Saifeddine Aloui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Saifeddine Aloui has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Alain Micaelli
Interactive Robotic Laboratory of CEA- LIST
2 shared publicationsAndres Ospina
LSCM within la CEA, 38054 Grenoble, France
2 shared publications- Christelle Godin
CEA-Leti Minatec Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 09, France
2 shared publications Christophe Villien
CEA, LETI MINATEC Campus 17 rue des Martyrs, 38000 Grenoble France
2 shared publications- Etienne Labyt
Mag4Health, Grenoble, France
2 shared publications Mathieu Grossard
Interactive Robotic Laboratory of CEA- LIST
2 shared publications
Latest Publications
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Capture de mouvement par mesure de distances dans un réseau corporel hétérogène
La capture de mouvement ambulatoire est un sujet en plein essor pour des applications aussi diverses que le suivi des personnes âgées, l'assistance des sportifs de haut niveau, la réhabilitation fonctionnelle, etc. Ces applications exigent que le mouvement ne soit pas contraint par un système externe, qu’il puisse être réalisé dans différentes situations, y compris en extérieur, que l’équipement soit léger et à un faible coût, qu’il soit réellement ambulatoire et sans procédure complexe de calibration.Actuellement, seuls les systèmes utilisant un exosquelette ou bien des modules inertiels (souvent combinés avec des modules magnétiques) permettent d'effectuer de la capture de mouvement de façon ambulatoire. Le poids de l’exosquelette est très important et il impose des contraintes sur les mouvements de la personne, ce qui le rend inutilisable pour certaines applications telles que le suivi de personnes âgées. La technologie inertielle est plus légère. Elle permet d'effectuer la capture du mouvement sans contrainte sur l’espace de mesure ou sur les mouvements réalisés. Par contre, elle souffre de dérives des gyromètres, et le système doit être recalibré.L'objectif de cette thèse est de développer un système de capture de mouvement de chaînes articulées, bas-coût et temps réel, réellement ambulatoire, ne nécessitant pas d'infrastructure de capture spécifique, permettant une utilisation dans de nombreux domaines applicatifs (rééducation, sport, loisirs, etc.).On s'intéresse plus particulièrement à des mesures intra-corporelles. Ainsi, tous les capteurs sont placés sur le corps et aucun dispositif externe n'est utilisé. Outre un démonstrateur final permettant de valider l'approche proposée, on s'astreint à développer également des outils qui permettent de dimensionner le système en termes de technologie, nombre et position des capteurs, mais également à évaluer différents algorithmes de fusion des données. Pour ce faire, on utilise la borne de Cramer-Rao.Le sujet est donc pluridisciplinaire. Il traite des aspects de modélisation et de dimensionnement de systèmes hybrides entièrement ambulatoires. Il étudie des algorithmes d'estimation adaptés au domaine de la capture de mouvement corps entier en traitant les problématiques d'observabilité de l'état et en tenant compte des contraintes biomécaniques pouvant être appliquées. Ainsi, un traitement adapté permet de reconstruire en temps réel la posture du sujet à partir de mesures intra-corporelles, la source étant également placée sur le corps.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Capture de mouvement par mesure de distances dans un réseau corporel hétérogène
La capture de mouvement ambulatoire est un sujet en plein essor pour des applications aussi diverses que le suivi des personnes âgées, l'assistance des sportifs de haut niveau, la réhabilitation fonctionnelle, etc. Ces applications exigent que le mouvement ne soit pas contraint par un système externe, qu’il puisse être réalisé dans différentes situations, y compris en extérieur, que l’équipement soit léger et à un faible coût, qu’il soit réellement ambulatoire et sans procédure complexe de calibration.Actuellement, seuls les systèmes utilisant un exosquelette ou bien des modules inertiels (souvent combinés avec des modules magnétiques) permettent d'effectuer de la capture de mouvement de façon ambulatoire. Le poids de l’exosquelette est très important et il impose des contraintes sur les mouvements de la personne, ce qui le rend inutilisable pour certaines applications telles que le suivi de personnes âgées. La technologie inertielle est plus légère. Elle permet d'effectuer la capture