Smita Rajshekhar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Smita Rajshekhar has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Sambit Mukhopadhyay
Norfolk and Norwich University Hospital, Norwich, UK
2 shared publicationsEdward Morris
Norfolk and Norwich University Hospital, Norwich, UK
1 shared publicationUwe Klinge
Dept of General, Visceral, Transplant Surgery, University Hospital of the RWTH, Aachen, Germany
1 shared publication
Latest Publications
- 1 November 2016
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 135 (2) , 182-186
Early safety and efficacy outcomes of a novel technique of sacrocolpopexy for the treatment of apical prolapse
Objective: To assess the safety and efficacy of a modified technique of bilateral abdominal sacrocolpopexy in which both uterosacral ligaments are replaced with polyvinylidene fluoride mesh to provide support to the cervix (cervico‐sacropexy [CESA]) or vaginal vault (vagino‐sacropexy [VASA]). Methods: A retrospective observational study was undertaken of women with posthysterectomy vault prolapse or recurrent apical prolapse following previous prolapse repair who underwent bilateral sacrocolpopexy between July 1, 2013, and December 31, 2014, in a tertiary referral unit in the UK. Before surgery and 3 months afterwards, prolapse was assessed using the Pelvic Organ Prolapse Quantification scale and functional outcomes were recorded using the International Consultation on Incontinence Questionnaire for vaginal symptoms and urinary incontinence. Results: Fifty women were included. At 3 months, 47 (94%) patients reported no bulge symptoms and the mean point C was –7.6. Complications comprised bladder injury in 1 (2%) and minor wound problems in 3 (6%) patients. No mesh erosion was reported. Conclusion: Bilateral abdominal sacrocolpopexy seems to be a safe and effective option for apical prolapse. Longer‐term follow‐up is needed to detect prolapse recurrence and mesh‐related complications.
- 1 November 2016
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 135 (2) , 182-186
Early safety and efficacy outcomes of a novel technique of sacrocolpopexy for the treatment of apical prolapse
Objective: To assess the safety and efficacy of a modified technique of bilateral abdominal sacrocolpopexy in which both uterosacral ligaments are replaced with polyvinylidene fluoride mesh to provide support to the cervix (cervico‐sacropexy [CESA]) or vaginal vault (vagino‐sacropexy [VASA]). Methods: A retrospective observational study was undertaken of women with posthysterectomy vault prolapse or recurrent apical prolapse following previous prolapse repair who underwent bilateral sacrocolpopexy between July 1, 2013, and December 31, 2014, in a tertiary referral unit in the UK. Before surgery and 3 months afterwards, prolapse was assessed using the Pelvic Organ Prolapse Quantification scale and functional outcomes were recorded using the International Consultation on Incontinence Questionnaire for vaginal symptoms and urinary incontinence. Results: Fifty women were included. At 3 months, 47 (94%) patients reported no bulge symptoms and the mean point C was –7.6. Complications comprised bladder injury in 1 (2%) and minor wound problems in 3 (6%) patients. No mesh erosion was reported. Conclusion: Bilateral abdominal sacrocolpopexy seems to be a safe and effective option for apical prolapse. Longer‐term follow‐up is needed to detect prolapse recurrence and mesh‐related complications.
- 6 May 2015
- Published by Taylor & Francis in Post Reproductive Health
- Vol. 21 (2) , 69-74
Mesh for prolapse surgery: Why the fuss?
Pelvic organ prolapse is a common gynaecological problem. Surgical techniques to repair prolapse have been constantly evolving to reduce the recurrence of prolapse and need for reoperation. Grafts made of synthetic and biological materials became popular in the last decade as they were intended to provide extra support to native tissue repairs. However, serious complications related to use of synthetic meshes have been reported and there is increasing medico-legal concern about mesh use in prolapse surgery. Some mesh products already have been withdrawn from the market and the FDA has introduced stricter surveillance of new and existing products. Large randomized studies comparing mesh with non-mesh procedures are lacking which creates uncertainty for the surgeon and their patients. The small cohorts of the RCTs available with short follow-up periods just allow the conclusion that the mesh repair can be helpful in the short to medium term but unfortunately are not able to prove safety for all patients. In particular, current clinical reports cannot define for which indication what material may be superior compared to non-mesh repair. Quality control through long-term individual and national mesh registries is needed to keep a record of all surgeons using mesh and all devices being used, monitoring their effectiveness and safety data. Meshes with better biocompatibility designed specifically for use in vaginal surgery may provide superior clinical results, where the reduction of complications may allow a wider range of indications.
- 6 May 2015
- Published by Taylor & Francis in Post Reproductive Health
- Vol. 21 (2) , 69-74
Mesh for prolapse surgery: Why the fuss?
Pelvic organ prolapse is a common gynaecological problem. Surgical techniques to repair prolapse have been constantly evolving to reduce the recurrence of prolapse and need for reoperation. Grafts made of synthetic and biological materials became popular in the last decade as they were intended to provide extra support to native tissue repairs. However, serious complications related to use of synthetic meshes have been reported and there is increasing medico-legal concern about mesh use in prolapse surgery. Some mesh products already have been withdrawn from the market and the FDA has introduced stricter surveillance of new and existing products. Large randomized studies comparing mesh with non-mesh procedures are lacking which creates uncertainty for the surgeon and their patients. The small cohorts of the RCTs available with short follow-up periods just allow the conclusion that the mesh repair can be helpful in the short to medium term but unfortunately are not able to prove safety for all patients. In particular, current clinical reports cannot define for which indication what material may be superior compared to non-mesh repair. Quality control through long-term individual and national mesh registries is needed to keep a record of all surgeons using mesh and all devices being used, monitoring their effectiveness and safety data. Meshes with better biocompatibility designed specifically for use in vaginal surgery may provide superior clinical results, where the reduction of complications may allow a wider range of indications.
- 11 April 2014
- Published by Springer Nature in International Urogynecology Journal
- Vol. 25 (8) , 1141-1142
Urogynaecology digest
- 11 April 2014
- Published by Springer Nature in International Urogynecology Journal
- Vol. 25 (8) , 1141-1142
Urogynaecology digest