Orcun Gurbuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Orcun Gurbuz has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Abdulkadir Ercan
Department of Cardiovascular Surgery, Balikesir University, School of Medicine, 10010, Balikesir, Turkey
4 shared publications Abdulkadir Ercan
Department of Cardiovascular Surgery, Balıkesir University Medical Faculty, Bigadiç, 10145 Balıkesir, Turkey
3 shared publicationsGencehan Kumtepe
Department of Cardiovascular Surgery, Balıkesir University Medical Faculty, Bigadiç, 10145 Balıkesir, Turkey
3 shared publications- Gencehan Kumtepe
Department of Cardiovascular Surgery, Isparta City Hospital, Isparta, Turkey
3 shared publications Hakan Ozkan
Department Of Cardiology, Bahcesehir University Faculty of Medicine, Istanbul, Turkey
2 shared publications- Hakan Ozkan
Department Of Cardiology, Bahcesehir University Faculty of Medicine, Istanbul, Turkey.
2 shared publications
Latest Publications
- Open Access
- 3 March 2017
- Published by Clinics Cardive Publishing in CardioVascular Journal of Africa
- Vol. 28 (1) , 30-35
A comparison of off- and on-pump beating-heart coronary artery bypass surgery on long-term cardiovascular events
Our aim was to compare short-term outcomes and long-term major adverse cardiovascular event (MACE) -free survival and independent predictors of long-term MACE after off-pump (OPCAB) versus on-pump beating-heart (ONBHCAB) coronary artery bypass grafting (CABG). We retrospectively reviewed data of all consecutive patients who underwent elective CABG, performed by the same surgeon, from January 2003 to October 2009. A propensity score analysis was carried out to adjust for baseline characteristics and a total of 398 patients were included: ONBHCAB (n = 181), OPCAB (n = 217). OPCAB was associated with significantly shorter ventilation times (p < 0.001), intensive care unit stay (p < 0.001) and hospital stay (p < 0.001). The total blood loss was significantly more in the ONBHCAB group (p < 0.001), and accordingly, the number of transfused blood units was significantly lower in the OPCAB group (p < 0.001). Incidence of peri-operative renal complications were significantly higher in the ONBHCAB group (p = 0.004). The OPCAB group showed significantly lower long-term MACE-free survival (p = 0.029). The mean number of transfused blood units was the only independent predictor of MACE (HR: 1.218, 95% CI: 1.089-1.361; p = 0.001). OPCAB provided better long-term MACE-free survival compared with ONBHCAB. Fewer units of blood transfused following OPCAB surgery may have been the main reason for this result.
- 3 March 2017
- Published by Clinics Cardive Publishing in CardioVascular Journal of Africa
- Vol. 28 (1) , 30-35
Open AccessA comparison of off- and on-pump beating-heart coronary artery bypass surgery on long-term cardiovascular events
Our aim was to compare short-term outcomes and long-term major adverse cardiovascular event (MACE) -free survival and independent predictors of long-term MACE after off-pump (OPCAB) versus on-pump beating-heart (ONBHCAB) coronary artery bypass grafting (CABG). We retrospectively reviewed data of all consecutive patients who underwent elective CABG, performed by the same surgeon, from January 2003 to October 2009. A propensity score analysis was carried out to adjust for baseline characteristics and a total of 398 patients were included: ONBHCAB (n = 181), OPCAB (n = 217). OPCAB was associated with significantly shorter ventilation times (p < 0.001), intensive care unit stay (p < 0.001) and hospital stay (p < 0.001). The total blood loss was significantly more in the ONBHCAB group (p < 0.001), and accordingly, the number of transfused blood units was significantly lower in the OPCAB group (p < 0.001). Incidence of peri-operative renal complications were significantly higher in the ONBHCAB group (p = 0.004). The OPCAB group showed significantly lower long-term MACE-free survival (p = 0.029). The mean number of transfused blood units was the only independent predictor of MACE (HR: 1.218, 95% CI: 1.089-1.361; p = 0.001). OPCAB provided better long-term MACE-free survival compared with ONBHCAB. Fewer units of blood transfused following OPCAB surgery may have been the main reason for this result.