du mouvement sans contrainte sur l’espace de mesure ou sur les mouvements réalisés. Par contre, elle souffre de dérives des gyromètres, et le système doit être recalibré.L'objectif de cette thèse est de développer un système de capture de mouvement de chaînes articulées, bas-coût et temps réel, réellement ambulatoire, ne nécessitant pas d'infrastructure de capture spécifique, permettant une utilisation dans de nombreux domaines applicatifs (rééducation, sport, loisirs, etc.).On s'intéresse plus particulièrement à des mesures intra-corporelles. Ainsi, tous les capteurs sont placés sur le corps et aucun dispositif externe n'est utilisé. Outre un démonstrateur final permettant de valider l'approche proposée, on s'astreint à développer également des outils qui permettent de dimensionner le système en termes de technologie, nombre et position des capteurs, mais également à évaluer différents algorithmes de fusion des données. Pour ce faire, on utilise la borne de Cramer-Rao.Le sujet est donc pluridisciplinaire. Il traite des aspects de modélisation et de dimensionnement de systèmes hybrides entièrement ambulatoires. Il étudie des algorithmes d'estimation adaptés au domaine de la capture de mouvement corps entier en traitant les problématiques d'observabilité de l'état et en tenant compte des contraintes biomécaniques pouvant être appliquées. Ainsi, un traitement adapté permet de reconstruire en temps réel la posture du sujet à partir de mesures intra-corporelles, la source étant également placée sur le corps.
- 28 November 2022
- Published by Springer Nature in International Journal of Intelligent Robotics and Applications
- Vol. 7 (1) , 31-47
Grasp space exploration method for an underactuated gripper using human initiated primitive grasps
- 28 November 2022
- Published by Springer Nature in International Journal of Intelligent Robotics and Applications
- Vol. 7 (1) , 31-47
Grasp space exploration method for an underactuated gripper using human initiated primitive grasps
- Open Access
Analysis of Graphomotor Tests with Machine Learning Algorithms for an Early and Universal Pre-Diagnosis of Dysgraphia
Five to ten percent of school-aged children display dysgraphia, a neuro-motor disorder that causes difficulties in handwriting, which becomes a handicap in the daily life of these children. Yet, the diagnosis of dysgraphia remains tedious, subjective and dependent to the language besides stepping in late in the schooling. We propose a pre-diagnosis tool for dysgraphia using drawings called graphomotor tests. These tests are recorded using graphical tablets. We evaluate several machine-learning models and compare them to build this tool. A database comprising 305 children from the region of Grenoble, including 43 children with dysgraphia, has been established and diagnosed by specialists using the BHK test, which is the gold standard for the diagnosis of dysgraphia in France. We performed tests of classification by extracting, correcting and selecting features from the raw data collected with the tablets and achieved a maximum accuracy of 73% with cross-validation for three models. These promising results highlight the relevance of graphomotor tests to diagnose dysgraphia earlier and more broadly.
Open AccessAnalysis of Graphomotor Tests with Machine Learning Algorithms for an Early and Universal Pre-Diagnosis of Dysgraphia
Five to ten percent of school-aged children display dysgraphia, a neuro-motor disorder that causes difficulties in handwriting, which becomes a handicap in the daily life of these children. Yet, the diagnosis of dysgraphia remains tedious, subjective and dependent to the language besides stepping in late in the schooling. We propose a pre-diagnosis tool for dysgraphia using drawings called graphomotor tests. These tests are recorded using graphical tablets. We evaluate several machine-learning models and compare them to build this tool. A database comprising 305 children from the region of Grenoble, including 43 children with dysgraphia, has been established and diagnosed by specialists using the BHK test, which is the gold standard for the diagnosis of dysgraphia in France. We performed tests of classification by extracting, correcting and selecting features from the raw data collected with the tablets and achieved a maximum accuracy of 73% with cross-validation for three models. These promising results highlight the relevance of graphomotor tests to diagnose dysgraphia earlier and more broadly.
