Tomohisa Iwai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomohisa Iwai has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Kosuke Okuwaki
Department of Gastroenterology, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
22 shared publications - Masafumi Watanabe
Department of Gastroenterology, Kitasato University School of Medicine, Sagamihara, Japan
14 shared publications Mitsuhiro Kida
Department of Gastroenterology Kitasato University School of Medicine Sagamihara Kanagawa Japan
14 shared publications- Hiroshi Imaizumi
Department of Gastroenterology, Kitasato University School of Medicine, Sagamihara, Japan
13 shared publications - Mitsuhiro Kida
Department of Gastroenterology Kitasato University School of Medicine Sagamihara Japan
13 shared publications Hiroshi Imaizumi
Department of Gastroenterology Kitasato University School of Medicine Sagamihara Kanagawa Japan
12 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (Suppl 4) , E781-E782
Endoscopic retrieval of a migrated plastic stent after endoscopic ultrasound-guided hepaticojejunostomy
- 30 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (Suppl 4) , E781-E782
Open AccessEndoscopic retrieval of a migrated plastic stent after endoscopic ultrasound-guided hepaticojejunostomy
- 4 June 2025
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 32 (8) , 630-636
Precut Sphincterotomy is a Valuable Advanced Cannulation Technique for Difficult Biliary Duct Cannulation in Single‐Balloon Enteroscopy‐Assisted Endoscopic Retrograde Cholangiopancreatography for Surgically Altered Anatomy
Background: In single balloon‐enteroscopy‐assisted endoscopic retrograde cholangiopancreatography (SBE‐assisted ERCP) for patients with surgically altered anatomies, precut sphincterotomy is performed as an advanced cannulation technique for difficult biliary cannulation cases. This study evaluated the safety and efficacy of precut sphincterotomy.Methods: The study included patients who underwent SBE‐assisted ERCP on a naive papilla with surgically altered anatomies (excluding Billroth‐I reconstruction) from April 2015 to December 2023. The success rate of biliary cannulation and the complication incidence were analyzed retrospectively.Results: A total of 231 patients were included. Scope insertion to the duodenal papilla was possible in 204 cases (88.3%), and biliary cannulation was attempted in 198 cases (85.7%). Standard cannulation was successful in 132 cases (66.7%), while an additional 10 cases (5.1%) successfully cannulated using pancreatic guide wire‐assisted biliary cannulation. An additional 28 cases (14.1%) were successfully cannulated using precut sphincterotomy. Therefore, the overall biliary cannulation success rate was 85.9% (170 of 198 cases). The success rate of precut sphincterotomy was 66.7% (28 of 42 cases). Intraoperative bleeding caused by precut sphincterotomy occurred in 11.9%, and other complications were present in 16.7% of cases.Conclusions: Precut sphincterotomy is a one of the valuable techniques in SBE‐assisted ERCP for surgically altered anatomies.
- 4 June 2025
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 32 (8) , 630-636
Precut Sphincterotomy is a Valuable Advanced Cannulation Technique for Difficult Biliary Duct Cannulation in Single‐Balloon Enteroscopy‐Assisted Endoscopic Retrograde Cholangiopancreatography for Surgically Altered Anatomy
Background: In single balloon‐enteroscopy‐assisted endoscopic retrograde cholangiopancreatography (SBE‐assisted ERCP) for patients with surgically altered anatomies, precut sphincterotomy is performed as an advanced cannulation technique for difficult biliary cannulation cases. This study evaluated the safety and efficacy of precut sphincterotomy.Methods: The study included patients who underwent SBE‐assisted ERCP on a naive papilla with surgically altered anatomies (excluding Billroth‐I reconstruction) from April 2015 to December 2023. The success rate of biliary cannulation and the complication incidence were analyzed retrospectively.Results: A total of 231 patients were included. Scope insertion to the duodenal papilla was possible in 204 cases (88.3%), and biliary cannulation was attempted in 198 cases (85.7%). Standard cannulation was successful in 132 cases (66.7%), while an additional 10 cases (5.1%) successfully cannulated using pancreatic guide wire‐assisted biliary cannulation. An additional 28 cases (14.1%) were successfully cannulated using precut sphincterotomy. Therefore, the overall biliary cannulation success rate was 85.9% (170 of 198 cases). The success rate of precut sphincterotomy was 66.7% (28 of 42 cases). Intraoperative bleeding caused by precut sphincterotomy occurred in 11.9%, and other complications were present in 16.7% of cases.Conclusions: Precut sphincterotomy is a one of the valuable techniques in SBE‐assisted ERCP for surgically altered anatomies.
