Huadong Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Huadong Cheng has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Ling Xiao
Wangzhijiang Innovation Center for Laser, Aerospace Laser Technology and System Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
17 shared publications- Liang Liu
Aerospace Laser Technology and System Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
15 shared publications - Jianliao Deng
Shanghai Institute of Optics and Fine Mechanics
7 shared publications - Bowen Yang
Wangzhijiang Innovation Center for Laser, Aerospace Laser Technology and System Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, People’s Republic of China
6 shared publications Jin-Yin Wan
Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Key Lab Quantum Opt, Shanghai 201800, Peoples R China
6 shared publicationsJinyin Wan
Key Laboratory of Quantum Optics and Center of Cold Atom Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
6 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Optics
- Vol. 28 (1) , 015201
Compact fiber-free-space optical system for an integrating sphere cold atom clock
We present a miniaturized, fiber-free-space hybrid optical system designed for a spaceborne integrating sphere cold-atom clock (ISCAC). All optical components were integrated on both sides of a 20% SiC/Al composite bench, with dimensions of 220 × 220 × 65.5 mm, achieving remarkable compactness (3.17 L volume) and lightweight characteristics (2.6 kg mass). The laser source was split into six functional beams for cooling, probing, pumping, repumping, and two dedicated beams for modulation transfer spectroscopy. Comprehensive opto-mechanical-thermal co-simulations and experimental validation demonstrate robustness of the system under 10.26 g RMS mechanical vibrations, simulating satellite launch conditions, with output power variations maintained below 2%. Furthermore, the system exhibited high thermal stability during temperature cycling (−5 ∘ C to 45 ∘ C), with fiber coupling efficiency variations constrained within 1% across all laser paths. Following power stabilization, the contribution of detection light relative intensity noise to ISCAC stability improved from 1.59 × 10 − 12 τ − 1 / 2 to 1.04 × 10 − 14 τ − 1 / 2 . After frequency locking, the impact of laser frequency noise on frequency stability was reduced to 7.89 × 10 − 15 τ − 1 / 2 . These results demonstrate that the laser system meets the stringent requirements for spaceborne cold atomic clocks.
- 1 January 2026
- Published by IOP Publishing in Journal of Optics
- Vol. 28 (1) , 015201
Open AccessCompact fiber-free-space optical system for an integrating sphere cold atom clock
We present a miniaturized, fiber-free-space hybrid optical system designed for a spaceborne integrating sphere cold-atom clock (ISCAC). All optical components were integrated on both sides of a 20% SiC/Al composite bench, with dimensions of 220 × 220 × 65.5 mm, achieving remarkable compactness (3.17 L volume) and lightweight characteristics (2.6 kg mass). The laser source was split into six functional beams for cooling, probing, pumping, repumping, and two dedicated beams for modulation transfer spectroscopy. Comprehensive opto-mechanical-thermal co-simulations and experimental validation demonstrate robustness of the system under 10.26 g RMS mechanical vibrations, simulating satellite launch conditions, with output power variations maintained below 2%. Furthermore, the system exhibited high thermal stability during temperature cycling (−5 ∘ C to 45 ∘ C), with fiber coupling efficiency variations constrained within 1% across all laser paths. Following power stabilization, the contribution of detection light relative intensity noise to ISCAC stability improved from 1.59 × 10 − 12 τ − 1 / 2 to 1.04 × 10 − 14 τ − 1 / 2 . After frequency locking, the impact of laser frequency noise on frequency stability was reduced to 7.89 × 10 − 15 τ − 1 / 2 . These results demonstrate that the laser system meets the stringent requirements for spaceborne cold atomic clocks.
