Walter Nei Lopes dos Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Walter Nei Lopes dos Santos has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Dannuza D. Cavalcante
Instituto de Química, Grupo de Pesquisa e Desenvolvimento em Química Analítica, Universidade Federal da Bahia, Salvador, Brazil
2 shared publications- Erik Galvão Paranhos da Silva
Biotransformation and Organic Biocatalysis Research Group, Department of Exact Sciences, State University of Santa Cruz, Ilhéus 45654-370, Bahia, Brazil
2 shared publications Geovani Cardoso Brandão
Universidade do Estado da Bahia, Departamento de Ciências Exatas e da Terra, Salvador, Brazil
2 shared publicationsLucas Almir Cavalcante Minho
Instituto de Química, Universidade federal da Bahia (UFBA), R. Barão de Jeremboabo, 147, Salvador, Bahia, Brazil
2 shared publicationsAline R. Borges
Universidade Federal do Rio Grande do Sul, Instituto de Química , Av. Bento Gonçalves 9500, 91501-970 Porto Alegre-RS, Brazil
1 shared publication- Ana Maria Pinto dos Santos
Universidade Federal da Bahia
1 shared publication
Latest Publications
- 23 March 2025
- Published by Elsevier in Food Chemistry
- Vol. 482, 144001
Robust DEEP heterogeneous ensemble and META-learning for honey authentication
- 23 March 2025
- Published by Elsevier in Food Chemistry
- Vol. 482, 144001
Robust DEEP heterogeneous ensemble and META-learning for honey authentication
- 29 May 2023
- Published by Springer Nature in Food Analytical Methods
- Vol. 16 (7) , 1261-1270
A Method Based on Digital Image Colorimetry for Determination of Total Phenolic Content in Fruits
- 29 May 2023
- Published by Springer Nature in Food Analytical Methods
- Vol. 16 (7) , 1261-1270
A Method Based on Digital Image Colorimetry for Determination of Total Phenolic Content in Fruits
- Open Access
- 1 January 2020
- Published by Brazilian Journal of Development in Brazilian Journal of Development
- Vol. 6 (4) , 21576-21597
Screening of minerals, proximate composition and physico-chemical characteristics in the discrimination of Oiti (Licania tomentosa (Benth.) Fritsch.) using Kohonen self-organizing maps, PCA and HCA
Screening of minerals, proximate composition and physico-chemical characteristics in the discrimination of Oiti (Licania tomentosa (Benth.) Fritsch.) using Kohonen self-organizing maps, PCA and HCA / Triagem de minerais, composição centesimal e características físico-químicas na discriminação de Oiti (Licania tomentosa (Benth.) Fritsch.) usando mapas auto-organizados de Kohonen, PCA e HCA
- 1 January 2020
- Published by Brazilian Journal of Development in Brazilian Journal of Development
- Vol. 6 (4) , 21576-21597
Open AccessScreening of minerals, proximate composition and physico-chemical characteristics in the discrimination of Oiti (Licania tomentosa (Benth.) Fritsch.) using Kohonen self-organizing maps, PCA and HCA
Screening of minerals, proximate composition and physico-chemical characteristics in the discrimination of Oiti (Licania tomentosa (Benth.) Fritsch.) using Kohonen self-organizing maps, PCA and HCA / Triagem de minerais, composição centesimal e características físico-químicas na discriminação de Oiti (Licania tomentosa (Benth.) Fritsch.) usando mapas auto-organizados de Kohonen, PCA e HCA
- 1 June 2019
- Published by Elsevier in Microchemical Journal
- Vol. 147, 102-111
Cellulose-coated CoFe2O4 nanoparticles as an adsorbent for extraction and preconcentration of bioactive compounds in vinegars
- 1 June 2019
- Published by Elsevier in Microchemical Journal
- Vol. 147, 102-111
Cellulose-coated CoFe2O4 nanoparticles as an adsorbent for extraction and preconcentration of bioactive compounds in vinegars
- 27 April 2014
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 186 (8) , 5027-5032
Evaluation of optimal conditions for determination of low selenium content in shellfish samples collected at Todos os Santos Bay, Bahia, Brazil using HG-AFS
This work proposes a procedure for the determination of total selenium content in shellfish after digestion of samples in block using cold finger system and detection using atomic fluorescent spectrometry coupled hydride generation (HG AFS). The optimal conditions for HG such as effect and volume of prereduction KBr 10 % (m/v) (1.0 and 2.0 ml) and concentration of hydrochloric acid (3.0 and 6.0 mol L−1) were evaluated. The best results were obtained using 3 mL of HCl (6 mol L−1) and 1 mL of KBr 10 % (m/v), followed by 30 min of prereduction for the volume of 1 mL of the digested sample. The precision and accuracy were assessed by the analysis of the Certified Reference Material NIST 1566b. Under the optimized conditions, the detection and quantification limits were 6.06 and 21.21 μg kg−1, respectively. The developed method was applied to samples of shellfish (oysters, clams, and mussels) collected at Todos os Santos Bay, Bahia, Brazil. Selenium concentrations ranged from 0.23 ± 0.02 to 3.70 ± 0.27 mg kg−1 for Mytella guyanensis and Anomalocardia brasiliana, respectively. The developed method proved to be accurate, precise, cheap, fast, and could be used for monitoring Se in shellfish samples.