- 28 May 2025
- Published by Wiley in Journal of Gastroenterology and Hepatology
Feasibility of Endoscopic Ultrasound‐Guided Tissue Acquisition for < 20‐mm Upper Gastrointestinal Subepithelial Lesions
Background: There are few reports on the usefulness of endoscopic ultrasound‐guided tissue acquisition (EUS‐TA) for upper gastrointestinal subepithelial lesions (SELs) < 20 mm with on‐site stereomicroscopic assessment.Aim: This study is aimed at investigating the usefulness of EUS‐TA combined with on‐site stereomicroscopic assessment using fine‐needle biopsy (FNB) for SELs < 20 mm.Methods: Participants (n = 133) underwent EUS‐TA combined with on‐site stereomicroscopic assessment using a 22‐gauge FNB needle for upper gastrointestinal SELs between January 2018 and January 2022. We conducted a comparative study of diagnostic results after dividing the participants into two groups on the basis of lesion size: < 20 and ≥ 20 mm.Results: There were 42 cases in the < 20‐mm group and 91 cases in the ≥ 20‐mm group. The diagnostic yield of EUS‐TA in all cases was 97.7%, with values of 97.6% in the < 20‐mm group and 97.8% in the ≥ 20‐mm group and no significant difference between the groups. A total of 298 passes were made. The tissue sampling rate was 99.0%, and specimens with stereomicroscopically visible white cores (SVWCs) ≥ 4 mm were sampled at a rate of 87.2%. There was no significant difference in the sampling rate of specimens with SVWCs ≥ 4 mm between the groups. The diagnostic sensitivity in specimens with SVWC ≥ 4 mm was 98.5% (256/260 passes). Multivariate analysis showed that this factor significantly contributed to diagnosis (odds ratio 24.396, 95% confidence interval: 1.6596–4.7292, p < 0.001).Conclusions: EUS‐TA using a FNB needle combined with on‐site stereomicroscopic assessment is a useful diagnostic method for < 20‐mm SELs.
- 28 May 2025
- Published by Wiley in Journal of Gastroenterology and Hepatology
Feasibility of Endoscopic Ultrasound‐Guided Tissue Acquisition for < 20‐mm Upper Gastrointestinal Subepithelial Lesions
Background: There are few reports on the usefulness of endoscopic ultrasound‐guided tissue acquisition (EUS‐TA) for upper gastrointestinal subepithelial lesions (SELs) < 20 mm with on‐site stereomicroscopic assessment.Aim: This study is aimed at investigating the usefulness of EUS‐TA combined with on‐site stereomicroscopic assessment using fine‐needle biopsy (FNB) for SELs < 20 mm.Methods: Participants (n = 133) underwent EUS‐TA combined with on‐site stereomicroscopic assessment using a 22‐gauge FNB needle for upper gastrointestinal SELs between January 2018 and January 2022. We conducted a comparative study of diagnostic results after dividing the participants into two groups on the basis of lesion size: < 20 and ≥ 20 mm.Results: There were 42 cases in the < 20‐mm group and 91 cases in the ≥ 20‐mm group. The diagnostic yield of EUS‐TA in all cases was 97.7%, with values of 97.6% in the < 20‐mm group and 97.8% in the ≥ 20‐mm group and no significant difference between the groups. A total of 298 passes were made. The tissue sampling rate was 99.0%, and specimens with stereomicroscopically visible white cores (SVWCs) ≥ 4 mm were sampled at a rate of 87.2%. There was no significant difference in the sampling rate of specimens with SVWCs ≥ 4 mm between the groups. The diagnostic sensitivity in specimens with SVWC ≥ 4 mm was 98.5% (256/260 passes). Multivariate analysis showed that this factor significantly contributed to diagnosis (odds ratio 24.396, 95% confidence interval: 1.6596–4.7292, p < 0.001).Conclusions: EUS‐TA using a FNB needle combined with on‐site stereomicroscopic assessment is a useful diagnostic method for < 20‐mm SELs.