- 24 November 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (5)
Rabi pulling effect in a compact cold-atom clock
- 24 November 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (5)
Rabi pulling effect in a compact cold-atom clock
- Open Access
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
High-performance laser system for compact cold-atom optical clock
We demonstrate a straightforward frequency-locking technique that employs external modulation saturation absorption spectroscopy to achieve a high-performance 780 nm laser system. By externally modulating the laser frequency through a fiber electro-optic modulator, this scheme can stabilize multiple transitions of the 87Rb D2 line with excellent performance. Experimental results establish fractional frequency instability of 2.21 × 10−13 at 1 s with a linewidth of 1.46 kHz for the cycling transition 5S1/2(Fg = 2) → 5P3/2(Fe = 3). Notably, we have locked the system to the repumping transition 5S1/2(Fg = 1) → 5P3/2(Fe = 2), achieving a record-low instability of 1.98 × 10−12 at 1 s averaging time. This simplified laser system, featuring exceptional short-term frequency stability and multi-frequency locking capability, serves as a critical subsystem for the compact cold-atom optical clock, enabling advanced precision metrology applications. Furthermore, its metrological performance enables immediate applications in other quantum sensors, such as Rydberg electrometry, atomic magnetometry, and matter-wave interferometry.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Open AccessHigh-performance laser system for compact cold-atom optical clock
We demonstrate a straightforward frequency-locking technique that employs external modulation saturation absorption spectroscopy to achieve a high-performance 780 nm laser system. By externally modulating the laser frequency through a fiber electro-optic modulator, this scheme can stabilize multiple transitions of the 87Rb D2 line with excellent performance. Experimental results establish fractional frequency instability of 2.21 × 10−13 at 1 s with a linewidth of 1.46 kHz for the cycling transition 5S1/2(Fg = 2) → 5P3/2(Fe = 3). Notably, we have locked the system to the repumping transition 5S1/2(Fg = 1) → 5P3/2(Fe = 2), achieving a record-low instability of 1.98 × 10−12 at 1 s averaging time. This simplified laser system, featuring exceptional short-term frequency stability and multi-frequency locking capability, serves as a critical subsystem for the compact cold-atom optical clock, enabling advanced precision metrology applications. Furthermore, its metrological performance enables immediate applications in other quantum sensors, such as Rydberg electrometry, atomic magnetometry, and matter-wave interferometry.
- 25 September 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (3)
Laser-noise-immune pulsed optically pumped atomic clock by means of differential detection
- 25 September 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (3)
Laser-noise-immune pulsed optically pumped atomic clock by means of differential detection
- 11 March 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (3) , 032609
Sensitivity of Rydberg microwave electrometry limited by laser frequency noise
Laser frequency or phase noise is a main factor that limits the sensitivity of Rydberg microwave (MW) electrometry. In this study, we proposed a theoretical approach to estimate the effect of laser frequency noise on the atomic coherence of Rydberg sensors based on an atomic superheterodyne receiver. The noisy lasers were characterized using a phase-diffusion model. In particular, explicit formulas were derived to evaluate the noise-limited sensitivity for a given laser linewidth. Furthermore, the effect of Doppler broadening on the sensitivity of the Rydberg sensor at different atomic temperatures was estimated. Our theoretical results provide guidance for the development of Rydberg MW sensors and the method discussed herein can be applied to many other quantum systems.
- 11 March 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (3) , 032609
Sensitivity of Rydberg microwave electrometry limited by laser frequency noise
Laser frequency or phase noise is a main factor that limits the sensitivity of Rydberg microwave (MW) electrometry. In this study, we proposed a theoretical approach to estimate the effect of laser frequency noise on the atomic coherence of Rydberg sensors based on an atomic superheterodyne receiver. The noisy lasers were characterized using a phase-diffusion model. In particular, explicit formulas were derived to evaluate the noise-limited sensitivity for a given laser linewidth. Furthermore, the effect of Doppler broadening on the sensitivity of the Rydberg sensor at different atomic temperatures was estimated. Our theoretical results provide guidance for the development of Rydberg MW sensors and the method discussed herein can be applied to many other quantum systems.
