Jian Shan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jian Shan has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Xiyu Yang
University of South China
7 shared publicationsHui Yang
Key Laboratory of Advanced Nuclear Energy Design and Safety, Ministry of Education, Hunan Key Laboratory of Radon, School of Nuclear Science and Technology, University of South China, Hengyang, China
6 shared publicationsFengdi Qin
China Institute of Atomic Energy, Beijing, China
5 shared publicationsHaoxuan Li
School of Nuclear Science and Technology, University of South China, Hunan , China
4 shared publicationsHongliang Li
Key Laboratory of Advanced Nuclear Energy Design and Safety, Ministry of Education, Hunan Key Laboratory of Radon, School of Nuclear Science and Technology, University of South China, Hengyang, China
4 shared publications- Hui Yang
School of Nuclear Science and Technology, University of South China, Hengyang, CHINA
4 shared publications
Latest Publications
- 24 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (10) , 196
Novel wavelet threshold multi-point method for smoothing low-count gamma spectra
- 24 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (10) , 196
Novel wavelet threshold multi-point method for smoothing low-count gamma spectra
- Open Access
- 14 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (14) , 3097
Integrated Compensation System Based on YNVD Balanced Transformer and Supercapacitor Energy Storage
High-speed railway traction power supply systems suffer from power quality issues, including negative sequence, harmonics, and reactive power, as well as low utilization of regenerative braking energy. To address these issues, this paper proposes a collaborative control scheme based on YNVD balanced transformer, railway power conditioner (RPC), and supercapacitor (SC) energy storage. The YNVD transformer serves as the main circuit, the RPC performs power quality compensation and enables energy interaction, and the SC connects to the DC side of the RPC via a bidirectional DC/DC converter. Based on the analysis of the power supply characteristics and RPC compensation mechanism, a multi-condition adaptive energy management strategy is formulated to improve both power quality and regenerative braking energy efficiency. The system operates in five modes to realize adaptive condition matching. A hysteresis control strategy for RPC converters and a current closed-loop cooperative control strategy for DC/DC converters are designed. Matlab/Simulink simulation results verify that the proposed scheme effectively suppresses grid-side negative sequence and harmonic current components, significantly improves power quality, and realizes efficient storage and release of regenerative braking energy, providing a feasible solution for the performance optimization of electrified railway traction power supply systems.
- 14 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (14) , 3097
Open AccessIntegrated Compensation System Based on YNVD Balanced Transformer and Supercapacitor Energy Storage
High-speed railway traction power supply systems suffer from power quality issues, including negative sequence, harmonics, and reactive power, as well as low utilization of regenerative braking energy. To address these issues, this paper proposes a collaborative control scheme based on YNVD balanced transformer, railway power conditioner (RPC), and supercapacitor (SC) energy storage. The YNVD transformer serves as the main circuit, the RPC performs power quality compensation and enables energy interaction, and the SC connects to the DC side of the RPC via a bidirectional DC/DC converter. Based on the analysis of the power supply characteristics and RPC compensation mechanism, a multi-condition adaptive energy management strategy is formulated to improve both power quality and regenerative braking energy efficiency. The system operates in five modes to realize adaptive condition matching. A hysteresis control strategy for RPC converters and a current closed-loop cooperative control strategy for DC/DC converters are designed. Matlab/Simulink simulation results verify that the proposed scheme effectively suppresses grid-side negative sequence and harmonic current components, significantly improves power quality, and realizes efficient storage and release of regenerative braking energy, providing a feasible solution for the performance optimization of electrified railway traction power supply systems.
- 16 June 2026
- Published by Elsevier in Radiation Measurements
- Vol. 197
Parallel online measurement of the activity size distribution of radon progeny aerosols
- 16 June 2026
- Published by Elsevier in Radiation Measurements
- Vol. 197
Parallel online measurement of the activity size distribution of radon progeny aerosols
- 23 April 2026
- Published by Springer Nature in Analytical Sciences
- Vol. 42 (6) , 461-478
Research on peak shift probability method based on laser-induced plasma spectroscopy
The rapid and reliable in-situ detection of trace elements relevant to nuclear materials and metal elements in environmental matrices is a major challenge in the fields of environmental monitoring, nuclear safety, and resource assessment. Element identification in Laser-induced Plasma Spectroscopy (LIPS, synonymous with Laser-induced Breakdown Spectroscopy or LIBS) can be achieved by analyzing the corresponding peak information emitted by the plasma. However, due to differences in spectral databases (e.g., wavelength shift), making quick judgments remains challenging. To tackle this issue, we developed a novel data analysis strategy that explicitly accounts for spectral peak shifts. This method was evaluated using both the Akaike and Bayesian Information Criteria (AIC/ BIC) and correlation coefficients to enhance the reliability of LIPS for aerosol analysis. This approach statistically models inevitable spectral peak shifts to establish a probabilistic identification framework, offering clear evaluative criteria for detecting key elements in complex environmental samples. Experimental results demonstrate that this method substantially lowers misidentification risks and offers a robust analytical tool for field deployment and real-time environmental screening. Graphical abstract The alternative text for this image may have been generated using AI.