- 27 April 2014
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 186 (8) , 5027-5032
Evaluation of optimal conditions for determination of low selenium content in shellfish samples collected at Todos os Santos Bay, Bahia, Brazil using HG-AFS
This work proposes a procedure for the determination of total selenium content in shellfish after digestion of samples in block using cold finger system and detection using atomic fluorescent spectrometry coupled hydride generation (HG AFS). The optimal conditions for HG such as effect and volume of prereduction KBr 10 % (m/v) (1.0 and 2.0 ml) and concentration of hydrochloric acid (3.0 and 6.0 mol L−1) were evaluated. The best results were obtained using 3 mL of HCl (6 mol L−1) and 1 mL of KBr 10 % (m/v), followed by 30 min of prereduction for the volume of 1 mL of the digested sample. The precision and accuracy were assessed by the analysis of the Certified Reference Material NIST 1566b. Under the optimized conditions, the detection and quantification limits were 6.06 and 21.21 μg kg−1, respectively. The developed method was applied to samples of shellfish (oysters, clams, and mussels) collected at Todos os Santos Bay, Bahia, Brazil. Selenium concentrations ranged from 0.23 ± 0.02 to 3.70 ± 0.27 mg kg−1 for Mytella guyanensis and Anomalocardia brasiliana, respectively. The developed method proved to be accurate, precise, cheap, fast, and could be used for monitoring Se in shellfish samples.
- 16 October 2012
- Published by Springer Nature in Food Analytical Methods
- Vol. 6 (4) , 1128-1132
Slurry Sampling and HG AFS for the Determination of Total Arsenic in Rice Samples
- 16 October 2012
- Published by Springer Nature in Food Analytical Methods
- Vol. 6 (4) , 1128-1132
Slurry Sampling and HG AFS for the Determination of Total Arsenic in Rice Samples
- 28 October 2011
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 91 (15) , 1425-1435
On-line simultaneous pre-concentration procedure for the determination of cadmium and lead in drinking water employing sequential multi-element flame atomic absorption spectrometry
An on-line pre-concentration system for the sequential determination of cadmium and lead in drinking water by using fast sequential flame atomic absorption spectrometry (FS-FAAS) is proposed in this paper. Two minicolums of polyurethane foam loaded with 2-(6-methyl-2-benzothiazolylazo)-orcinol (Me-BTAO) were used as sorptive pre-concentration media for cadmium and lead. The analytical procedure involves the quantitative uptake of both analyte species by on-column chelation with Me-BTAO during sample loading followed by sequential elution of the analytes with 1.0 mol L−1 hydrochloric acid and determination by FS-FAAS. The optimisation of the entire analytical procedure was performed using a Box–Behnken multivariate design utilising the sampling flow rate, sample pH and buffer concentration as experimental variables. The proposed flow-based method featured detection limits (3σ) of 0.08 and 0.51 µg L−1 for cadmium and lead, respectively, precision expressed as relative standard deviation (RSD) of 1.63% and 3.87% (n = 7) for cadmium at the 2.0 µg L−1 and 10.0 µg L−1 levels, respectively, and RSD of 6.34% and 3.26% (n = 7) for lead at the 5.0 µg L−1 and 30.0 µg L−1 levels, respectively. The enrichment factors achieved were 38.6 and 30.0 for cadmium and lead, respectively, using a sample volume of 10.0 mL. The sampling frequency was 45 samples per hour. The accuracy was confirmed by analysis of a certified reference material, namely, SRM 1643d (Trace elements in natural water). The optimised method was applied to the determination of cadmium and lead in drinking water samples collected in Santo Amaro da Purificação City, Bahia, Brazil.