- Open Access
Safety and Efficacy of a 6‐Month Placement of a Fully Covered Self‐Expanding Metallic Stent for Refractory Benign Biliary Stricture: A Multicenter Prospective Study
Background and Aim: Managing benign biliary stricture endoscopically is complicated and challenging. This study aimed to evaluate the safety and efficacy of a 6‐month placement of a fully covered self‐expanding metallic stent for refractory benign biliary stricture.Methods: Twenty‐two patients with refractory benign biliary stricture (13 with chronic pancreatitis and 9 without) were recruited from five higher tertiary care centers. All patients received a planned 6‐month fully covered self‐expanding metallic stent placement. Primary outcomes included clinical success, technical success of stent removal, adverse events, and stricture recurrence.Results: Of the 21 cases (one case was excluded owing to malignant findings), fully covered self‐expanding metallic stent placement was successful in all cases, with contralateral bile duct plastic stents used in three patients and stents remaining in place for 6 months in 16 of 21 patients. Distal stent migration occurred in three cases, two of which had resolved strictures. Adverse events were observed in 19.0% of patients: one case of severe cholangitis, two cases of mild cholangitis, and one case of hyperplasia formation. No stent‐induced pancreatitis or cholecystitis occurred. All stents were removed successfully, and the treatment success rate was 85%. One patient experienced recurrent stricture 6.5 months post‐stent removal.Conclusions: A six‐month placement of a modified fully covered self‐expanding metallic stent effectively improved strictures and minimized stent‐induced Adverse events in patients with refractory benign biliary stricture.Trial Registration: UMIN ID: UMIN000025027
Open AccessSafety and Efficacy of a 6‐Month Placement of a Fully Covered Self‐Expanding Metallic Stent for Refractory Benign Biliary Stricture: A Multicenter Prospective Study
Background and Aim: Managing benign biliary stricture endoscopically is complicated and challenging. This study aimed to evaluate the safety and efficacy of a 6‐month placement of a fully covered self‐expanding metallic stent for refractory benign biliary stricture.Methods: Twenty‐two patients with refractory benign biliary stricture (13 with chronic pancreatitis and 9 without) were recruited from five higher tertiary care centers. All patients received a planned 6‐month fully covered self‐expanding metallic stent placement. Primary outcomes included clinical success, technical success of stent removal, adverse events, and stricture recurrence.Results: Of the 21 cases (one case was excluded owing to malignant findings), fully covered self‐expanding metallic stent placement was successful in all cases, with contralateral bile duct plastic stents used in three patients and stents remaining in place for 6 months in 16 of 21 patients. Distal stent migration occurred in three cases, two of which had resolved strictures. Adverse events were observed in 19.0% of patients: one case of severe cholangitis, two cases of mild cholangitis, and one case of hyperplasia formation. No stent‐induced pancreatitis or cholecystitis occurred. All stents were removed successfully, and the treatment success rate was 85%. One patient experienced recurrent stricture 6.5 months post‐stent removal.Conclusions: A six‐month placement of a modified fully covered self‐expanding metallic stent effectively improved strictures and minimized stent‐induced Adverse events in patients with refractory benign biliary stricture.Trial Registration: UMIN ID: UMIN000025027
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1338-E1340
Traumatic pancreatic injury successfully bridged through a giant pancreatic pseudocyst
Pancreatic injury is a rare form of abdominal trauma and usually requires surgery for deep damage with axial deviation [1] [2]. Recently, endoscopic pancreatic stenting for the disconnected pancreatic duct syndrome (DPDS) has been attempted as a minimally invasive treatment [3] [4] [5], but difficult situations are often encountered. Here, we present a case of successful rendezvous stenting through a giant pancreatic pseudocyst ([Video 1]). A 9-year-old boy fell off his bicycle and had handlebar trauma. He had a duodenal perforation and severe damage to the pancreas, resulting in DPDS ([Fig. 1]). He first underwent mesh repair surgery for duodenal perforation, and endoscopic treatment for DPDS was unsuccessful on two attempts ([Fig. 2]). Two weeks later, MRCP revealed a small pseudocyst, and conservative management was chosen. The patient developed postprandial abdominal pain and maintained on total parenteral nutrition (TPN) for 2 months. He was transferred to our hospital 2 months after the injury, still on TPN. MRCP performed at our hospital revealed that the pancreatic pseudocyst had enlarged to 45 mm ([Fig. 3]). Because single-session bridging was considered impossible, two stents were placed in the pseudocyst – one via the transpapillary route and one via EUS-guided pancreatic duct drainage – to establish two points of communication between the pseudocyst and the main pancreatic duct ([Fig. 4]). In the second session, after balloon dilation of the distal connecting part of the pancreatic duct, a guidewire inserted from the papilla of Vater was advanced across the pseudocyst into the pancreatic duct of the tail, and a transpapillary pancreatic stent was successfully placed through the pseudocyst ([Fig. 5]). To the best of our knowledge, this is the first report of successful stent bridging through a giant pancreatic pseudocyst caused by trauma. Endoscopy_UCTN_Code_TTT_1AS_2AD Article published online: 21 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1338-E1340
