Kevin Paul Nichols
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kevin Paul Nichols has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
Bernhard H. Weigl
Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, Washington 98007, United States
7 shared publicationsDavid S. Boyle
5 shared publicationsBernhard H Weigl
4 shared publicationsCaitlin E Anderson
4 shared publications- Han Gardeniers
University of Twente P.O. Box 217
4 shared publications Liang Li
Department of Chemistry and Institute for Biophysical Dynamics, The University of Chicago, 929 East 57th Street, Chicago, Illinois 60637, United States
4 shared publications
Latest Publications
- Open Access
- 11 January 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Antibody Screening Results for Anti-Nucleocapsid Antibodies Towards the Development of a SARS-CoV-2 Nucleocapsid Protein Antigen Detecting Lateral Flow Assay
The global COVID-19 pandemic has created an urgent demand for large numbers of inexpensive, accurate, rapid, point-of-care diagnostic tests. Analyte-based assays are suitably inexpensive and can be rapidly mass-produced, but for sufficiently accurate performance they require highly optimized antibodies and assay conditions. We used an automated liquid handling system, customized to handle arrays of lateral flow immunoassay (LFA) tests in a high-throughput screen, to identify anti-nucleocapsid antibodies that will perform optimally in an LFA. We tested 1021 anti-nucleocapsid antibody pairs as LFA capture and detection reagents with the goal of highlighting pairs that have the greatest affinity for unique epitopes of the nucleocapsid protein of SARS-CoV-2 within the LFA format. In contrast to traditional antibody screening methods (e.g., ELISA, bio-layer interferometry), the method described here integrates real-time reaction kinetics with transport in, and immobilization directly onto, nitrocellulose. We have identified several candidate antibody pairs that are suitable for further development of an LFA for SARS-CoV-2.
- 11 January 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAntibody Screening Results for Anti-Nucleocapsid Antibodies Towards the Development of a SARS-CoV-2 Nucleocapsid Protein Antigen Detecting Lateral Flow Assay
The global COVID-19 pandemic has created an urgent demand for large numbers of inexpensive, accurate, rapid, point-of-care diagnostic tests. Analyte-based assays are suitably inexpensive and can be rapidly mass-produced, but for sufficiently accurate performance they require highly optimized antibodies and assay conditions. We used an automated liquid handling system, customized to handle arrays of lateral flow immunoassay (LFA) tests in a high-throughput screen, to identify anti-nucleocapsid antibodies that will perform optimally in an LFA. We tested 1021 anti-nucleocapsid antibody pairs as LFA capture and detection reagents with the goal of highlighting pairs that have the greatest affinity for unique epitopes of the nucleocapsid protein of SARS-CoV-2 within the LFA format. In contrast to traditional antibody screening methods (e.g., ELISA, bio-layer interferometry), the method described here integrates real-time reaction kinetics with transport in, and immobilization directly onto, nitrocellulose. We have identified several candidate antibody pairs that are suitable for further development of an LFA for SARS-CoV-2.
- Open Access
- 2 September 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Screening Antibodies Raised Against the Spike Glycoprotein of SARS-CoV-2 to Support the Development of Rapid Antigen Assays
The spike glycoprotein of SARS-CoV-2 is a highly conserved surface protein and as such may represent a good target for immunoassay detection. We screened a variety of antibodies that were reactive to the S glycoprotein in a highly sensitive liquid immunoassay format and also on paper-based or lateral flow assay (LFA) to assess their analytical performance. Our findings included significant variation in performance when using different sources of S antigen. We identified several antibody pairs that had an LOD of below 10 pg/mL in the liquid immunoassay format with the lowest being 3 pg/mL. The antibodies were highly specific to SARS-Cov-2 based on cross reactivity screening with other human CoVs. The LFA screening found some different optimal antibody pairs from the pool of candidate antibodies used but a several antibodies were observed to have high performance with either immunoassay format.
