Alfredo Vega Estrada
Research Subjects
Alfredo Vega Estrada has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jorge Luciano Alio
Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, Alicante, Spain
7 shared publications Jorge L. Alio
Department of Cornea and Refractive Surgery, Vissum, Alicante, Spain; Keratoconus Unit of Vissum, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
2 shared publications- Alessandro Abbouda
Vissum Corporacion Oftalmologica
1 shared publication - Ana B. Plaza-Puche
Vissum Grupo Miranza
1 shared publication Elias Espla
Department of Cornea and Refractive Surgery, VISSUM, Alicante, Spain
1 shared publication- Francisco Cavas
Technical University of Cartagena
1 shared publication
Latest Publications
- 26 September 2023
- Published by Springer Nature
- p. 127-137
Femtosecond-Assisted Penetrating Keratoplasty and Deep Anterior Lamellar Keratoplasty
- 26 September 2023
- Published by Springer Nature
- p. 127-137
Femtosecond-Assisted Penetrating Keratoplasty and Deep Anterior Lamellar Keratoplasty
- Open Access
- 30 January 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (2) , 82
Evidence of a Down Syndrome Keratopathy: A Three-Dimensional (3-D) Morphogeometric and Volumetric Analysis
The aim of this study was to investigate whether a different and abnormal corneal profile is present in Down syndrome (DS) by personalized three-dimensional (3D) modelling. This single-centre cross-sectional study included 43 patients with DS (43 eyes) and 58 age-sex-matched control subjects (58 eyes) with normal karyotype and topography. Refraction, central corneal thickness (CCT), aberrations (high-order, coma and spherical), asphericity and morphogeometric/volumetric parameters based on a 3D corneal model that was generated from raw topographical data were evaluated. Deviation of anterior/posterior apex (Dapexant/Dapexpost) and thinnest point (Dmctant/Dmctpost) from corneal vertex, anterior/posterior surface area (Aant/Apost), sagittal area passing through the anterior/posterior apex (Aapexant/Aapexpost) and thinnest point (Amctpost), total corneal volume (Vtotal) and volumetric progression for each 0.05 mm step of the radius value centred to the thinnest point (VOLMCT) and anterior/posterior apex (VOLAAP/VOLPAP) comprised the morphogeometric/volumetric parameters. In the DS group, 58.1% of the eyes presented abnormal topography. High-order and coma aberrations, asphericity, Dapexant, Aant, Apost and Aapexant were significantly higher, whereas CCT, Aapexpost, Amctpost, Vtotal, VOLAAP, VOLPAP and VOLMCT were lower in the DS group than in the control group (p < 0.05). Dapexpost did not differ between the groups (p > 0.05). This study demonstrates that corneas of the subjects with DS are different and more aberrated than those of normal age- and sex-matched non-DS controls. Anterior corneal apex appears to be displaced in DS even with normal topography, while posterior apex seems stable although topography is abnormal. These findings may help to modify our approach in the diagnosis of keratopathy in subjects with DS.
- 30 January 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (2) , 82
Open AccessEvidence of a Down Syndrome Keratopathy: A Three-Dimensional (3-D) Morphogeometric and Volumetric Analysis
The aim of this study was to investigate whether a different and abnormal corneal profile is present in Down syndrome (DS) by personalized three-dimensional (3D) modelling. This single-centre cross-sectional study included 43 patients with DS (43 eyes) and 58 age-sex-matched control subjects (58 eyes) with normal karyotype and topography. Refraction, central corneal thickness (CCT), aberrations (high-order, coma and spherical), asphericity and morphogeometric/volumetric parameters based on a 3D corneal model that was generated from raw topographical data were evaluated. Deviation of anterior/posterior apex (Dapexant/Dapexpost) and thinnest point (Dmctant/Dmctpost) from corneal vertex, anterior/posterior surface area (Aant/Apost), sagittal area passing through the anterior/posterior apex (Aapexant/Aapexpost) and thinnest point (Amctpost), total corneal volume (Vtotal) and volumetric progression for each 0.05 mm step of the radius value centred to the thinnest point (VOLMCT) and anterior/posterior apex (VOLAAP/VOLPAP) comprised the morphogeometric/volumetric parameters. In the DS group, 58.1% of the eyes presented abnormal topography. High-order and coma aberrations, asphericity, Dapexant, Aant, Apost and Aapexant were significantly higher, whereas CCT, Aapexpost, Amctpost, Vtotal, VOLAAP, VOLPAP and VOLMCT were lower in the DS group than in the control group (p < 0.05). Dapexpost did not differ between the groups (p > 0.05). This study demonstrates that corneas of the subjects with DS are different and more aberrated than those of normal age- and sex-matched non-DS controls. Anterior corneal apex appears to be displaced in DS even with normal topography, while posterior apex seems stable although topography is abnormal. These findings may help to modify our approach in the diagnosis of keratopathy in subjects with DS.
