Dan Styles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dan Styles has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ashwin Salvi
Advanced Research Projects Agency – Energy (ARPA-E), U.S. Department of Energy, 1000 Independence Avenue SW, Washington, DC 20585
2 shared publications - John Hoard
University of Michigan
2 shared publications - Dennis Assanis
Stony Brook University, 407 Administration Building, Stony Brook, NY 11794
1 shared publication Dionissios Assanis
Stony Brook University, 100 Nicolls Road, Stony Brook, NY 11794
1 shared publication- Mehdi Abarham
Ford Motor Company, 760 Town Center Drive, Dearborn, MI 48126
1 shared publication - Mitchell Bieniek
University of Michigan, 1231 Beal Avenue, Room 1105, Ann Arbor, MI 48109
1 shared publication
Latest Publications
- 5 April 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (5) , 052207
In Situ Thermophysical Properties of an Evolving Carbon Nanoparticle Based Deposit Layer Utilizing a Novel Infrared and Optical Methodology
The use of exhaust gas recirculation (EGR) in internal combustion engines has significant impacts on engine combustion and emissions. EGR can be used to reduce in-cylinder NOx production, reduce fuel consumption, and enable advanced forms of combustion. To maximize the benefits of EGR, the exhaust gases are often cooled with liquid to gas heat exchangers. However, the build up of a fouling deposit layer from exhaust particulates and volatiles results in the decrease of heat exchanger efficiency, increasing the outlet temperature of the exhaust gases and decreasing the advantages of EGR. This paper presents an experimental data from a novel in situ measurement technique in a visualization rig during the development of a 378 μm thick deposit layer. Measurements were performed every 6 hrs for up to 24 hrs. The results show a nonlinear increase in deposit thickness with an increase in layer surface area as deposition continued. Deposit surface temperature and temperature difference across the thickness of the layer was shown to increase with deposit thickness while heat transfer decreased. The provided measurements combine to produce deposit thermal conductivity. A thorough uncertainty analysis of the in situ technique is presented and suggests higher measurement accuracy at thicker deposit layers and with larger temperature differences across the layer. The interface and wall temperature measurements are identified as the strongest contributors to the measurement uncertainty. Due to instrument uncertainty, the influence of deposit thickness and temperature could not be determined. At an average deposit thickness of 378 μm and at a temperature of 100 °C, the deposit thermal conductivity was determined to be 0.044 ± 0.0062 W/m K at a 90% confidence interval based on instrument accuracy.
- 5 April 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (5) , 052207
In Situ Thermophysical Properties of an Evolving Carbon Nanoparticle Based Deposit Layer Utilizing a Novel Infrared and Optical Methodology
The use of exhaust gas recirculation (EGR) in internal combustion engines has significant impacts on engine combustion and emissions. EGR can be used to reduce in-cylinder NOx production, reduce fuel consumption, and enable advanced forms of combustion. To maximize the benefits of EGR, the exhaust gases are often cooled with liquid to gas heat exchangers. However, the build up of a fouling deposit layer from exhaust particulates and volatiles results in the decrease of heat exchanger efficiency, increasing the outlet temperature of the exhaust gases and decreasing the advantages of EGR. This paper presents an experimental data from a novel in situ measurement technique in a visualization rig during the development of a 378 μm thick deposit layer. Measurements were performed every 6 hrs for up to 24 hrs. The results show a nonlinear increase in deposit thickness with an increase in layer surface area as deposition continued. Deposit surface temperature and temperature difference across the thickness of the layer was shown to increase with deposit thickness while heat transfer decreased. The provided measurements combine to produce deposit thermal conductivity. A thorough uncertainty analysis of the in situ technique is presented and suggests higher measurement accuracy at thicker deposit layers and with larger temperature differences across the layer. The interface and wall temperature measurements are identified as the strongest contributors to the measurement uncertainty. Due to instrument uncertainty, the influence of deposit thickness and temperature could not be determined. At an average deposit thickness of 378 μm and at a temperature of 100 °C, the deposit thermal conductivity was determined to be 0.044 ± 0.0062 W/m K at a 90% confidence interval based on instrument accuracy.
- 16 May 2014
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 136 (11) , 111401
Effect of Volatiles on Soot Based Deposit Layers
The implementation of exhaust gas recirculation (EGR) coolers has recently been a widespread methodology for engine in-cylinder NOx reduction. A common problem with the use of EGR coolers is the tendency for a deposit, or fouling layer to form through thermophoresis. These deposit layers consist of soot and volatiles and reduce the effectiveness of heat exchangers at decreasing exhaust gas outlet temperatures, subsequently increasing engine out NOx emission. This paper presents results from a novel visualization rig that allows for the development of a deposit layer while providing optical and infrared access. A 24 h, 379-micron-thick deposit layer was developed and characterized with an optical microscope, an infrared camera, and a thermogravimetric analyzer. The in situ thermal conductivity of the deposit layer was calculated to be 0.047 W/mK. Volatiles from the layer were then evaporated off and the layer reanalyzed. Results suggest that the removal of volatile components affect the thermophysical properties of the deposit. Hypotheses supporting these results are presented.
- 16 May 2014
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 136 (11) , 111401
Effect of Volatiles on Soot Based Deposit Layers
The implementation of exhaust gas recirculation (EGR) coolers has recently been a widespread methodology for engine in-cylinder NOx reduction. A common problem with the use of EGR coolers is the tendency for a deposit, or fouling layer to form through thermophoresis. These deposit layers consist of soot and volatiles and reduce the effectiveness of heat exchangers at decreasing exhaust gas outlet temperatures, subsequently increasing engine out NOx emission. This paper presents results from a novel visualization rig that allows for the development of a deposit layer while providing optical and infrared access. A 24 h, 379-micron-thick deposit layer was developed and characterized with an optical microscope, an infrared camera, and a thermogravimetric analyzer. The in situ thermal conductivity of the deposit layer was calculated to be 0.047 W/mK. Volatiles from the layer were then evaporated off and the layer reanalyzed. Results suggest that the removal of volatile components affect the thermophysical properties of the deposit. Hypotheses supporting these results are presented.