Open AccessTraumatic pancreatic injury successfully bridged through a giant pancreatic pseudocyst
Pancreatic injury is a rare form of abdominal trauma and usually requires surgery for deep damage with axial deviation [1] [2]. Recently, endoscopic pancreatic stenting for the disconnected pancreatic duct syndrome (DPDS) has been attempted as a minimally invasive treatment [3] [4] [5], but difficult situations are often encountered. Here, we present a case of successful rendezvous stenting through a giant pancreatic pseudocyst ([Video 1]). A 9-year-old boy fell off his bicycle and had handlebar trauma. He had a duodenal perforation and severe damage to the pancreas, resulting in DPDS ([Fig. 1]). He first underwent mesh repair surgery for duodenal perforation, and endoscopic treatment for DPDS was unsuccessful on two attempts ([Fig. 2]). Two weeks later, MRCP revealed a small pseudocyst, and conservative management was chosen. The patient developed postprandial abdominal pain and maintained on total parenteral nutrition (TPN) for 2 months. He was transferred to our hospital 2 months after the injury, still on TPN. MRCP performed at our hospital revealed that the pancreatic pseudocyst had enlarged to 45 mm ([Fig. 3]). Because single-session bridging was considered impossible, two stents were placed in the pseudocyst – one via the transpapillary route and one via EUS-guided pancreatic duct drainage – to establish two points of communication between the pseudocyst and the main pancreatic duct ([Fig. 4]). In the second session, after balloon dilation of the distal connecting part of the pancreatic duct, a guidewire inserted from the papilla of Vater was advanced across the pseudocyst into the pancreatic duct of the tail, and a transpapillary pancreatic stent was successfully placed through the pseudocyst ([Fig. 5]). To the best of our knowledge, this is the first report of successful stent bridging through a giant pancreatic pseudocyst caused by trauma. Endoscopy_UCTN_Code_TTT_1AS_2AD Article published online: 21 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 30 November 2024
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (6) , 807-813
Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Background/Aims: To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).Methods: Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.Results: We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.Conclusions: The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
- 30 November 2024
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (6) , 807-813
Open AccessEffectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Background/Aims: To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).Methods: Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.Results: We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.Conclusions: The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
- 20 November 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 40 (2) , 502-509
Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self‐Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study
Background and Aim: No prospective studies have verified the incidence of cholecystitis in patients using the covered self‐expandable metallic stent. In this study, we aimed to investigate the incidence of cholecystitis and its risk factors after low axial force covered self‐expandable metallic stent placement for malignant distal biliary obstruction.Methods: This multicenter prospective study included patients diagnosed with unresectable distal biliary obstruction between November 2019 and October 2022 who underwent low axial force covered self‐expandable metallic stent placement.Results: The technical success in the 93 analyzed patients was 100% and clinical success was 98.9%. The 70‐mm covered self‐expandable metallic stent was the most used in 53 patients (57.0%), followed by the 80‐mm type in 27 patients (29.0%), 60‐mm type in 12 patients (12.9%), and 50‐mm type in 1 patient (1.1%). Cholecystitis after covered self‐expandable metallic stent placement occurred in six patients (6.5%). The median time to onset was 46 days (range, 16–315 days), with 1 case in the early stage and five cases in the late stage. There was one mild case, one moderate case, and four severe cases. The presence of tumor involvement at the orifice of the cystic duct was identified as an independent risk factor (odds ratio, 17.0; 95% confidence interval, 1.5–195.1; p = 0.023).Conclusions: The presence of tumor involvement at the orifice of the cystic duct was an independent risk factor for the development of cholecystitis after low axial covered self‐expandable metallic stent placement.Trial registration: University Hospital Medical Information Network (UMIN) (http://www.umin.ac.jp, registration number: UMIN 000038209)
