Fumihide Itokawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fumihide Itokawa has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Takao Itoi
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo 160-0023, Japan
29 shared publications - Atsushi Sofuni
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
28 shared publications - Takayoshi Tsuchiya
Department of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan
20 shared publications - Toshio Kurihara
Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
20 shared publications - Fuminori Moriyasu
Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
18 shared publications Kentaro Ishii
18 shared publications
Latest Publications
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB419-AB420
Mo1389 Plastic Stent Versus Biflanged Metal Stent Placement Under EUS Guidance for the Treatment of Pancreatic Pseudocysts and Walled-off Necrosis
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB419-AB420
Mo1389 Plastic Stent Versus Biflanged Metal Stent Placement Under EUS Guidance for the Treatment of Pancreatic Pseudocysts and Walled-off Necrosis
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB184
916 Endoscopic Ultrasound-Guided Pancreatic Duct Rendezvous in Child With Traumatic PD Disruption
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB184
916 Endoscopic Ultrasound-Guided Pancreatic Duct Rendezvous in Child With Traumatic PD Disruption
- 20 April 2014
- Published by Wiley in Digestive Endoscopy
- Vol. 26 (S2) , 136-143
Single‐ and double‐balloon enteroscopy‐assisted endoscopic retrograde cholangiopancreatography in patients with Roux‐en‐Y plus hepaticojejunostomy anastomosis and Whipple resection
Background and Aim: In patients with Roux‐en‐Y hepaticojejunostomy (HJ with R‐Y) and Whipple resection, endoscopic retrograde cholangiopancreatography (ERCP) can be challenging. We report our experience with ERCP using balloon‐assisted enteroscopy (BAE) (BAE‐ERCP) in patients with HJ with R‐Y, and Whipple resection.Methods: BAE‐ERCP procedures were carried out in 62 patients (HJ with R‐Y : Whipple resection = 34:28).Results: Overall, the rates of reaching the anastomosis were 85.3% (29/34) in HJ with R‐Y and 96.4% (27/28) in Whipple resection. In terms of HJ with R‐Y, insertion success rate by standard single‐balloon enteroscopy (SBE) was 89.3% (25/28). Insertion success rate by short BAE, including SBE and double‐balloon enteroscopy (DBE), was 50% (3/6). There was a statistically significant difference of insertion success rate between standard long BE and short BE (P = 0.021). However, in the Whipple patients, insertion success rate by standard and short SBE was 93.8% (15/16) and 91.7% (11/12), respectively. Initial insertion success rate by short BAE in Whipple patients was significantly higher than in HJ with R‐Y (91.7% vs 50%, P = 0.045). Therapeutic interventions included dilation of anastomosis stricture, stone extraction, endoscopic mechanical lithotripsy, biliary stent placement, stent extraction, endoscopic nasobiliary drainage, direct cholangioscopy, and electrohydraulic lithotripsy. Our HJ with R‐Y series and Whipple series treatment success rate was 90% (18/20) and 95.0% (19/20), respectively.Conclusions: BAE‐ERCP enabled ERCP to be carried out in patients with HJ. It is considered safe and feasible. Further experience and device improvement are needed.
- 20 April 2014
- Published by Wiley in Digestive Endoscopy
- Vol. 26 (S2) , 136-143
Single‐ and double‐balloon enteroscopy‐assisted endoscopic retrograde cholangiopancreatography in patients with Roux‐en‐Y plus hepaticojejunostomy anastomosis and Whipple resection
Background and Aim: In patients with Roux‐en‐Y hepaticojejunostomy (HJ with R‐Y) and Whipple resection, endoscopic retrograde cholangiopancreatography (ERCP) can be challenging. We report our experience with ERCP using balloon‐assisted enteroscopy (BAE) (BAE‐ERCP) in patients with HJ with R‐Y, and Whipple resection.Methods: BAE‐ERCP procedures were carried out in 62 patients (HJ with R‐Y : Whipple resection = 34:28).Results: Overall, the rates of reaching the anastomosis were 85.3% (29/34) in HJ with R‐Y and 96.4% (27/28) in Whipple resection. In terms of HJ with R‐Y, insertion success rate by standard single‐balloon enteroscopy (SBE) was 89.3% (25/28). Insertion success rate by short BAE, including SBE and double‐balloon enteroscopy (DBE), was 50% (3/6). There was a statistically significant difference of insertion success rate between standard long BE and short BE (P = 0.021). However, in the Whipple patients, insertion success rate by standard and short SBE was 93.8% (15/16) and 91.7% (11/12), respectively. Initial insertion success rate by short BAE in Whipple patients was significantly higher than in HJ with R‐Y (91.7% vs 50%, P = 0.045). Therapeutic interventions included dilation of anastomosis stricture, stone extraction, endoscopic mechanical lithotripsy, biliary stent placement, stent extraction, endoscopic nasobiliary drainage, direct cholangioscopy, and electrohydraulic lithotripsy. Our HJ with R‐Y series and Whipple series treatment success rate was 90% (18/20) and 95.0% (19/20), respectively.Conclusions: BAE‐ERCP enabled ERCP to be carried out in patients with HJ. It is considered safe and feasible. Further experience and device improvement are needed.
- 20 April 2014
- Published by Wiley in Digestive Endoscopy
- Vol. 26, 144-146
Post-endoscopic retrograde cholangiopancreatography pancreatitis caused by papillary large-balloon dilation of incidental intrapapillary fistula in Roux-en-Y patients: Lesson from a case
Endoscopic papillary large-balloon dilation (EPLBD) has been popular worldwide for difficult stones. At the primary stage, EPLBD is done immediately after endoscopic sphincterotomy (ES) or after previous ES. Recently, several endoscopists have reported the feasibility and safety of EPLBD without ES and post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) as adverse events. Herein, we encountered a case of PEP in which EPLBD was carried out through a spontaneous fistula in the papillary roof, although there was no manipulation of the pancreatic duct. We learned a lesson from the present case in which possible PEP might occur during the procedure of EPLBD without ES.
