Mohammad Ali Ardekani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Ali Ardekani has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
F. Farhani
Department of Mechanical Engineering, Iranian Research Organization for Science and Technology (IROST), Tehran, Islamic Republic of Iran
1 shared publicationFoad Farhani
Assistant Professor, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
1 shared publicationM. Masoudi Motlagh
Fara Sanjesh Saba Co. (F.S.S.), P.O. Box 14749-34193, Tehran, Iran
1 shared publicationM. Mazidi
Department of Mechanical Engineering, Iranian Research Organization for Science and Technology (IROST), Tehran, Islamic Republic of Iran
1 shared publicationMohsen Mazidi
Instructor, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
1 shared publication
Latest Publications
- 10 September 2014
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 28 (4) , 344-353
Effects of Cross Wind Conditions on Efficiency of Heller Dry Cooling Tower
Performance of a Heller cooling tower under wind conditions has been investigated by measuring wind velocity and its direction around the tower and inlet and outlet water flow rates and temperatures. Results show that air suction at the tower prevents flow separation at its periphery. The tower front cooling sectors experience better airflow distribution compared to sectors parallel to wind direction, which improves their thermal performance by about 20% compared to still-air conditions. Airflow pattern around the tower at different distances shows that wind tangential velocity at corner sectors is four times the velocity at the reference point, decreasing air pressure and tower suction.
- 10 September 2014
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 28 (4) , 344-353
Effects of Cross Wind Conditions on Efficiency of Heller Dry Cooling Tower
Performance of a Heller cooling tower under wind conditions has been investigated by measuring wind velocity and its direction around the tower and inlet and outlet water flow rates and temperatures. Results show that air suction at the tower prevents flow separation at its periphery. The tower front cooling sectors experience better airflow distribution compared to sectors parallel to wind direction, which improves their thermal performance by about 20% compared to still-air conditions. Airflow pattern around the tower at different distances shows that wind tangential velocity at corner sectors is four times the velocity at the reference point, decreasing air pressure and tower suction.
- Open Access
- 1 September 2014
- Vol. 45 (1) , 1-8
Effect of Wind on Thermal Performance of Heller Dry Cooling Tower
- 1 September 2014
- Vol. 45 (1) , 1-8
Open AccessEffect of Wind on Thermal Performance of Heller Dry Cooling Tower
- 31 January 2010
- Published by Elsevier in Measurement
- Vol. 43 (1) , 31-38
Ordinary hot-wire/hot-film method for spirography application
- 31 January 2010
- Published by Elsevier in Measurement
- Vol. 43 (1) , 31-38
Ordinary hot-wire/hot-film method for spirography application