- 2 September 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessScreening Antibodies Raised Against the Spike Glycoprotein of SARS-CoV-2 to Support the Development of Rapid Antigen Assays
The spike glycoprotein of SARS-CoV-2 is a highly conserved surface protein and as such may represent a good target for immunoassay detection. We screened a variety of antibodies that were reactive to the S glycoprotein in a highly sensitive liquid immunoassay format and also on paper-based or lateral flow assay (LFA) to assess their analytical performance. Our findings included significant variation in performance when using different sources of S antigen. We identified several antibody pairs that had an LOD of below 10 pg/mL in the liquid immunoassay format with the lowest being 3 pg/mL. The antibodies were highly specific to SARS-Cov-2 based on cross reactivity screening with other human CoVs. The LFA screening found some different optimal antibody pairs from the pool of candidate antibodies used but a several antibodies were observed to have high performance with either immunoassay format.
- Open Access
- 13 August 2020
- Published by American Chemical Society (ACS) in ChemRxiv
A SARS-CoV-2 Coronavirus Nucleocapsid Protein Antigen-Detecting Lateral Flow Assay
Inexpensive, simple, rapid diagnostics are necessary for efficient detection, treatment and mitigation of COVID‑19. Currently, the primary diagnostic tool being utilized is reverse transcription polymerase chain reaction (RT-PCR). RT-PCR delivers results with good sensitivity and excellent specificity, but is expensive, prone to access challenges and is often slowed by transport to centralized testing laboratories. Antigen-based assays are inexpensive and can be rapidly mass-produced and deployed, with lateral flow assays (LFAs) being the most common inexpensive antigen test. To date, few antigen-detecting LFAs for COVID-19 have been commercialized. Herein, we present an open source LFA using commercially available antibodies and materials for the detection of SARS-CoV-2. Using an optical reader with comparable sensitivity to a visual read, the LFA yielded a Limit of Detection (LOD) of 23 TCID50/mL (95% CI of 9.1 to 37 TCID50/mL), equivalent to 1.4x105 copies/mL (95% CI of 5.5x104 to 2.3x105 copies/mL) irradiated virus in pooled nasal matrix. This LOD meets the criteria suggested by WHO for diagnosis of acute SARS-CoV-2 infection in a point of care format. A clinical evaluation and further testing is ongoing.
- 13 August 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA SARS-CoV-2 Coronavirus Nucleocapsid Protein Antigen-Detecting Lateral Flow Assay
Inexpensive, simple, rapid diagnostics are necessary for efficient detection, treatment and mitigation of COVID‑19. Currently, the primary diagnostic tool being utilized is reverse transcription polymerase chain reaction (RT-PCR). RT-PCR delivers results with good sensitivity and excellent specificity, but is expensive, prone to access challenges and is often slowed by transport to centralized testing laboratories. Antigen-based assays are inexpensive and can be rapidly mass-produced and deployed, with lateral flow assays (LFAs) being the most common inexpensive antigen test. To date, few antigen-detecting LFAs for COVID-19 have been commercialized. Herein, we present an open source LFA using commercially available antibodies and materials for the detection of SARS-CoV-2. Using an optical reader with comparable sensitivity to a visual read, the LFA yielded a Limit of Detection (LOD) of 23 TCID50/mL (95% CI of 9.1 to 37 TCID50/mL), equivalent to 1.4x105 copies/mL (95% CI of 5.5x104 to 2.3x105 copies/mL) irradiated virus in pooled nasal matrix. This LOD meets the criteria suggested by WHO for diagnosis of acute SARS-CoV-2 infection in a point of care format. A clinical evaluation and further testing is ongoing.
