CMP with NiCr alloy than other models (p < .001). The use of GFP resulted in a lower stress concentration in the post, but increased stress in the tooth without ferrule. The CMP with NiCr alloy exhibited the highest stress distribution among other CMP. To avoid higher stress in teeth, alloys of Au, AgPd and CuAl, respectively, are recommended.
- 13 October 2017
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 41 (8) , 644-651
Three-dimensional finite element analysis of glass fiber and cast metal posts with different alloys for reconstruction of teeth without ferrule
The aim of this study was to evaluate different materials for restoration of teeth without ferrule by three-dimensional (3D) finite element analysis (FEA). Five models simulating the maxillary central incisor and surrounding bone were simulated according to the type of post: glass fibre post (GFP) or cast metal post (CMP) with different alloys such as gold (Au), silver–palladium (AgPd), copper–aluminum (CuAl) and nickel–chromium (NiCr). Models were designed using Invesalius and Rhinoceros. FEAs were made using FEMAP and NeiNastran, with an applied axial force of 100 N and oblique occlusal load at 45°. Stress distribution among groups was analysed by two-way analysis of variance (ANOVA), followed by post-hoc Tukey’s test. The GFP showed the best stress distribution in the post, followed by CMP with Au, AgPd, CuAl and NiCr alloys, respectively (p < .001). No statistically significant difference in the stress distribution in teeth was found under application of axial load (p > .05). Under oblique load, the GFP generated the highest values of tension among the models, followed by the CMP with NiCr alloy than other models (p < .001). The use of GFP resulted in a lower stress concentration in the post, but increased stress in the tooth without ferrule. The CMP with NiCr alloy exhibited the highest stress distribution among other CMP. To avoid higher stress in teeth, alloys of Au, AgPd and CuAl, respectively, are recommended.
- 1 June 2017
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 28 (4) , e381-e383
Removable Partial Denture After Gunshot Injury
The aim of this study was to report a patient of rehabilitation with removable partial denture retained by implants in-patient who suffered injury after firearm shooting. A 19-year-old man presented to the hospital of the Val Paraíso city after being hit by a bullet in the right on the face, affecting the teeth 12 to 16. The surgery to remove the shards of teeth, and bullet was performed. Surgical team opted for installation of implants without bone grafts; however, due to extensive loss of alveolar bone, only 3 tilted implants (2 Ø3.75 × 8.5 mm and 1 Ø3.75 × 10 mm) were installed. After recovery, the patient was referred to the Araçatuba Dental School-UNESP for the rehabilitation on the affected region. The difficulty of rehabilitation with conventional fixed prostheses was verified during the prosthetic phase. This way, it was opted for rehabilitation with removable partial dentures associated with dental implant. Two attachment system ERA (ERA, Sterngold) were positioned in the bar to make the removable partial denture. After 5 years of follow-up, the authors can conclude that the use of removable partial denture retained by implants is effective for functional and aesthetic rehabilitation, favoring socialization and self-esteem of the patient.
- 1 June 2017
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 28 (4) , e381-e383
Removable Partial Denture After Gunshot Injury
The aim of this study was to report a patient of rehabilitation with removable partial denture retained by implants in-patient who suffered injury after firearm shooting. A 19-year-old man presented to the hospital of the Val Paraíso city after being hit by a bullet in the right on the face, affecting the teeth 12 to 16. The surgery to remove the shards of teeth, and bullet was performed. Surgical team opted for installation of implants without bone grafts; however, due to extensive loss of alveolar bone, only 3 tilted implants (2 Ø3.75 × 8.5 mm and 1 Ø3.75 × 10 mm) were installed. After recovery, the patient was referred to the Araçatuba Dental School-UNESP for the rehabilitation on the affected region. The difficulty of rehabilitation with conventional fixed prostheses was verified during the prosthetic phase. This way, it was opted for rehabilitation with removable partial dentures associated with dental implant. Two attachment system ERA (ERA, Sterngold) were positioned in the bar to make the removable partial denture. After 5 years of follow-up, the authors can conclude that the use of removable partial denture retained by implants is effective for functional and aesthetic rehabilitation, favoring socialization and self-esteem of the patient.
- 1 October 2015
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 55, 187-192
Analysis of the biomechanical behavior of short implants: The photo-elasticity method
- 1 October 2015
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 55, 187-192
Analysis of the biomechanical behavior of short implants: The photo-elasticity method
- 13 April 2014
- Published by Springer Nature in Applied Physics B
- Vol. 117 (1) , 235-244
Photoelastic stress analysis of splinted and unitary implant-supported prostheses
- 13 April 2014
- Published by Springer Nature in Applied Physics B
- Vol. 117 (1) , 235-244
Photoelastic stress analysis of splinted and unitary implant-supported prostheses