Susan S. Glenney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Susan S. Glenney has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Richard W. Bohannon
Department of Kinesiology, Neag School of Education, University of Connecticut, Storrs, CT, USA
2 shared publicationsRobert O. Pritchard
Program in Physical Therapy, Department of Kinesiology, Neag School of Education, University of Connecticut, Storrs, CT, USA
1 shared publication
Latest Publications
- Top Cited Papers
- 5 May 2014
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 20 (4) , 295-300
Minimal clinically important difference for change in comfortable gait speed of adults with pathology: a systematic review
Rationale, aims and objectives: Walking speed is an important performance variable, but information on the minimal clinically important difference (MCID) for the measure has not been consolidated. In this review, we aimed to summarize information on the MCID for change in comfortable gait speed measurements for patients with pathology.Methods: Relevant literature was identified by searches of four databases (PubMed, Web of Knowledge, CINAHL and Scopus), hand searches and consultation with an expert. Inclusion required that articles reported a MCID for comfortable gait speed measurements. Articles were excluded if the MCID was not determined using receiver operating characteristic (ROC) curve analysis. Articles were abstracted for information on participants, interventions, gait speed documentation and the determination of MCID. Quality was assessed using a hybrid 9‐item (0–18 point) instrument.Results: Seven articles were selected based on inclusion and exclusion criteria. The populations studied included stroke (n = 3), hip fracture (n = 2), multiple sclerosis (n = 1) and mixed (n = 1). Using 13 different anchors the studies reported MCIDs of 0.08–0.26 m s−1. All but three of these MCIDs were between 0.10 and 0.20 m s−1. All MCIDs for which the area under the ROC curve exceeded 0.70 were between 0.10 and 0.17 m s−1.Conclusions: Changes in gait speed of 0.10 to 0.20 m s−1 may be important across multiple patient groups.
- 5 May 2014
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 20 (4) , 295-300
Top Cited PapersMinimal clinically important difference for change in comfortable gait speed of adults with pathology: a systematic review
Rationale, aims and objectives: Walking speed is an important performance variable, but information on the minimal clinically important difference (MCID) for the measure has not been consolidated. In this review, we aimed to summarize information on the MCID for change in comfortable gait speed measurements for patients with pathology.Methods: Relevant literature was identified by searches of four databases (PubMed, Web of Knowledge, CINAHL and Scopus), hand searches and consultation with an expert. Inclusion required that articles reported a MCID for comfortable gait speed measurements. Articles were excluded if the MCID was not determined using receiver operating characteristic (ROC) curve analysis. Articles were abstracted for information on participants, interventions, gait speed documentation and the determination of MCID. Quality was assessed using a hybrid 9‐item (0–18 point) instrument.Results: Seven articles were selected based on inclusion and exclusion criteria. The populations studied included stroke (n = 3), hip fracture (n = 2), multiple sclerosis (n = 1) and mixed (n = 1). Using 13 different anchors the studies reported MCIDs of 0.08–0.26 m s−1. All but three of these MCIDs were between 0.10 and 0.20 m s−1. All MCIDs for which the area under the ROC curve exceeded 0.70 were between 0.10 and 0.17 m s−1.Conclusions: Changes in gait speed of 0.10 to 0.20 m s−1 may be important across multiple patient groups.
- 1 November 2013
- Published by SAGE Publications in Isokinetics and Exercise Science
- Vol. 21 (4) , 325-329
Portable belt-stabilized hand-held dynamometry set-up for measuring knee extension force
The purpose of this paper is to describe a portable belt-stabilized hand-held dynamometry (HHD) set-up for measuring knee extension force and to compare the magnitude and reliability of forces obtained with the set-up to those obtained without belt-stabilization. Measures for single-limb knee extension force were obtained via HHD from 16 young participants by 2 testers of substantially different strength. Measurements were obtained during 2 sessions 1 week apart. Testing was performed with participants in a bariatric chair – with and without HHD belt-stabilization. Data from the first session were used to compare the magnitude of knee extension forces. Data from both sessions were used to examine reliability via intraclass correlation coefficients (ICCs) and Bland-Altman plots. Forces measured with belt-stabilization were significantly (p< 0.001) higher than those measured without belt-stabilization. The differences were greater for male participants (p=0.006) and the female tester(p=0.001). Intertester reliability was poor for measurements obtained without belt-stabilization (ICC=0.17) but good for measurements obtained with belt-stabilization (ICC=0.84). Differences between testers increased with the magnitude of force measured when no belt-stabilization was provided but not when belt-stabilization was used. Test-retest reliability was good when belt-stabilization was employed (ICC=0.87 and 0.92). When belt-stabilization was not used, the test-retest reliability was acceptable for the male tester (ICC=0.77) but not the female tester (ICC=0.50). In conclusion, the set-up examined is affordable, portable and easy to assemble. It allows for rapid testing of knee extension strength. With HHD belt-stabilization, the set-up can be recommended for clinicians and researchers requiring objective measures of knee extension strength in diverse settings.
- 1 November 2013
- Published by SAGE Publications in Isokinetics and Exercise Science
- Vol. 21 (4) , 325-329
Portable belt-stabilized hand-held dynamometry set-up for measuring knee extension force
The purpose of this paper is to describe a portable belt-stabilized hand-held dynamometry (HHD) set-up for measuring knee extension force and to compare the magnitude and reliability of forces obtained with the set-up to those obtained without belt-stabilization. Measures for single-limb knee extension force were obtained via HHD from 16 young participants by 2 testers of substantially different strength. Measurements were obtained during 2 sessions 1 week apart. Testing was performed with participants in a bariatric chair – with and without HHD belt-stabilization. Data from the first session were used to compare the magnitude of knee extension forces. Data from both sessions were used to examine reliability via intraclass correlation coefficients (ICCs) and Bland-Altman plots. Forces measured with belt-stabilization were significantly (p< 0.001) higher than those measured without belt-stabilization. The differences were greater for male participants (p=0.006) and the female tester(p=0.001). Intertester reliability was poor for measurements obtained without belt-stabilization (ICC=0.17) but good for measurements obtained with belt-stabilization (ICC=0.84). Differences between testers increased with the magnitude of force measured when no belt-stabilization was provided but not when belt-stabilization was used. Test-retest reliability was good when belt-stabilization was employed (ICC=0.87 and 0.92). When belt-stabilization was not used, the test-retest reliability was acceptable for the male tester (ICC=0.77) but not the female tester (ICC=0.50). In conclusion, the set-up examined is affordable, portable and easy to assemble. It allows for rapid testing of knee extension strength. With HHD belt-stabilization, the set-up can be recommended for clinicians and researchers requiring objective measures of knee extension strength in diverse settings.