- Open Access
- 27 July 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Antibody Screening Results for Anti-Nucleocapsid Antibodies Towards the Development of a SARS-CoV-2 Nucleocapsid Protein Antigen Detecting Lateral Flow Assay
The global COVID-19 pandemic has created an urgent demand for accurate rapid point of care diagnostic tests. Antigen-based assays are suitably inexpensive and can be rapidly mass-produced, but sufficiently accurate performance requires highly-optimized antibodies and assay conditions. An automated liquid handling system, customized to handle lateral flow immunoassay (LFA) arrays, was used for high-throughput antibody screening of anti-nucleocapsid antibodies that will perform optimally on an LFA. Six hundred seventy-three anti-nucleocapsid antibody pairs were tested as both capture and detection reagents with the goal of finding those pairs that have the greatest affinity for unique epitopes of the nucleocapsid protein of SARS-CoV-2 while also performing optimally in an LFA format. In contrast to traditional antibody screening methods (e.g. ELISA, bio-layer interferometry), the methods described here integrate real-time LFA reaction kinetics and binding directly on nitrocellulose. We have identified several candidate antibody pairs that are suitable for further development of an LFA for SARS-CoV-2.
- 27 July 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAntibody Screening Results for Anti-Nucleocapsid Antibodies Towards the Development of a SARS-CoV-2 Nucleocapsid Protein Antigen Detecting Lateral Flow Assay
The global COVID-19 pandemic has created an urgent demand for accurate rapid point of care diagnostic tests. Antigen-based assays are suitably inexpensive and can be rapidly mass-produced, but sufficiently accurate performance requires highly-optimized antibodies and assay conditions. An automated liquid handling system, customized to handle lateral flow immunoassay (LFA) arrays, was used for high-throughput antibody screening of anti-nucleocapsid antibodies that will perform optimally on an LFA. Six hundred seventy-three anti-nucleocapsid antibody pairs were tested as both capture and detection reagents with the goal of finding those pairs that have the greatest affinity for unique epitopes of the nucleocapsid protein of SARS-CoV-2 while also performing optimally in an LFA format. In contrast to traditional antibody screening methods (e.g. ELISA, bio-layer interferometry), the methods described here integrate real-time LFA reaction kinetics and binding directly on nitrocellulose. We have identified several candidate antibody pairs that are suitable for further development of an LFA for SARS-CoV-2.
- Top Cited PapersOpen Access
- 1 July 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (16) , 11305-11309
SARS-CoV-2 Coronavirus Nucleocapsid Antigen-Detecting Half-Strip Lateral Flow Assay Toward the Development of Point of Care Tests Using Commercially Available Reagents
The SARS-CoV-2 pandemic has created an unprecedented need for rapid diagnostic testing to enable the efficient treatment and mitigation of COVID-19. The primary diagnostic tool currently employed is reverse transcription polymerase chain reaction (RT-PCR), which can have good sensitivity and excellent specificity. Unfortunately, implementation costs and logistical problems with reagents during the global SARS-CoV-2 pandemic have hindered its universal on demand adoption. Lateral flow assays (LFAs) represent a class of diagnostic that, if sufficiently clinically sensitive, may fill many of the gaps in the current RT-PCR testing regime, especially in low- and middle-income countries (LMICs). To date, many serology LFAs have been developed, though none meet the performance requirements necessary for diagnostic use cases, primarily due to the relatively long delay between infection and seroconversion. However, based on previously reported results from SARS-CoV-1, antigen-based SARS-CoV-2 assays may have significantly better clinical sensitivity than serology assays. To date, only a very small number of antigen-detecting LFAs have been developed. Development of a half-strip LFA is a useful first step in the development of any LFA format. In this paper we present a half-strip LFA using commercially available antibodies for the detection of SARS-CoV-2. We have tested this LFA in buffer and measured an LOD of 0.65 ng/ mL (95% CI of 0.53 to 0.77 ng/mL) ng/mL with recombinant antigen using an optical reader with sensitivity equivalent to a visual read. Further development, including evaluating the appropriate sample matrix, will be required for this assay approach to be made useful in a point of care setting, though this half-strip LFA may serve as a useful starting point for others developing similar tests.