- 6 March 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (3) , L031003
Highly sensitive microwave electrometry with enhanced instantaneous bandwidth
Rydberg microwave (MW) sensors are superior to conventional antenna-based techniques because of their wide operating frequency range and outstanding potential sensitivity. Here, we demonstrate a Rydberg microwave receiver with a high sensitivity of and broad instantaneous bandwidth of up to . Such excellent performance was achieved by the amplification of one generated sideband wave induced by the strong coupling field in the six-wave mixing process of the Rydberg superheterodyne receiver, which was well predicted by our theory. Our system, which possesses a uniquely enhanced instantaneous bandwidth and high-sensitivity features that can be improved further, will promote the application of Rydberg microwave electrometry in radar and communication.- 6 March 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (3) , L031003
Highly sensitive microwave electrometry with enhanced instantaneous bandwidth
Rydberg microwave (MW) sensors are superior to conventional antenna-based techniques because of their wide operating frequency range and outstanding potential sensitivity. Here, we demonstrate a Rydberg microwave receiver with a high sensitivity of and broad instantaneous bandwidth of up to . Such excellent performance was achieved by the amplification of one generated sideband wave induced by the strong coupling field in the six-wave mixing process of the Rydberg superheterodyne receiver, which was well predicted by our theory. Our system, which possesses a uniquely enhanced instantaneous bandwidth and high-sensitivity features that can be improved further, will promote the application of Rydberg microwave electrometry in radar and communication.- Open Access
High-Sensitive Microwave Electrometry with Enhanced Instantaneous Bandwidth
Rydberg microwave (MW) sensors are superior to conventional antenna-based techniques because of their wide operating frequency range and outstanding potential sensitivity. Here, we demonstrate a Rydberg microwave receiver with a high sensitivity of $62\,\mathrm{nV} \mathrm{cm}^{-1} \mathrm{Hz}^{-1/2}$ and broad instantaneous bandwidth of up to $10.2\,\mathrm{MHz}$. Such excellent performance was achieved by the amplification of one generated sideband wave induced by the strong coupling field in the six-wave mixing process of the Rydberg superheterodyne receiver, which was well predicted by our theory. Our system, which possesses a uniquely enhanced instantaneous bandwidth and high-sensitivity features that can be improved further, will promote the application of Rydberg microwave electrometry in radar and communication.Open AccessHigh-Sensitive Microwave Electrometry with Enhanced Instantaneous Bandwidth
Rydberg microwave (MW) sensors are superior to conventional antenna-based techniques because of their wide operating frequency range and outstanding potential sensitivity. Here, we demonstrate a Rydberg microwave receiver with a high sensitivity of $62\,\mathrm{nV} \mathrm{cm}^{-1} \mathrm{Hz}^{-1/2}$ and broad instantaneous bandwidth of up to $10.2\,\mathrm{MHz}$. Such excellent performance was achieved by the amplification of one generated sideband wave induced by the strong coupling field in the six-wave mixing process of the Rydberg superheterodyne receiver, which was well predicted by our theory. Our system, which possesses a uniquely enhanced instantaneous bandwidth and high-sensitivity features that can be improved further, will promote the application of Rydberg microwave electrometry in radar and communication. - 14 October 2022
- Published by Taylor & Francis
- p. 482-492
Stress analysis of the cable tower during hoisting construction of a self-ascending crane of the Shunde Bridge
The common form of cable tower of the cable-stayed bridge is an H-shaped cable tower. Because the transverse direction of the bridge forms a certain included angle with the vertical plane, the stress of the cable tower is relatively large under the action of self-weight. In addition, the section and beam are hoisted by the climbing crane, which makes the cable tower in a more unfavorable working condition. Therefore, the 1/2 symmetrical model of the cable tower is established by using ABAQUS (a large commercial general finite element software), According to 9 kinds of adverse working conditions in construction, the corresponding boundary conditions are established and the corresponding loads are applied, and the cable tower stress under each adverse working condition is calculated. The results show that the maximum mise stress of the steel plate under various working conditions is 35.2Mpa, which meets the requirements of the specification. The maximum principal tensile stress of concrete is 2.5 MPa, which meets the specification requirements. The maximum principal compressive stress is 12.7 MPa, meeting the specification requirements. Three conclusions are further summarized: (1) most of the maximum stress of the steel plate in the construction process occurs at the bottom of the lower beam of the composite tower; (2) During the hoisting of the composite tower, the maximum tensile stress of concrete appears at the anchorage between a crane and cable tower, while during the hoisting of a steel tower, the maximum tensile stress of concrete appears at the steel-concrete joint section; (3) During hoisting, the maximum stress of the steel plate at the anchorage between the crane and the tower wall shall not exceed 20MPa, which mainly occurs when hoisting the section of the composite tower. At the same time, the corresponding reasons are analyzed to provide strong support for the optimization of the construction scheme.