- 1 April 2019
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 200, 255-262
Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in Keratoconus
- 1 April 2019
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 200, 255-262
Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in Keratoconus
- 3 January 2018
- Published by Springer Nature
- p. 383-388
Management Complications of Intracorneal Ring Segment Implantation
- 3 January 2018
- Published by Springer Nature
- p. 383-388
Management Complications of Intracorneal Ring Segment Implantation
- 29 December 2016
- Published by Springer Nature
- p. 253-262
Carbon Nanomaterials: An Upcoming Therapy for Corneal Biomechanic Enhancement
- 29 December 2016
- Published by Springer Nature
- p. 253-262
Carbon Nanomaterials: An Upcoming Therapy for Corneal Biomechanic Enhancement
- 29 December 2016
- Published by Springer Nature
- p. 177-184
Keratoconus Grading and Its Therapeutic Implications
- 29 December 2016
- Published by Springer Nature
- p. 177-184
Keratoconus Grading and Its Therapeutic Implications
- Open Access
- 15 March 2016
- Published by Springer Nature in Eye and Vision
- Vol. 3 (1) , 1-7
The use of intracorneal ring segments in keratoconus
Keratoconus is a corneal degeneration that usually appears during puberty and may seriously deteriorate the quality of life of the patients. This corneal disease is today the first indication of corneal transplantation in young patients. Until the last decade of the XX century, keratoplasty procedures were the only alternative to treat this pathological condition. In the beginning of the XXI century, intracorneal ring segments implantation was proposed as a therapeutic choice for treating keratoconus patients. Since then, several published articles have reported the benefits of this surgical procedure in treating this type of corneal ectatic disorder. The purpose of the present investigative work is to summarize the characteristic of the intracorneal ring segments and also to review the different features published in the literature in relation to this surgical technique for the treatment of keratoconus patients.
- 15 March 2016
- Published by Springer Nature in Eye and Vision
- Vol. 3 (1) , 1-7
Open AccessThe use of intracorneal ring segments in keratoconus
Keratoconus is a corneal degeneration that usually appears during puberty and may seriously deteriorate the quality of life of the patients. This corneal disease is today the first indication of corneal transplantation in young patients. Until the last decade of the XX century, keratoplasty procedures were the only alternative to treat this pathological condition. In the beginning of the XXI century, intracorneal ring segments implantation was proposed as a therapeutic choice for treating keratoconus patients. Since then, several published articles have reported the benefits of this surgical procedure in treating this type of corneal ectatic disorder. The purpose of the present investigative work is to summarize the characteristic of the intracorneal ring segments and also to review the different features published in the literature in relation to this surgical technique for the treatment of keratoconus patients.
- Open Access
- 31 January 2015
- Published by Springer Nature in Eye and Vision
- Vol. 2 (1) , 1-9
Clinical outcomes with a new microincisional diffractive multifocal IOL
To evaluate the refractive outcomes and the optical performance as well as the quality of life in patients implanted with a new diffractive multifocal intraocular lens (IOL). Prospective, clinical study including 41 cases of patients who underwent cataract surgery and were divided in two groups: group 1, including 20 eyes implanted with the multifocal IOL SeeLens MF (Hanita Lenses, Israel); group 2, 21 eyes implanted with the Acrysof SA60AT IOL. Visual acuity, defocus curve, intraocular aberrations, contrast sensitivity function and quality of life were assessed during a follow up period of 6 months. Significant improvement was observed in the uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) in both groups (p < 0.02). The multifocal group showed better results in terms of uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (p < 0.01). Comparison of both groups showed better visual acuities for the multifocal IOL group in defocus levels from -3.0 D to -1.50 D (p ≤ 0.01). At 6 months, there was a significant reduction of the internal higher order aberrations (p ≤ 0.04). A significant increase in scotopic contrast sensitivity was detected for 6 cycles/° spatial frequency during follow up (p = 0.04), but no significant changes were observed for the rest of spatial frequencies (p ≥ 0.06). Visual Functioning Index (VF-14) questionnaire showed that patients reported high levels of satisfaction when performing daily tasks. The SeeLens MF IOL is able to successfully restore distance, near and intermediate visions after cataract surgery. It also provides functional intermediate vision with optimal intraocular optical quality.
- 31 January 2015
- Published by Springer Nature in Eye and Vision
- Vol. 2 (1) , 1-9
Open AccessClinical outcomes with a new microincisional diffractive multifocal IOL
To evaluate the refractive outcomes and the optical performance as well as the quality of life in patients implanted with a new diffractive multifocal intraocular lens (IOL). Prospective, clinical study including 41 cases of patients who underwent cataract surgery and were divided in two groups: group 1, including 20 eyes implanted with the multifocal IOL SeeLens MF (Hanita Lenses, Israel); group 2, 21 eyes implanted with the Acrysof SA60AT IOL. Visual acuity, defocus curve, intraocular aberrations, contrast sensitivity function and quality of life were assessed during a follow up period of 6 months. Significant improvement was observed in the uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) in both groups (p < 0.02). The multifocal group showed better results in terms of uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (p < 0.01). Comparison of both groups showed better visual acuities for the multifocal IOL group in defocus levels from -3.0 D to -1.50 D (p ≤ 0.01). At 6 months, there was a significant reduction of the internal higher order aberrations (p ≤ 0.04). A significant increase in scotopic contrast sensitivity was detected for 6 cycles/° spatial frequency during follow up (p = 0.04), but no significant changes were observed for the rest of spatial frequencies (p ≥ 0.06). Visual Functioning Index (VF-14) questionnaire showed that patients reported high levels of satisfaction when performing daily tasks. The SeeLens MF IOL is able to successfully restore distance, near and intermediate visions after cataract surgery. It also provides functional intermediate vision with optimal intraocular optical quality.
- 31 December 2014
- Published by Springer Nature
- p. 419-422
CXL in Pediatric Age
- 31 December 2014
- Published by Springer Nature
- p. 415-417
CXL and Delayed Wound Healing