- 23 April 2026
- Published by Springer Nature in Analytical Sciences
- Vol. 42 (6) , 461-478
Research on peak shift probability method based on laser-induced plasma spectroscopy
The rapid and reliable in-situ detection of trace elements relevant to nuclear materials and metal elements in environmental matrices is a major challenge in the fields of environmental monitoring, nuclear safety, and resource assessment. Element identification in Laser-induced Plasma Spectroscopy (LIPS, synonymous with Laser-induced Breakdown Spectroscopy or LIBS) can be achieved by analyzing the corresponding peak information emitted by the plasma. However, due to differences in spectral databases (e.g., wavelength shift), making quick judgments remains challenging. To tackle this issue, we developed a novel data analysis strategy that explicitly accounts for spectral peak shifts. This method was evaluated using both the Akaike and Bayesian Information Criteria (AIC/ BIC) and correlation coefficients to enhance the reliability of LIPS for aerosol analysis. This approach statistically models inevitable spectral peak shifts to establish a probabilistic identification framework, offering clear evaluative criteria for detecting key elements in complex environmental samples. Experimental results demonstrate that this method substantially lowers misidentification risks and offers a robust analytical tool for field deployment and real-time environmental screening. Graphical abstract The alternative text for this image may have been generated using AI.
- 6 March 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (9) , 2795-2808
Denoising method based on an improved discrete wavelet transform
Laser-induced breakdown spectroscopy (LIBS) is susceptible to interference from factors such as ambient light, detector noise, and bremsstrahlung radiation, which can compromise the accurate identification of weak signals and reduce analytical accuracy. To mitigate the impact of noise, this study proposes a criterion for determining the optimal decomposition level of discrete wavelet transform (DWT) based on wavelet transform, Nyquist sampling rate, and entropy theory. A novel thresholding function, to our knowledge, and a threshold correction model, which is dependent on the decomposition level (DL), are developed. Denoising experiments were performed on the measured weak signal spectra of sulfur-containing aerosols. The results demonstrate that, compared to traditional soft and hard thresholding methods, the use of the proposed thresholding function yields a maximum improvement in signal-to-noise ratio (SNR) by 77%, while the root-mean-square error (RMSE) has been reduced by up to 55%. After applying this method, the limit of detection (LOD), mean average error (MAE), and linear correlation coefficient (R 2 ) of the spectral calibration curves were all improved compared with those obtained from the original spectra. This study provides effective technical support for the denoising of LIBS spectra.
- 6 March 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (9) , 2795-2808
Denoising method based on an improved discrete wavelet transform
Laser-induced breakdown spectroscopy (LIBS) is susceptible to interference from factors such as ambient light, detector noise, and bremsstrahlung radiation, which can compromise the accurate identification of weak signals and reduce analytical accuracy. To mitigate the impact of noise, this study proposes a criterion for determining the optimal decomposition level of discrete wavelet transform (DWT) based on wavelet transform, Nyquist sampling rate, and entropy theory. A novel thresholding function, to our knowledge, and a threshold correction model, which is dependent on the decomposition level (DL), are developed. Denoising experiments were performed on the measured weak signal spectra of sulfur-containing aerosols. The results demonstrate that, compared to traditional soft and hard thresholding methods, the use of the proposed thresholding function yields a maximum improvement in signal-to-noise ratio (SNR) by 77%, while the root-mean-square error (RMSE) has been reduced by up to 55%. After applying this method, the limit of detection (LOD), mean average error (MAE), and linear correlation coefficient (R 2 ) of the spectral calibration curves were all improved compared with those obtained from the original spectra. This study provides effective technical support for the denoising of LIBS spectra.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
Multiscale Background Subtraction and Deconvolution Method for Weak-Peak Gamma Spectrum under Low Peak-to-Compton Ratios
