Jianping Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jianping Cheng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Hao Ma
Tsinghua University
2 shared publications Zhi Zeng
2 shared publications- Zhi Zeng
Department of Engineering Physics, Tsinghua University, Beijing, China
2 shared publications - Daowei Dou
Department of Engineering Physics, Tsinghua University, Beijing 100084, China
1 shared publication - Feng Lin
Third Institute of Oceanography, Ministry of Natural Resources, Xiamen, China
1 shared publication H. Ma
Department of Engineering Physics Key Laboratory of Particle and Radiation Imaging (Ministry of Education) Tsinghua University 100084 Beijing China
1 shared publication
Latest Publications
- Open Access
Measurement of cosmic-ray muon flux at CJPL-II
In China Jinping Underground Laboratory (CJPL), the deepest and largest underground laboratory globally, the cosmic-ray muon flux is significantly reduced due to the substantial shielding provided by the overlying mountain. From 2016 to 2020, we measured the muon flux in the second phase of CJPL (CJPL-II) with a plastic scintillator muon telescope system, detecting 161 muon events over an effective live time of 1098 days. The detection efficiency was obtained by simulating the underground muon energy and angular distributions and the telescope system's response to underground muons. The cosmic-ray muon flux is determined to be (3.03 $\pm$ 0.24 (stat) $\pm$ 0.18 (sys)) $\times$ 10$^{-10}$ cm$^{-2}$s$^{-1}$, which is the lowest among underground laboratories worldwide.Open AccessMeasurement of cosmic-ray muon flux at CJPL-II
In China Jinping Underground Laboratory (CJPL), the deepest and largest underground laboratory globally, the cosmic-ray muon flux is significantly reduced due to the substantial shielding provided by the overlying mountain. From 2016 to 2020, we measured the muon flux in the second phase of CJPL (CJPL-II) with a plastic scintillator muon telescope system, detecting 161 muon events over an effective live time of 1098 days. The detection efficiency was obtained by simulating the underground muon energy and angular distributions and the telescope system's response to underground muons. The cosmic-ray muon flux is determined to be (3.03 $\pm$ 0.24 (stat) $\pm$ 0.18 (sys)) $\times$ 10$^{-10}$ cm$^{-2}$s$^{-1}$, which is the lowest among underground laboratories worldwide. - Open Access
- 1 October 2025
- Published by China Science Publishing & Media Ltd. in Nuclear Techniques
- Vol. 48 (10) , 100501
Calculation of nuclide activity conversion factor for in-situ γ measurement
Background In-situ γ measurements employ radiation detectors to quantify the environmental γ spectrum, and it is necessary to calculate the conversion factor that translates the characteristic peak count rate of the measured spectrum into the specific activity of radionuclides in surrounding materials. The calculation of the conversion factor essentially involves integrating the detection efficiency of gamma rays emitted from different spatial positions within the surrounding materials. However, numerical solutions for the integral are challenging in complex geometries, limiting the method's application.PurposeThis study aims to overcome the limitation of the integral method, simplify the calculation and broaden the scope of applications.MethodsThe Monte Carlo simulation technique was applied to calculating the integral of in-situ γ measurement. Firstly, the geometry of the surrounding materials was built in Geant4, and the emitted Geantinos facing the detector from the surroundings were sampled. Then, the positions whilst the Geantinos passed through the boundaries were logged. Subsequently, the parameters for the integral, such as the track lengths, were calculated and the conversion factor was obtained by calculating the average of the integral items of all particles. Finally, this method was applied to the conversion factor calculation for the building materials of the large polyethylene shielding chamber in the second phase of the China Jinping Underground Laboratory (CJPL).ResultsThe conversion factors for the 1 m thick polyethylene walls and an external 20 cm thick concrete support in CJPL are determined by abovementioned method and the computing efficiency is increased by more than 5 times, which allow us to assess the shielding capability of the polyethylene chamber against various nuclide backgrounds in the external concrete, providing support and reference for in-situ measurements in the second phase of CJPL.ConclusionsA novel method in this study to calculate the conversion factor for in-situ γ measurement overcomes the challenges of complex geometric integrations through random sampling and improves Monte Carlo simulation efficiency by transporting virtual particles, offering versatility in geometry and computational efficiency.
