Matthias Regling
Matthias Regling has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Arno Blau
Stryker Leibinger GmbH & Co. KG, Freiburg, Germany
1 shared publication Arthur de Gast
Stryker European Operations Ltd, Amsterdam, Netherlands
1 shared publicationBrendan M. Patterson
Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, IA, USA
1 shared publication- Brian D Solberg
Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
1 shared publication Gary F. Updegrove
Department of Orthopaedics and Rehabilitation, Penn State Hershey Bone and Joint Institute, Penn State Milton S. Hershey Medical Center, Hershey, USA
1 shared publication- James W Maxey
University of Illinois College of Medicine, Peoria, IL, USA
1 shared publication
Latest Publications
- Open Access
- 12 August 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1) , 685
Early surgeon experience with a fracture-specific humeral stem for proximal humerus fractures: a multicenter survey of predominantly reverse shoulder arthroplasty cases with an illustrative case
Background: Shoulder arthroplasty has become an established treatment option for displaced and complex proximal humeral fractures, particularly in elderly patients. Fracture-specific stems are increasingly used in clinical practice; however, early data on surgeon experience with newly introduced convertible stem designs remain limited. This study aimed to assess orthopedic surgeons’ early intraoperative experience with a newly developed humeral fracture system (Tornier Perform Humeral System – Fracture, Tornier Inc., a wholly owned subsidiary of Stryker, Bloomington, MN, USA) using a structured survey as part of an early product surveillance program. Methods: A prospective observational survey was conducted among orthopedic surgeons in the United States and Canada who had performed surgery using the fracture stem. Case-level evaluations of intraoperative handling, technical features, and surgeon-reported comparisons with routinely used implant systems were collected. Descriptive statistics were used to summarize survey responses. Results: Twenty-six orthopedic surgeons submitted feedback on 47 surgical cases (45 primary cases, 2 revisions), including predominantly reverse configurations (46/47) and one hemiarthroplasty construct. All available stem fixation methods were used: cementless without interlocking screws ( n = 24), cementless with interlocking screws ( n = 14), and cemented ( n = 9). Surgeons reported high levels of satisfaction and favorable ratings for ease of use. Across multiple comparative dimensions, the fracture system was frequently rated favorably compared with surgeons’ routinely used systems. Twenty-five of 26 participating surgeons indicated that they would consider using the system in future cases and would recommend it to others (missing data for one surgeon). Qualitative feedback described perceived benefits related to specific design features, including press-fit capability, bone graft window, proximal stem design, and the option for interlocking screw fixation. Conclusions: Surgeons reported favorable early intraoperative impressions of this fracture system. These findings provide exploratory insights into surgeon-reported usability and perceived design characteristics under early real-world use. Further studies are required to evaluate the clinical relevance of these surgeon-reported perceptions. Level of evidence: IV.
- 12 August 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1) , 685
Open AccessEarly surgeon experience with a fracture-specific humeral stem for proximal humerus fractures: a multicenter survey of predominantly reverse shoulder arthroplasty cases with an illustrative case
Background: Shoulder arthroplasty has become an established treatment option for displaced and complex proximal humeral fractures, particularly in elderly patients. Fracture-specific stems are increasingly used in clinical practice; however, early data on surgeon experience with newly introduced convertible stem designs remain limited. This study aimed to assess orthopedic surgeons’ early intraoperative experience with a newly developed humeral fracture system (Tornier Perform Humeral System – Fracture, Tornier Inc., a wholly owned subsidiary of Stryker, Bloomington, MN, USA) using a structured survey as part of an early product surveillance program. Methods: A prospective observational survey was conducted among orthopedic surgeons in the United States and Canada who had performed surgery using the fracture stem. Case-level evaluations of intraoperative handling, technical features, and surgeon-reported comparisons with routinely used implant systems were collected. Descriptive statistics were used to summarize survey responses. Results: Twenty-six orthopedic surgeons submitted feedback on 47 surgical cases (45 primary cases, 2 revisions), including predominantly reverse configurations (46/47) and one hemiarthroplasty construct. All available stem fixation methods were used: cementless without interlocking screws ( n = 24), cementless with interlocking screws ( n = 14), and cemented ( n = 9). Surgeons reported high levels of satisfaction and favorable ratings for ease of use. Across multiple comparative dimensions, the fracture system was frequently rated favorably compared with surgeons’ routinely used systems. Twenty-five of 26 participating surgeons indicated that they would consider using the system in future cases and would recommend it to others (missing data for one surgeon). Qualitative feedback described perceived benefits related to specific design features, including press-fit capability, bone graft window, proximal stem design, and the option for interlocking screw fixation. Conclusions: Surgeons reported favorable early intraoperative impressions of this fracture system. These findings provide exploratory insights into surgeon-reported usability and perceived design characteristics under early real-world use. Further studies are required to evaluate the clinical relevance of these surgeon-reported perceptions. Level of evidence: IV.
- Open Access
- 16 June 2024
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 4 (4) , 783-789
Use of pre-operative 3D planning software for revision shoulder arthroplasty: clinical experience data from a survey in a real-world setting
- 16 June 2024
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 4 (4) , 783-789
Open AccessUse of pre-operative 3D planning software for revision shoulder arthroplasty: clinical experience data from a survey in a real-world setting
- Open Access
- 30 May 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 189
Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study
The importance of the tip-apex distance (TAD) to predict the cut-out risk of fixed angle hip implants has been widely discussed in the scientific literature. Intra-operative determination of TAD is difficult and can be hampered by image quality, body habitus, and image projection. The purpose of this paper is to evaluate, through a cadaveric study, a novel computer assisted surgery system (ADAPT), which is intended for intraoperative optimisation of lag screw positioning during antegrade femoral nailing. A 3D measure for optimal lag screw position, the tip-to-head-surface distance (TSD), is introduced.
- 30 May 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 189
Open AccessImproved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study
The importance of the tip-apex distance (TAD) to predict the cut-out risk of fixed angle hip implants has been widely discussed in the scientific literature. Intra-operative determination of TAD is difficult and can be hampered by image quality, body habitus, and image projection. The purpose of this paper is to evaluate, through a cadaveric study, a novel computer assisted surgery system (ADAPT), which is intended for intraoperative optimisation of lag screw positioning during antegrade femoral nailing. A 3D measure for optimal lag screw position, the tip-to-head-surface distance (TSD), is introduced.