- 20 November 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 40 (2) , 502-509
Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self‐Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study
Background and Aim: No prospective studies have verified the incidence of cholecystitis in patients using the covered self‐expandable metallic stent. In this study, we aimed to investigate the incidence of cholecystitis and its risk factors after low axial force covered self‐expandable metallic stent placement for malignant distal biliary obstruction.Methods: This multicenter prospective study included patients diagnosed with unresectable distal biliary obstruction between November 2019 and October 2022 who underwent low axial force covered self‐expandable metallic stent placement.Results: The technical success in the 93 analyzed patients was 100% and clinical success was 98.9%. The 70‐mm covered self‐expandable metallic stent was the most used in 53 patients (57.0%), followed by the 80‐mm type in 27 patients (29.0%), 60‐mm type in 12 patients (12.9%), and 50‐mm type in 1 patient (1.1%). Cholecystitis after covered self‐expandable metallic stent placement occurred in six patients (6.5%). The median time to onset was 46 days (range, 16–315 days), with 1 case in the early stage and five cases in the late stage. There was one mild case, one moderate case, and four severe cases. The presence of tumor involvement at the orifice of the cystic duct was identified as an independent risk factor (odds ratio, 17.0; 95% confidence interval, 1.5–195.1; p = 0.023).Conclusions: The presence of tumor involvement at the orifice of the cystic duct was an independent risk factor for the development of cholecystitis after low axial covered self‐expandable metallic stent placement.Trial registration: University Hospital Medical Information Network (UMIN) (http://www.umin.ac.jp, registration number: UMIN 000038209)
- 6 November 2024
- Published by Springer Nature in Clinical Journal of Gastroenterology
- Vol. 18 (1) , 220-223
S-1/irinotecan/oxaliplatin chemotherapy achieved a pathological complete remission in advanced pancreatic carcinoma
Chemotherapy has been developed for many years for malignancies, including advanced pancreatic cancer, downsizing the primary site, thereby enabling complete cure with the combination of conversion surgery. Pathological complete remission from operation samples was usually identified as a promising indication for a good prognosis for many carcinomas. Several case reports consisting of pathological complete remission after chemotherapy application have been reported but no case of pathological complete remission that resulted from successful extensive resection by surgery after S-1, irinotecan, and oxaliplatin (SIROX) chemotherapy. A 48-year-old male patient was hospitalized due to abdominal pain which turned out to be a 25 mm-sized advanced uncinate process of pancreatic cancer with possible duodenum invasion and hepatic metastasis. The tumor had decreased after administering 23 sessions of modified SIROX chemotherapy, and he underwent pylorus-preserving pancreaticoduodenectomy with portal vein resection. He was successfully managed with conservative treatment and discharged 12 days postoperatively despite his postoperative weakness. He had been taking S-1 pills for 6 months and until now, 3 years postoperatively, with no relapse. The final pathology reported complete tumor regression. Therefore, we emphasize the oncologic significance of chemotherapy in the uncinate process of pancreatic cancer and the potential role of conversion surgery.
- 6 November 2024
- Published by Springer Nature in Clinical Journal of Gastroenterology
- Vol. 18 (1) , 220-223
S-1/irinotecan/oxaliplatin chemotherapy achieved a pathological complete remission in advanced pancreatic carcinoma
Chemotherapy has been developed for many years for malignancies, including advanced pancreatic cancer, downsizing the primary site, thereby enabling complete cure with the combination of conversion surgery. Pathological complete remission from operation samples was usually identified as a promising indication for a good prognosis for many carcinomas. Several case reports consisting of pathological complete remission after chemotherapy application have been reported but no case of pathological complete remission that resulted from successful extensive resection by surgery after S-1, irinotecan, and oxaliplatin (SIROX) chemotherapy. A 48-year-old male patient was hospitalized due to abdominal pain which turned out to be a 25 mm-sized advanced uncinate process of pancreatic cancer with possible duodenum invasion and hepatic metastasis. The tumor had decreased after administering 23 sessions of modified SIROX chemotherapy, and he underwent pylorus-preserving pancreaticoduodenectomy with portal vein resection. He was successfully managed with conservative treatment and discharged 12 days postoperatively despite his postoperative weakness. He had been taking S-1 pills for 6 months and until now, 3 years postoperatively, with no relapse. The final pathology reported complete tumor regression. Therefore, we emphasize the oncologic significance of chemotherapy in the uncinate process of pancreatic cancer and the potential role of conversion surgery.
