Tânia Claro
Research Subjects
Tânia Claro has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hilary Humphreys
Department of Clinical Microbiology, the Royal College of Surgeons in Ireland University of Medicine and Health Sciences, Dublin, Ireland
3 shared publications - Stephen Daniels
Dublin City Univ, Sch Elect Engn, Nanomat Proc Lab, Dublin 9, Ireland
2 shared publications - Deirdre Fitzgerald-Hughes
Clinical Microbiology, Royal College of Surgeons in Ireland, RCSI Education and Research, Beaumont Hospital, Beaumont, Dublin, D09YD60, Ireland
1 shared publication Niall O’cOnnor
School of Electronic Engineering and National Centre for Plasma Science Technology,Dublin City University,Dublin,Ireland
1 shared publicationOrla Cahill
School of Electronic Engineering and National Centre for Plasma Science Technology, Dublin City University
1 shared publicationOrla J. Cahill
School of Electronic Engineering and National Centre for Plasma Science Technology,Dublin City University,Dublin,Ireland
1 shared publication
Latest Publications
- 17 March 2015
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 36 (6) , 742-744
Cold-Air Atmospheric Pressure Plasma Against Clostridium difficile Spores: A Potential Alternative for the Decontamination of Hospital Inanimate Surfaces
Clostridium difficile spores survive for months on environmental surfaces and are highly resistant to decontamination. We evaluated the effect of cold-air plasma against C. difficile spores. The single-jet had no effect while the multi-jet achieved 2–3 log10 reductions in spore counts and may augment traditional decontamination.Infect Control Hosp Epidemiol 2015;00(0):1–3
- 17 March 2015
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 36 (6) , 742-744
Cold-Air Atmospheric Pressure Plasma Against Clostridium difficile Spores: A Potential Alternative for the Decontamination of Hospital Inanimate Surfaces
Clostridium difficile spores survive for months on environmental surfaces and are highly resistant to decontamination. We evaluated the effect of cold-air plasma against C. difficile spores. The single-jet had no effect while the multi-jet achieved 2–3 log10 reductions in spore counts and may augment traditional decontamination.Infect Control Hosp Epidemiol 2015;00(0):1–3
- Open Access
- 1 September 2014
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 52 (9) , 3426-3428
Detecting Clostridium difficile Spores from Inanimate Surfaces of the Hospital Environment: Which Method Is Best?
The recovery of Clostridium difficile spores from hospital surfaces was assessed using rayon swabs, flocked swabs, and contact plates. The contact plate method was less laborious, achieved higher recovery percentages, and detected spores at lower inocula than swabs. Rayon swabs were the least efficient method. However, further studies are required in health care settings.
- 1 September 2014
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 52 (9) , 3426-3428
Open AccessDetecting Clostridium difficile Spores from Inanimate Surfaces of the Hospital Environment: Which Method Is Best?
The recovery of Clostridium difficile spores from hospital surfaces was assessed using rayon swabs, flocked swabs, and contact plates. The contact plate method was less laborious, achieved higher recovery percentages, and detected spores at lower inocula than swabs. Rayon swabs were the least efficient method. However, further studies are required in health care settings.
- 1 July 2014
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 35 (7) , 869-871
What Is the Best Method? Recovery of Methicillin-Resistant Staphylococcus aureus and Extended-Spectrum β-Lactamase–Producing Escherichia coli from Inanimate Hospital Surfaces
Environmental sampling in hospitals, when required, needs to be reliable. We evaluated different methods of sampling methicillin-resistant Staphylococcus aureus and extended-spectrum β-lactamase–producing Escherichia coli on 5 materials of the hospital setting. Petrifilms and contact plates were superior to swabs for all of the surfaces studied.Infect Control Hosp Epidemiol 2014;35(7):869–871
- 1 July 2014
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 35 (7) , 869-871
What Is the Best Method? Recovery of Methicillin-Resistant Staphylococcus aureus and Extended-Spectrum β-Lactamase–Producing Escherichia coli from Inanimate Hospital Surfaces
Environmental sampling in hospitals, when required, needs to be reliable. We evaluated different methods of sampling methicillin-resistant Staphylococcus aureus and extended-spectrum β-lactamase–producing Escherichia coli on 5 materials of the hospital setting. Petrifilms and contact plates were superior to swabs for all of the surfaces studied.Infect Control Hosp Epidemiol 2014;35(7):869–871