- 1 July 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (16) , 11305-11309
Top Cited PapersOpen AccessSARS-CoV-2 Coronavirus Nucleocapsid Antigen-Detecting Half-Strip Lateral Flow Assay Toward the Development of Point of Care Tests Using Commercially Available Reagents
The SARS-CoV-2 pandemic has created an unprecedented need for rapid diagnostic testing to enable the efficient treatment and mitigation of COVID-19. The primary diagnostic tool currently employed is reverse transcription polymerase chain reaction (RT-PCR), which can have good sensitivity and excellent specificity. Unfortunately, implementation costs and logistical problems with reagents during the global SARS-CoV-2 pandemic have hindered its universal on demand adoption. Lateral flow assays (LFAs) represent a class of diagnostic that, if sufficiently clinically sensitive, may fill many of the gaps in the current RT-PCR testing regime, especially in low- and middle-income countries (LMICs). To date, many serology LFAs have been developed, though none meet the performance requirements necessary for diagnostic use cases, primarily due to the relatively long delay between infection and seroconversion. However, based on previously reported results from SARS-CoV-1, antigen-based SARS-CoV-2 assays may have significantly better clinical sensitivity than serology assays. To date, only a very small number of antigen-detecting LFAs have been developed. Development of a half-strip LFA is a useful first step in the development of any LFA format. In this paper we present a half-strip LFA using commercially available antibodies for the detection of SARS-CoV-2. We have tested this LFA in buffer and measured an LOD of 0.65 ng/ mL (95% CI of 0.53 to 0.77 ng/mL) ng/mL with recombinant antigen using an optical reader with sensitivity equivalent to a visual read. Further development, including evaluating the appropriate sample matrix, will be required for this assay approach to be made useful in a point of care setting, though this half-strip LFA may serve as a useful starting point for others developing similar tests.
- Open Access
- 7 May 2020
- Published by American Chemical Society (ACS) in ChemRxiv
A SARS-CoV-2 Coronavirus Antigen-Detecting Half-Strip Lateral Flow Assay Towards the Development of Point of Care Tests Using Commercially Available Reagents
The SARS-CoV-2 pandemic has created an unprecedented need for rapid diagnostic testing to enable the efficient treatment and mitigation of COVID-19. The primary diagnostic tool currently employed is reverse transcription polymerase chain reaction (RT-PCR), which can have good sensitivity and excellent specificity. Unfortunately, implementation costs and logistical problems with reagents during the global SARS-CoV-2 pandemic have hindered its universal on demand adoption. Lateral flow assays (LFAs) represent a class of diagnostic that, if sufficiently clinically sensitive, may fill many of the gaps in the current RT-PCR testing regime, especially in low- and middle-income countries (LMICs). To date, many serology LFAs have been developed, though none meet the performance requirements necessary for diagnostic use cases, primarily due to the relatively long delay between infection and seroconversion. However, based on previously reported results from SARS-CoV-1, antigen-based SARS-CoV-2 assays may have significantly better clinical sensitivity than serology assays. To date, only a very small number of antigen-detecting LFAs have been developed. Development of a half-strip LFA is a useful first step in the development of any LFA format. In this paper we present a half-strip LFA using commercially available antibodies for the detection of SARS-CoV-2. We have tested this LFA in buffer and measured an LOD of 0.62 ng/mL using an optical reader with sensitivity equivalent to a visual read. Further development, including evaluating the appropriate sample matrix, will be required for this assay approach to be made useful in a point of care setting, though this half-strip LFA may serve as a useful starting point for others developing similar tests.