Although LaBr₃(Ce) detectors offer high detection efficiency for rapid in-situ measurement of low- and intermediate-level radioactive waste (LILW), their low energy resolution compromises the accuracy of conventional spectrum analysis methods, often resulting in the loss of weak peak information. To address this challenge, this research develops an adaptive Statistics-sensitive Nonlinear Iterative Peak-clipping (SNIP) parameter model, a multiscale Discrete Wavelet Transform (DWT)-based background correction model and a novel Skew-Normal distribution response function, and further proposes the multiscale WT-SNIP background subtraction and SN-ACTIVE deconvolution methods. Experimental and simulation results demonstrate that the WT-SNIP method accurately distinguishes peak and non-peak regions under low peak-to-Compton ratios (P/C) and adaptively performs effective background subtraction, yielding an average relative error of only 3.65% in net peak area, a 77.31% reduction compared with traditional SNIP, Gamma Vision and polynomial fitting. For overlapping peaks with area ratios of 1:1 to 1:10, WT-SNIP improved the peak-to-valley ratio (P/V) by 1.71–19.88 times, markedly surpassing the 1.03–1.60 times achieved by conventional methods. Furthermore, after precise background subtraction by WT-SNIP, SN-ACTIVE deconvolutes the broadened spectrum into an ideal incident spectrum, enabling more accurate weak peak search and area calculation, reducing errors by 30.00% and 75.98%, respectively, compared with the Gold algorithm, while improving convergence by three orders of magnitude. By integrating the proposed methods, adaptive multiscale background subtraction and spectrum deconvolution are achieved under low energy resolution, thereby enhancing the accuracy and robustness of qualitative and quantitative analyses in complex gamma spectrum. This research offers solid theoretical and technical support for the application of LaBr₃(Ce) detectors in rapid in-situ LILW measurements.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
Multiscale Background Subtraction and Deconvolution Method for Weak-Peak Gamma Spectrum under Low Peak-to-Compton Ratios
Although LaBr₃(Ce) detectors offer high detection efficiency for rapid in-situ measurement of low- and intermediate-level radioactive waste (LILW), their low energy resolution compromises the accuracy of conventional spectrum analysis methods, often resulting in the loss of weak peak information. To address this challenge, this research develops an adaptive Statistics-sensitive Nonlinear Iterative Peak-clipping (SNIP) parameter model, a multiscale Discrete Wavelet Transform (DWT)-based background correction model and a novel Skew-Normal distribution response function, and further proposes the multiscale WT-SNIP background subtraction and SN-ACTIVE deconvolution methods. Experimental and simulation results demonstrate that the WT-SNIP method accurately distinguishes peak and non-peak regions under low peak-to-Compton ratios (P/C) and adaptively performs effective background subtraction, yielding an average relative error of only 3.65% in net peak area, a 77.31% reduction compared with traditional SNIP, Gamma Vision and polynomial fitting. For overlapping peaks with area ratios of 1:1 to 1:10, WT-SNIP improved the peak-to-valley ratio (P/V) by 1.71–19.88 times, markedly surpassing the 1.03–1.60 times achieved by conventional methods. Furthermore, after precise background subtraction by WT-SNIP, SN-ACTIVE deconvolutes the broadened spectrum into an ideal incident spectrum, enabling more accurate weak peak search and area calculation, reducing errors by 30.00% and 75.98%, respectively, compared with the Gold algorithm, while improving convergence by three orders of magnitude. By integrating the proposed methods, adaptive multiscale background subtraction and spectrum deconvolution are achieved under low energy resolution, thereby enhancing the accuracy and robustness of qualitative and quantitative analyses in complex gamma spectrum. This research offers solid theoretical and technical support for the application of LaBr₃(Ce) detectors in rapid in-situ LILW measurements.
- Open Access
- 15 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 13168
Methodological Applicability of Ultra-Low Background Liquid Scintillation Counters in Low-Level Tritium Measurement
Tritium (3H) is a low-energy β emitter commonly found in environmental water samples, and its routine monitoring requires highly sensitive techniques capable of achieving low detection limits. Liquid scintillation counting (LSC) is the standard method for low-level 3H analysis; however, quenching significantly affects detection efficiency and minimum detectable activity (MDA), and systematic evaluations across different quench levels and measurement approaches remain limited. This study evaluates quench-related uncertainties in low-level 3H measurement using two ultra-low background liquid scintillation counters, Quantulus 1220 and GCT 6220. High- and low-quench conditions were created by varying sample-to-cocktail ratios, and performance was assessed through detection efficiency, minimum detectable activity (MDA), and stability. Under the relative measurement method with limited quench variation, GCT 6220 achieved higher efficiency, lower background, and lower detection limits. Under the internal standard method with broader quench spans, Quantulus 1220 produced smoother efficiency–quench curves and more stable results. Thus, GCT 6220 is advantageous for sensitivity-demanding scenarios, while Quantulus 1220 is better suited for quench-correction applications.