- Open Access
- 9 May 2019
- Published by Springer Nature in npj Digital Medicine
- Vol. 2 (1) , 36
Methodological issues in the creation of a diagnosis tool for dysgraphia
- 9 May 2019
- Published by Springer Nature in npj Digital Medicine
- Vol. 2 (1) , 36
Open AccessMethodological issues in the creation of a diagnosis tool for dysgraphia
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 217-222
Intrinsic tactile sensing system design for robotics manipulation
This paper presents an intrinsic tactile sensing system designed to be implemented in a robotic anthropomorphic finger, and to fulfill most of tactile sensing characteristics required to achieve dexterous manipulation of objects. The system consists of an array of four 3-axis force sensors linked to a rigid frame with a soft non-planar surface. The paper deals with the design, construction, mathematical modeling, calibration and testing of the system. The tests show high accuracy in the estimation of contact point and force components.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 217-222
Intrinsic tactile sensing system design for robotics manipulation
This paper presents an intrinsic tactile sensing system designed to be implemented in a robotic anthropomorphic finger, and to fulfill most of tactile sensing characteristics required to achieve dexterous manipulation of objects. The system consists of an array of four 3-axis force sensors linked to a rigid frame with a soft non-planar surface. The paper deals with the design, construction, mathematical modeling, calibration and testing of the system. The tests show high accuracy in the estimation of contact point and force components.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2105-2110
Tactile sensing system for robotics dexterous manipulation based on a matrix of 3-axes force sensors
This paper presents a tactile sensing system capable of measuring three force components, three torque components and the position of the centroid of the forces applied to a surface linked to an array of force-torque sensors. The paper deals with the design, the calibration, and the testing of a specific configuration of this system, where the surface is connected to an array of piezoresistive MEMs silicon 3-axis force sensors. In this configuration, only the contact position and the force components are estimated. The tests have proven that this sensor satisfies most of the characteristics needed to achieve robotic dexterous manipulation.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2105-2110
Tactile sensing system for robotics dexterous manipulation based on a matrix of 3-axes force sensors
This paper presents a tactile sensing system capable of measuring three force components, three torque components and the position of the centroid of the forces applied to a surface linked to an array of force-torque sensors. The paper deals with the design, the calibration, and the testing of a specific configuration of this system, where the surface is connected to an array of piezoresistive MEMs silicon 3-axis force sensors. In this configuration, only the contact position and the force components are estimated. The tests have proven that this sensor satisfies most of the characteristics needed to achieve robotic dexterous manipulation.
- 11 March 2014
- Published by Wiley in International Journal of Adaptive Control and Signal Processing
- Vol. 29 (4) , 407-426
A new approach for motion capture using magnetic field : models, algorithms and first results
- 11 March 2014
- Published by Wiley in International Journal of Adaptive Control and Signal Processing
- Vol. 29 (4) , 407-426
A new approach for motion capture using magnetic field : models, algorithms and first results
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 79-84
A framework for motion capture system design using Cramer-Rao lower bound
Motion capture system design is becoming an important subject since the number of its applications is steadily growing and new technologies are introduced into the market. This paper presents a theoretical approach based on Cramer-Rao Lower Bound allowing the designer to choose a configuration (i.e. modality, placement) of sensors, compare different approaches and validate the efficiency of the estimation algorithm to be used in estimating the pose of a subject. An adapted Cramer-Rao bound expression has been derived, and its computational algorithm is presented. The optimization of the design of a human machine interface system based on arm, forearm and hand pose capture using magnetic sensors is then presented as an example.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 79-84
A framework for motion capture system design using Cramer-Rao lower bound
Motion capture system design is becoming an important subject since the number of its applications is steadily growing and new technologies are introduced into the market. This paper presents a theoretical approach based on Cramer-Rao Lower Bound allowing the designer to choose a configuration (i.e. modality, placement) of sensors, compare different approaches and validate the efficiency of the estimation algorithm to be used in estimating the pose of a subject. An adapted Cramer-Rao bound expression has been derived, and its computational algorithm is presented. The optimization of the design of a human machine interface system based on arm, forearm and hand pose capture using magnetic sensors is then presented as an example.