- 28 October 2011
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 91 (15) , 1425-1435
On-line simultaneous pre-concentration procedure for the determination of cadmium and lead in drinking water employing sequential multi-element flame atomic absorption spectrometry
An on-line pre-concentration system for the sequential determination of cadmium and lead in drinking water by using fast sequential flame atomic absorption spectrometry (FS-FAAS) is proposed in this paper. Two minicolums of polyurethane foam loaded with 2-(6-methyl-2-benzothiazolylazo)-orcinol (Me-BTAO) were used as sorptive pre-concentration media for cadmium and lead. The analytical procedure involves the quantitative uptake of both analyte species by on-column chelation with Me-BTAO during sample loading followed by sequential elution of the analytes with 1.0 mol L−1 hydrochloric acid and determination by FS-FAAS. The optimisation of the entire analytical procedure was performed using a Box–Behnken multivariate design utilising the sampling flow rate, sample pH and buffer concentration as experimental variables. The proposed flow-based method featured detection limits (3σ) of 0.08 and 0.51 µg L−1 for cadmium and lead, respectively, precision expressed as relative standard deviation (RSD) of 1.63% and 3.87% (n = 7) for cadmium at the 2.0 µg L−1 and 10.0 µg L−1 levels, respectively, and RSD of 6.34% and 3.26% (n = 7) for lead at the 5.0 µg L−1 and 30.0 µg L−1 levels, respectively. The enrichment factors achieved were 38.6 and 30.0 for cadmium and lead, respectively, using a sample volume of 10.0 mL. The sampling frequency was 45 samples per hour. The accuracy was confirmed by analysis of a certified reference material, namely, SRM 1643d (Trace elements in natural water). The optimised method was applied to the determination of cadmium and lead in drinking water samples collected in Santo Amaro da Purificação City, Bahia, Brazil.
- 18 August 2011
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 91 (15) , 1447-1452
Cloud point extraction for the determination of cadmium and lead employing sequential multi-element flame atomic absorption spectrometry
A cloud point extraction procedure for pre-concentration and determination of cadmium and lead in drinking water using sequential multi-element flame atomic absorption spectrometry is described. 4-(2-thiazolylazo)-orcinol (TAO) has been used as complexing agent and the micellar phase was obtained using the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) and centrifugation. The conditions for reaction and extraction (surfactant concentration, reagent concentration, effect of incubation time, etc) were studied and the analytical characteristics of the method were determined. The method allows the determination of cadmium and lead with quantification limits of 0.30 µg L−1 and 2.6 µg L−1, respectively. A precision expressed as relative standard deviation (RSD, n = 10) of 2.3% and 2.6% has been obtained for cadmium concentrations of 10 µg L−1 and 30 µg L−1, respectively, and RSD of 1.3% and 1.7% for lead concentrations of 10 µg L−1 and 30 µg L−1, respectively. The accuracy was confirmed by analysis of a natural water certified reference material. The method has been applied for the determination of cadmium and lead in drinking water samples collected in the cities of Ilhéus and Itabuna, Brazil. Recovery tests have also been performed for some samples, and results varied from 96 to 105% for cadmium and 97 to 106% for lead. The cadmium and lead concentrations found in these samples were always lower than the permissible maximum levels stipulated by World Health Organization and the Brazilian Government.
- 18 August 2011
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 91 (15) , 1447-1452
Cloud point extraction for the determination of cadmium and lead employing sequential multi-element flame atomic absorption spectrometry
A cloud point extraction procedure for pre-concentration and determination of cadmium and lead in drinking water using sequential multi-element flame atomic absorption spectrometry is described. 4-(2-thiazolylazo)-orcinol (TAO) has been used as complexing agent and the micellar phase was obtained using the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) and centrifugation. The conditions for reaction and extraction (surfactant concentration, reagent concentration, effect of incubation time, etc) were studied and the analytical characteristics of the method were determined. The method allows the determination of cadmium and lead with quantification limits of 0.30 µg L−1 and 2.6 µg L−1, respectively. A precision expressed as relative standard deviation (RSD, n = 10) of 2.3% and 2.6% has been obtained for cadmium concentrations of 10 µg L−1 and 30 µg L−1, respectively, and RSD of 1.3% and 1.7% for lead concentrations of 10 µg L−1 and 30 µg L−1, respectively. The accuracy was confirmed by analysis of a natural water certified reference material. The method has been applied for the determination of cadmium and lead in drinking water samples collected in the cities of Ilhéus and Itabuna, Brazil. Recovery tests have also been performed for some samples, and results varied from 96 to 105% for cadmium and 97 to 106% for lead. The cadmium and lead concentrations found in these samples were always lower than the permissible maximum levels stipulated by World Health Organization and the Brazilian Government.