- 15 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 13168
Open AccessMethodological Applicability of Ultra-Low Background Liquid Scintillation Counters in Low-Level Tritium Measurement
Tritium (3H) is a low-energy β emitter commonly found in environmental water samples, and its routine monitoring requires highly sensitive techniques capable of achieving low detection limits. Liquid scintillation counting (LSC) is the standard method for low-level 3H analysis; however, quenching significantly affects detection efficiency and minimum detectable activity (MDA), and systematic evaluations across different quench levels and measurement approaches remain limited. This study evaluates quench-related uncertainties in low-level 3H measurement using two ultra-low background liquid scintillation counters, Quantulus 1220 and GCT 6220. High- and low-quench conditions were created by varying sample-to-cocktail ratios, and performance was assessed through detection efficiency, minimum detectable activity (MDA), and stability. Under the relative measurement method with limited quench variation, GCT 6220 achieved higher efficiency, lower background, and lower detection limits. Under the internal standard method with broader quench spans, Quantulus 1220 produced smoother efficiency–quench curves and more stable results. Thus, GCT 6220 is advantageous for sensitivity-demanding scenarios, while Quantulus 1220 is better suited for quench-correction applications.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3210-3225
A Novel Adaptive-Scale Continuous Wavelet Transform Method for Weak Peak Search in Low-Resolution Gamma Spectrum
During measurements of Low- and Intermediate-Level Radioactive Waste (LILW), multiple factors can result in a significant number of weak peaks being partially or entirely obscured in the gamma spectrum. This phenomenon complicates accurate nuclide identification. To leverage the high detection efficiency of the LaBr3(Ce) detector for the on-site LILW measurements, research has been conducted to address the challenge posed by its low energy resolution, which hinders the precise search of weak peaks. A novel Continuous Wavelet Transform (CWT) weak peak search method has been proposed based on the analysis of CWT characteristics of gamma spectrum with different low signal-to-noise ratios (SNRs). The proposed method introduces a non-uniform scale parameter model for the mother wavelet, enabling adaptive adjustment based on energy resolution. Compared to conventional CWT, this approach significantly reduces energy error in peak search, with a maximum decrease of 97.9%. Furthermore, it improves multiplet peak resolution by 52.3%. Applying this method to peak search in gamma spectrum of nuclides (Cs-137, Co-60, Ba-133 and Eu-152) in LILW. The results show an absolute energy error of less than 1.5 keV, with an uncertainty of about 1 keV. Compared to Gamma Vision software, this method reduces absolute energy error by 95.15% and uncertainty by 91.95% in weak peak search. Compared with the traditional CWT, symmetric zero-area, covariance and Fourier transform methods, the proposed approach exhibits superior peak search performance on low-resolution complex spectrum, achieving true positive rate (TPR) improvements of up to 0.77 and false discovery rate (FDR) reductions of up to 0.85. This research provides a theoretical foundation and essential technical support for the application of LaBr3(Ce) in the field of LILW measurement.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3210-3225
A Novel Adaptive-Scale Continuous Wavelet Transform Method for Weak Peak Search in Low-Resolution Gamma Spectrum
During measurements of Low- and Intermediate-Level Radioactive Waste (LILW), multiple factors can result in a significant number of weak peaks being partially or entirely obscured in the gamma spectrum. This phenomenon complicates accurate nuclide identification. To leverage the high detection efficiency of the LaBr3(Ce) detector for the on-site LILW measurements, research has been conducted to address the challenge posed by its low energy resolution, which hinders the precise search of weak peaks. A novel Continuous Wavelet Transform (CWT) weak peak search method has been proposed based on the analysis of CWT characteristics of gamma spectrum with different low signal-to-noise ratios (SNRs). The proposed method introduces a non-uniform scale parameter model for the mother wavelet, enabling adaptive adjustment based on energy resolution. Compared to conventional CWT, this approach significantly reduces energy error in peak search, with a maximum decrease of 97.9%. Furthermore, it improves multiplet peak resolution by 52.3%. Applying this method to peak search in gamma spectrum of nuclides (Cs-137, Co-60, Ba-133 and Eu-152) in LILW. The results show an absolute energy error of less than 1.5 keV, with an uncertainty of about 1 keV. Compared to Gamma Vision software, this method reduces absolute energy error by 95.15% and uncertainty by 91.95% in weak peak search. Compared with the traditional CWT, symmetric zero-area, covariance and Fourier transform methods, the proposed approach exhibits superior peak search performance on low-resolution complex spectrum, achieving true positive rate (TPR) improvements of up to 0.77 and false discovery rate (FDR) reductions of up to 0.85. This research provides a theoretical foundation and essential technical support for the application of LaBr3(Ce) in the field of LILW measurement.
- 21 February 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (4) , 2809-2821
Optimized mix proportion design for radiation-shielding concrete using particle swarm optimization: a case study on fast neutron and gamma shielding
- 21 February 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (4) , 2809-2821
Optimized mix proportion design for radiation-shielding concrete using particle swarm optimization: a case study on fast neutron and gamma shielding
- Open Access
- 14 January 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (2) , 1
Correction: A novel method for simultaneous measurement of 222Rn and 220Rn progeny concentrations measured by an alpha spectrometer
- 14 January 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (2) , 1
Open AccessCorrection: A novel method for simultaneous measurement of 222Rn and 220Rn progeny concentrations measured by an alpha spectrometer