- 7 May 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA SARS-CoV-2 Coronavirus Antigen-Detecting Half-Strip Lateral Flow Assay Towards the Development of Point of Care Tests Using Commercially Available Reagents
The SARS-CoV-2 pandemic has created an unprecedented need for rapid diagnostic testing to enable the efficient treatment and mitigation of COVID-19. The primary diagnostic tool currently employed is reverse transcription polymerase chain reaction (RT-PCR), which can have good sensitivity and excellent specificity. Unfortunately, implementation costs and logistical problems with reagents during the global SARS-CoV-2 pandemic have hindered its universal on demand adoption. Lateral flow assays (LFAs) represent a class of diagnostic that, if sufficiently clinically sensitive, may fill many of the gaps in the current RT-PCR testing regime, especially in low- and middle-income countries (LMICs). To date, many serology LFAs have been developed, though none meet the performance requirements necessary for diagnostic use cases, primarily due to the relatively long delay between infection and seroconversion. However, based on previously reported results from SARS-CoV-1, antigen-based SARS-CoV-2 assays may have significantly better clinical sensitivity than serology assays. To date, only a very small number of antigen-detecting LFAs have been developed. Development of a half-strip LFA is a useful first step in the development of any LFA format. In this paper we present a half-strip LFA using commercially available antibodies for the detection of SARS-CoV-2. We have tested this LFA in buffer and measured an LOD of 0.62 ng/mL using an optical reader with sensitivity equivalent to a visual read. Further development, including evaluating the appropriate sample matrix, will be required for this assay approach to be made useful in a point of care setting, though this half-strip LFA may serve as a useful starting point for others developing similar tests.
- Open Access
A Syringe-Based Biosensor to Rapidly Detect Low Levels of Escherichia Coli (ECOR13) in Drinking Water Using Engineered Bacteriophages
A sanitized drinking water supply is an unconditional requirement for public health and the overall prosperity of humanity. Potential microbial and chemical contaminants of drinking water have been identified by a joint effort between the World Health Organization (WHO) and the United Nations Children’s Fund (UNICEF), who together establish guidelines that define, in part, that the presence of Escherichia coli (E. coli) in drinking water is an indication of inadequate sanitation and a significant health risk. As E. coli is a nearly ubiquitous resident of mammalian gastrointestinal tracts, no detectable counts in 100 mL of drinking water is the standard used worldwide as an indicator of sanitation. The currently accepted EPA method relies on filtration, followed by growth on selective media, and requires 24–48 h from sample to results. In response, we developed a rapid bacteriophage-based detection assay with detection limit capabilities comparable to traditional methods in less than a quarter of the time. We coupled membrane filtration with selective enrichment using genetically engineered bacteriophages to identify less than 20 colony forming units (CFU) E. coli in 100 mL drinking water within 5 h. The combination of membrane filtration with phage infection produced a novel assay that demonstrated a rapid, selective, and sensitive detection of an indicator organism in large volumes of drinking water as recommended by the leading world regulatory authorities.
Open AccessA Syringe-Based Biosensor to Rapidly Detect Low Levels of Escherichia Coli (ECOR13) in Drinking Water Using Engineered Bacteriophages
A sanitized drinking water supply is an unconditional requirement for public health and the overall prosperity of humanity. Potential microbial and chemical contaminants of drinking water have been identified by a joint effort between the World Health Organization (WHO) and the United Nations Children’s Fund (UNICEF), who together establish guidelines that define, in part, that the presence of Escherichia coli (E. coli) in drinking water is an indication of inadequate sanitation and a significant health risk. As E. coli is a nearly ubiquitous resident of mammalian gastrointestinal tracts, no detectable counts in 100 mL of drinking water is the standard used worldwide as an indicator of sanitation. The currently accepted EPA method relies on filtration, followed by growth on selective media, and requires 24–48 h from sample to results. In response, we developed a rapid bacteriophage-based detection assay with detection limit capabilities comparable to traditional methods in less than a quarter of the time. We coupled membrane filtration with selective enrichment using genetically engineered bacteriophages to identify less than 20 colony forming units (CFU) E. coli in 100 mL drinking water within 5 h. The combination of membrane filtration with phage infection produced a novel assay that demonstrated a rapid, selective, and sensitive detection of an indicator organism in large volumes of drinking water as recommended by the leading world regulatory authorities.