- 15 May 2024
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 69 (7) , 2567-2572
Endoscopic Ultrasound-Guided Tissue Acquisition Using Fork-Tip Needle for Subepithelial Lesions: A Single-Center Validation Study
Background The cutoff value for stereomicroscopic on-site evaluation (SOSE) in endoscopic ultrasound-guided tissue acquisition (EUS-TA) has high diagnostic sensitivity when a Franseen needle is employed for upper gastrointestinal subepithelial lesions (SELs) (stereomicroscopically visible white core [SVWC] ≥ 4 mm). Aim We aimed to determine whether high diagnostic sensitivity could be obtained when EUS-TA was performed using a Fork-tip needle. Methods Twenty-one patients were prospectively registered. Patients underwent EUS-TA using a Fork-tip needle for upper gastrointestinal SELs at Kitasato University Hospital between January and November 2022. Punctures were made twice using the needle, and SOSE was conducted for each specimen. Blood and physical examination were performed to assess adverse events. Pathological diagnosis was made using hematoxylin and eosin-stained sections and immunohistochemical staining. Statistical comparisons were completed using Fisher’s exact tests. Results The diagnostic rate of EUS-TA was 100% (21/21 cases). The final diagnosis was gastrointestinal stromal tumor in 17 (81.0%) and leiomyoma in 4 (19.0%) patients. SOSE was conducted on all 42 punctures, and the tissue sampling rate was 100% (42/42 punctures). Specimens with SVWC ≥ 4 mm were collected in 97.6% punctures (41/42 punctures) and the diagnostic sensitivity for these specimens was 100% (41/41 punctures), which is significantly higher (p < 0.0238) compared to the absence of cutoff value (diagnostic sensitivity of 0%). No EUS-TA-related adverse events occurred. Conclusions EUS-TA combined with SOSE for upper gastrointestinal SEL using a fork-tip needle had a high diagnostic rate, and the cutoff value of SVWC ≥ 4 mm had high diagnostic sensitivity.
- 15 May 2024
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 69 (7) , 2567-2572
Endoscopic Ultrasound-Guided Tissue Acquisition Using Fork-Tip Needle for Subepithelial Lesions: A Single-Center Validation Study
Background The cutoff value for stereomicroscopic on-site evaluation (SOSE) in endoscopic ultrasound-guided tissue acquisition (EUS-TA) has high diagnostic sensitivity when a Franseen needle is employed for upper gastrointestinal subepithelial lesions (SELs) (stereomicroscopically visible white core [SVWC] ≥ 4 mm). Aim We aimed to determine whether high diagnostic sensitivity could be obtained when EUS-TA was performed using a Fork-tip needle. Methods Twenty-one patients were prospectively registered. Patients underwent EUS-TA using a Fork-tip needle for upper gastrointestinal SELs at Kitasato University Hospital between January and November 2022. Punctures were made twice using the needle, and SOSE was conducted for each specimen. Blood and physical examination were performed to assess adverse events. Pathological diagnosis was made using hematoxylin and eosin-stained sections and immunohistochemical staining. Statistical comparisons were completed using Fisher’s exact tests. Results The diagnostic rate of EUS-TA was 100% (21/21 cases). The final diagnosis was gastrointestinal stromal tumor in 17 (81.0%) and leiomyoma in 4 (19.0%) patients. SOSE was conducted on all 42 punctures, and the tissue sampling rate was 100% (42/42 punctures). Specimens with SVWC ≥ 4 mm were collected in 97.6% punctures (41/42 punctures) and the diagnostic sensitivity for these specimens was 100% (41/41 punctures), which is significantly higher (p < 0.0238) compared to the absence of cutoff value (diagnostic sensitivity of 0%). No EUS-TA-related adverse events occurred. Conclusions EUS-TA combined with SOSE for upper gastrointestinal SEL using a fork-tip needle had a high diagnostic rate, and the cutoff value of SVWC ≥ 4 mm had high diagnostic sensitivity.
- Open Access
- 30 January 2024
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (1) , 89-95
Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions
Background/Aims: In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs).Methods: In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA’s diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs.Results: The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture.Conclusions: Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.
- 30 January 2024
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (1) , 89-95
Open AccessStereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions
Background/Aims: In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs).Methods: In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA’s diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs.Results: The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture.Conclusions: Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.