- 1 October 2025
- Published by China Science Publishing & Media Ltd. in Nuclear Techniques
- Vol. 48 (10) , 100501
Open AccessCalculation of nuclide activity conversion factor for in-situ γ measurement
Background In-situ γ measurements employ radiation detectors to quantify the environmental γ spectrum, and it is necessary to calculate the conversion factor that translates the characteristic peak count rate of the measured spectrum into the specific activity of radionuclides in surrounding materials. The calculation of the conversion factor essentially involves integrating the detection efficiency of gamma rays emitted from different spatial positions within the surrounding materials. However, numerical solutions for the integral are challenging in complex geometries, limiting the method's application.PurposeThis study aims to overcome the limitation of the integral method, simplify the calculation and broaden the scope of applications.MethodsThe Monte Carlo simulation technique was applied to calculating the integral of in-situ γ measurement. Firstly, the geometry of the surrounding materials was built in Geant4, and the emitted Geantinos facing the detector from the surroundings were sampled. Then, the positions whilst the Geantinos passed through the boundaries were logged. Subsequently, the parameters for the integral, such as the track lengths, were calculated and the conversion factor was obtained by calculating the average of the integral items of all particles. Finally, this method was applied to the conversion factor calculation for the building materials of the large polyethylene shielding chamber in the second phase of the China Jinping Underground Laboratory (CJPL).ResultsThe conversion factors for the 1 m thick polyethylene walls and an external 20 cm thick concrete support in CJPL are determined by abovementioned method and the computing efficiency is increased by more than 5 times, which allow us to assess the shielding capability of the polyethylene chamber against various nuclide backgrounds in the external concrete, providing support and reference for in-situ measurements in the second phase of CJPL.ConclusionsA novel method in this study to calculate the conversion factor for in-situ γ measurement overcomes the challenges of complex geometric integrations through random sampling and improves Monte Carlo simulation efficiency by transporting virtual particles, offering versatility in geometry and computational efficiency.
- Open Access
- 30 June 2021
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 9 (7) , 721
In-Situ Seawater Gamma Spectrometry with LaBr3 Detector at a Nuclear Power Plant Outlet
In a nuclear emergency, the application of in situ spectrometers for monitoring environmental radioactivity is significantly important, as information on the type and activity of radionuclides released from the accident can be obtained quickly. However, in emergency environmental radiological monitoring, a balance between energy resolution and detecting efficiency must be considered in selecting an appropriate detector. In this study, in situ gamma spectrometry was conducted with the LaBr3 detector to determine the radioactivity of seawater at the discharging outlet of a coastal nuclear power plant in southeast China. The results show that the LaBr3 scintillator has excellent energy resolution and detection efficiency, making it a promising detector for emergency monitoring.
- 30 June 2021
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 9 (7) , 721
Open AccessIn-Situ Seawater Gamma Spectrometry with LaBr3 Detector at a Nuclear Power Plant Outlet
In a nuclear emergency, the application of in situ spectrometers for monitoring environmental radioactivity is significantly important, as information on the type and activity of radionuclides released from the accident can be obtained quickly. However, in emergency environmental radiological monitoring, a balance between energy resolution and detecting efficiency must be considered in selecting an appropriate detector. In this study, in situ gamma spectrometry was conducted with the LaBr3 detector to determine the radioactivity of seawater at the discharging outlet of a coastal nuclear power plant in southeast China. The results show that the LaBr3 scintillator has excellent energy resolution and detection efficiency, making it a promising detector for emergency monitoring.
- 13 April 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 301 (2) , 443-450
Environmental gamma background measurements in China Jinping Underground Laboratory
- 13 April 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 301 (2) , 443-450
Environmental gamma background measurements in China Jinping Underground Laboratory