- Open Access
- 30 January 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (5) , 3535-3543
Wash-Free, Digital Immunoassay in Polydisperse Droplets
Immunoassays are important for the detection of proteins to enable disease identification and monitor treatment, but many immunoassays suffer from sensitivity limitations. The development of digital assays has enabled highly sensitive biomarker detection and quantification, but the necessary devices typically require precisely controlled volumes to reduce biases in concentration estimates from compartment size variation. These constrains have led to systems that are often expensive, cumbersome, and challenging to operate, confining many digital assays to centralized laboratories. To overcome these limi-tations, we have developed a simplified digital immunoassay performed in polydisperse droplets that are prepared without any specialized equipment. This polydisperse digital droplet immunoassay (ddIA) uses proximity ligation to remove the need for wash steps and simplifies the system to a single reagent addition step. Using interleukin-8 (IL-8) as an example ana-lyte, we demonstrated the concept with samples in buffer and diluted whole blood with limits of detection of 0.793 pM and 1.54 pM, respectively. The development of a one-pot, wash-less assay greatly improves usability compared to traditional immunoassays or digital-based systems that rely heavily on wash steps and can be run with common and readily available laboratory equipment such as a heater and simple fluorescent microscope. We also developed a stochastic model with phys-ically meaningful parameters that can be utilized to optimize the assay and enable quantification without standard curves, after initial characterization of the parameters. Our polydisperse ddIA assay serves as an example of sensitive, lower-cost, and simpler immunoassays suitable for both laboratory and point-of-care applications
- 30 January 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (5) , 3535-3543
Open AccessWash-Free, Digital Immunoassay in Polydisperse Droplets
Immunoassays are important for the detection of proteins to enable disease identification and monitor treatment, but many immunoassays suffer from sensitivity limitations. The development of digital assays has enabled highly sensitive biomarker detection and quantification, but the necessary devices typically require precisely controlled volumes to reduce biases in concentration estimates from compartment size variation. These constrains have led to systems that are often expensive, cumbersome, and challenging to operate, confining many digital assays to centralized laboratories. To overcome these limi-tations, we have developed a simplified digital immunoassay performed in polydisperse droplets that are prepared without any specialized equipment. This polydisperse digital droplet immunoassay (ddIA) uses proximity ligation to remove the need for wash steps and simplifies the system to a single reagent addition step. Using interleukin-8 (IL-8) as an example ana-lyte, we demonstrated the concept with samples in buffer and diluted whole blood with limits of detection of 0.793 pM and 1.54 pM, respectively. The development of a one-pot, wash-less assay greatly improves usability compared to traditional immunoassays or digital-based systems that rely heavily on wash steps and can be run with common and readily available laboratory equipment such as a heater and simple fluorescent microscope. We also developed a stochastic model with phys-ically meaningful parameters that can be utilized to optimize the assay and enable quantification without standard curves, after initial characterization of the parameters. Our polydisperse ddIA assay serves as an example of sensitive, lower-cost, and simpler immunoassays suitable for both laboratory and point-of-care applications
- Open Access
- 24 October 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (24) , 7209-7219
General methods for quantitative interpretation of results of digital variable-volume assays
In digital assays, devices typically require precisely controlled volumes since variation can cause biases in concentration estimates. Here, we develop methods to correct bias when compartment volumes are variable.
- 24 October 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (24) , 7209-7219
Open AccessGeneral methods for quantitative interpretation of results of digital variable-volume assays
In digital assays, devices typically require precisely controlled volumes since variation can cause biases in concentration estimates. Here, we develop methods to correct bias when compartment volumes are variable.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of a simplified reader for digital droplet assays performed in limited resource settings
Digital assays are quickly becoming a gold standard method for accurately quantifying biomarkers, but systems to perform these assays still require complex, expensive equipment and highly trained users limiting their adoption in resource limited settings. In this paper, we describe the development of a simple digital assay reader that would expand access of digital assays to multiple settings.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of a simplified reader for digital droplet assays performed in limited resource settings
Digital assays are quickly becoming a gold standard method for accurately quantifying biomarkers, but systems to perform these assays still require complex, expensive equipment and highly trained users limiting their adoption in resource limited settings. In this paper, we describe the development of a simple digital assay reader that would expand access of digital assays to multiple settings.