- 20 April 2014
- Published by Wiley in Digestive Endoscopy
- Vol. 26, 144-146
Post-endoscopic retrograde cholangiopancreatography pancreatitis caused by papillary large-balloon dilation of incidental intrapapillary fistula in Roux-en-Y patients: Lesson from a case
Endoscopic papillary large-balloon dilation (EPLBD) has been popular worldwide for difficult stones. At the primary stage, EPLBD is done immediately after endoscopic sphincterotomy (ES) or after previous ES. Recently, several endoscopists have reported the feasibility and safety of EPLBD without ES and post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) as adverse events. Herein, we encountered a case of PEP in which EPLBD was carried out through a spontaneous fistula in the papillary roof, although there was no manipulation of the pancreatic duct. We learned a lesson from the present case in which possible PEP might occur during the procedure of EPLBD without ES.
- 22 October 2013
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 28 (11) , 1787-1793
Is the double‐guidewire technique superior to the pancreatic duct guidewire technique in cases of pancreatic duct opacification?
Pancreatic duct guidewire placement (P-GW) techniques include both the injection cannulation technique with a contrast medium and wire-guided cannulation without contrast injection for selective biliary cannulation; the latter is the so-called "double-guidewire technique" (D-GW). The aim of this study was to compare the outcomes between P-GW and D-GW for biliary cannulation. The procedures for biliary cannulation with a naïve papilla were performed in a total of 363 cases. We divided the patients chronologically, according to the time period during which the procedures were performed, into two groups: group A, P-GW performed from March 2008 to June 2009; and group B, D-GW performed from July 2009 to December 2010. The success rates and complication rates were evaluated in each group. Biliary cannulation was successful in 31 (81.6%) patients in the P-GW group and 34 patients (82.9%) in the D-GW group. The onsets of postendoscopic retrograde cholangiopancreatography pancreatitis (PEP) occurred in the P-GW and D-GW groups were four (10.5%) and three (7.3%) patients, respectively, and all were mild cases (P = 0.616). The frequency of hyperamylasemia and the serum amylase level tended to be lower in the D-GW group than in the P-GW group (P = 0.213). There was a statistically significant difference on the onsets of PEP in the GW and non-GW groups (P = 0.04, 8.9% and 1.1%, respectively). Both the D-GW and P-GW techniques were equally effective for difficult biliary cannulation. Furthermore, the complication rates, including PEP, were similar in both techniques. A prospective randomized trial is warranted.
- 22 October 2013
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 28 (11) , 1787-1793
Is the double‐guidewire technique superior to the pancreatic duct guidewire technique in cases of pancreatic duct opacification?
Pancreatic duct guidewire placement (P-GW) techniques include both the injection cannulation technique with a contrast medium and wire-guided cannulation without contrast injection for selective biliary cannulation; the latter is the so-called "double-guidewire technique" (D-GW). The aim of this study was to compare the outcomes between P-GW and D-GW for biliary cannulation. The procedures for biliary cannulation with a naïve papilla were performed in a total of 363 cases. We divided the patients chronologically, according to the time period during which the procedures were performed, into two groups: group A, P-GW performed from March 2008 to June 2009; and group B, D-GW performed from July 2009 to December 2010. The success rates and complication rates were evaluated in each group. Biliary cannulation was successful in 31 (81.6%) patients in the P-GW group and 34 patients (82.9%) in the D-GW group. The onsets of postendoscopic retrograde cholangiopancreatography pancreatitis (PEP) occurred in the P-GW and D-GW groups were four (10.5%) and three (7.3%) patients, respectively, and all were mild cases (P = 0.616). The frequency of hyperamylasemia and the serum amylase level tended to be lower in the D-GW group than in the P-GW group (P = 0.213). There was a statistically significant difference on the onsets of PEP in the GW and non-GW groups (P = 0.04, 8.9% and 1.1%, respectively). Both the D-GW and P-GW techniques were equally effective for difficult biliary cannulation. Furthermore, the complication rates, including PEP, were similar in both techniques. A prospective randomized trial is warranted.
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB314
Su1407 Safety and Effectiveness of Endoscopic Sphincterotmy Plus Large Balloon Dilation: Single Center Mid-Term Outcome
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB314
Su1407 Safety and Effectiveness of Endoscopic Sphincterotmy Plus Large Balloon Dilation: Single Center Mid-Term Outcome
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB127
66 Creation of a Choledochoduodenostomy Using a Novel Lumenal Apposition Device: First Clinical Experience
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB127
66 Creation of a Choledochoduodenostomy Using a Novel Lumenal Apposition Device: First Clinical Experience
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB373-AB374
Su1577 Endoscopic Ultrasound-Guided Pancreatic Pseudocyst With Metal Stent Appears to Be Effective and Safe Procedure
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB373-AB374
Su1577 Endoscopic Ultrasound-Guided Pancreatic Pseudocyst With Metal Stent Appears to Be Effective and Safe Procedure
- 1 May 2013
- Published by Elsevier in Gastroenterology
- Vol. 144 (5)
Sa1146 Usefulness of High-Intensity Focused Ultrasound (HIFU) Therapy for Pancreatic Cancer
- 1 May 2013
- Published by Elsevier in Gastroenterology
- Vol. 144 (5)
Sa1146 Usefulness of High-Intensity Focused Ultrasound (HIFU) Therapy for Pancreatic Cancer