- 14 October 2022
- Published by Taylor & Francis
- p. 482-492
Stress analysis of the cable tower during hoisting construction of a self-ascending crane of the Shunde Bridge
The common form of cable tower of the cable-stayed bridge is an H-shaped cable tower. Because the transverse direction of the bridge forms a certain included angle with the vertical plane, the stress of the cable tower is relatively large under the action of self-weight. In addition, the section and beam are hoisted by the climbing crane, which makes the cable tower in a more unfavorable working condition. Therefore, the 1/2 symmetrical model of the cable tower is established by using ABAQUS (a large commercial general finite element software), According to 9 kinds of adverse working conditions in construction, the corresponding boundary conditions are established and the corresponding loads are applied, and the cable tower stress under each adverse working condition is calculated. The results show that the maximum mise stress of the steel plate under various working conditions is 35.2Mpa, which meets the requirements of the specification. The maximum principal tensile stress of concrete is 2.5 MPa, which meets the specification requirements. The maximum principal compressive stress is 12.7 MPa, meeting the specification requirements. Three conclusions are further summarized: (1) most of the maximum stress of the steel plate in the construction process occurs at the bottom of the lower beam of the composite tower; (2) During the hoisting of the composite tower, the maximum tensile stress of concrete appears at the anchorage between a crane and cable tower, while during the hoisting of a steel tower, the maximum tensile stress of concrete appears at the steel-concrete joint section; (3) During hoisting, the maximum stress of the steel plate at the anchorage between the crane and the tower wall shall not exceed 20MPa, which mainly occurs when hoisting the section of the composite tower. At the same time, the corresponding reasons are analyzed to provide strong support for the optimization of the construction scheme.
- 1 July 2021
- Published by IOP Publishing in Chinese Physics B
- Vol. 30 (8) , 083202
An effective pumping method for increasing atomic utilization in a compact cold atom clock*
We propose a simple pumping method to increase the effective population of cold atoms in the clock state and investigate the factors which affect the pumping efficiency in cold atom systems. We report the theory and demonstrate the corresponding experiment in an 87Rb integrating sphere cold atom clock. The experimental results show that the population of cold atoms in the Zeeman sublevel |F = 2, mF = 0〉 is approximately 1.62 times that of the result using optical pumping alone. This method can also be applied to increase the effective population in any one of the target Zeeman sublevels in other cold atom systems.
- 1 July 2021
- Published by IOP Publishing in Chinese Physics B
- Vol. 30 (8) , 083202
An effective pumping method for increasing atomic utilization in a compact cold atom clock*
We propose a simple pumping method to increase the effective population of cold atoms in the clock state and investigate the factors which affect the pumping efficiency in cold atom systems. We report the theory and demonstrate the corresponding experiment in an 87Rb integrating sphere cold atom clock. The experimental results show that the population of cold atoms in the Zeeman sublevel |F = 2, mF = 0〉 is approximately 1.62 times that of the result using optical pumping alone. This method can also be applied to increase the effective population in any one of the target Zeeman sublevels in other cold atom systems.
- 26 April 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 103 (4) , 043118
Distortion of Rabi oscillations in a compact cold-atom clock
We report on experimental measurements and theoretical calculations of Rabi oscillation distortion during rubidium clock transition in a compact cold-atom clock. The distortion of the Rabi oscillations of the clock transition caused by the magnetically sensitive transitions between magnetic sublevels is related to the duration and amplitude of the microwave pulse, the density distribution of cold atoms, and the biased magnetic field inside the microwave cavity. The theoretical calculations agreed well with the experimental results. The Rabi oscillation measurements are beneficial for determining the optimal parameters of a cold-atom clock and identifying the uniformity of the microwave field inside the cavity. This measurement can be extended to the atomic fountain clock and the vapor-cell atomic clock.
- 26 April 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 103 (4) , 043118
Distortion of Rabi oscillations in a compact cold-atom clock
We report on experimental measurements and theoretical calculations of Rabi oscillation distortion during rubidium clock transition in a compact cold-atom clock. The distortion of the Rabi oscillations of the clock transition caused by the magnetically sensitive transitions between magnetic sublevels is related to the duration and amplitude of the microwave pulse, the density distribution of cold atoms, and the biased magnetic field inside the microwave cavity. The theoretical calculations agreed well with the experimental results. The Rabi oscillation measurements are beneficial for determining the optimal parameters of a cold-atom clock and identifying the uniformity of the microwave field inside the cavity. This measurement can be extended to the atomic fountain clock and the vapor-cell atomic clock.