- Open Access
- 9 April 2016
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 11 (1) , 48
Red blood cell distribution width predicts long term cardiovascular event after on-pump beating coronary artery bypass grafting
Reports investigating the predictive value of red cell distribution width (RDW) on major cardiac and cardiovascular event (MACCE) following coronary artery bypass grafting (CABG) have major limitations, including lack of elimination of common factors affecting RDW levels, such as anemia. The purpose of this study is to identify the real effect of higher RDW level, free from the other factors, on MACCE following CABG. Data of 500 consecutive, non-anemic patients (77.2 % male and mean age 63.05 ± 9.24) undergoing ONBHCAB between January 2007 and January 2010, were analyzed retrospectively. Overall MACCE was 7.8 % of all cases. Mean follow-up was 66.5 ± 9.96 months. In multivariate Cox regression analysis, RDW (P = 0.022) remained the only independent predictor of MACCE and the ROC analyze revealed an RDW cut-off value of 13.95 % predicting MACCE. Therefore, patients were grouped on this cut-off value. There were 238 patients in the lower RDW group (Group 1) and 262 patients in the higher RDW group (Group 2). Kaplan–Meier survival analysis of freedom from MACCE revealed significantly lower event free survival in Group 2 (P < 0.001 by the log-rank test). Group 2 showed a higher MACCE incidence in 1 year (P = 0.030), in 3 years (P < 0.001) and in 6 years (P < 0.001). The long-term follow-up was similar regarding noncardiovascular mortality. An RDW level greater than 13.95 % in hospital admission is independently associated with an increased incidence of MACCE after CABG. Physicians should be more aggressive in the management of these patients.
- 9 April 2016
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 11 (1) , 48
Open AccessRed blood cell distribution width predicts long term cardiovascular event after on-pump beating coronary artery bypass grafting
Reports investigating the predictive value of red cell distribution width (RDW) on major cardiac and cardiovascular event (MACCE) following coronary artery bypass grafting (CABG) have major limitations, including lack of elimination of common factors affecting RDW levels, such as anemia. The purpose of this study is to identify the real effect of higher RDW level, free from the other factors, on MACCE following CABG. Data of 500 consecutive, non-anemic patients (77.2 % male and mean age 63.05 ± 9.24) undergoing ONBHCAB between January 2007 and January 2010, were analyzed retrospectively. Overall MACCE was 7.8 % of all cases. Mean follow-up was 66.5 ± 9.96 months. In multivariate Cox regression analysis, RDW (P = 0.022) remained the only independent predictor of MACCE and the ROC analyze revealed an RDW cut-off value of 13.95 % predicting MACCE. Therefore, patients were grouped on this cut-off value. There were 238 patients in the lower RDW group (Group 1) and 262 patients in the higher RDW group (Group 2). Kaplan–Meier survival analysis of freedom from MACCE revealed significantly lower event free survival in Group 2 (P < 0.001 by the log-rank test). Group 2 showed a higher MACCE incidence in 1 year (P = 0.030), in 3 years (P < 0.001) and in 6 years (P < 0.001). The long-term follow-up was similar regarding noncardiovascular mortality. An RDW level greater than 13.95 % in hospital admission is independently associated with an increased incidence of MACCE after CABG. Physicians should be more aggressive in the management of these patients.
- Open Access
- 19 March 2015
- Published by Hindawi Limited in Case Reports in Surgery
- Vol. 2015, 1-4
Intramyocardial Dissection following Postinfarction Ventricular Wall Rupture Contained by Surrounding Postoperative Adhesions
Introduction. Dissection of the myocardium is a rare form of cardiac rupture, caused by a hemorrhagic dissection among the spiral myocardial fibers, its diagnosis is rarely established before the operation or death, and extremely few cases have been reported in the literature and none of these cases seem to have a history of previous cardiac surgery which makes our report unique.Case Presentation. A 61-year-old female patient was admitted into the emergency room with complaints of progressive chest pain for 2 days. She had a history of second time prosthetic aortic valve replacement and was under anticoagulation therapy. She was diagnosed with an acute inferoposterior myocardial infarction and underwent emergency coronary angiography revealing spontaneous recanalization of the right coronary artery. During the follow-up, she developed cardiogenic shock and a new occurring systolic ejection murmur. Transthoracic echocardiography showed a left ventricular free wall rupture; then, she was taken in for emergency surgery. During the operation, a rupture zone and a wide intramyocardial dissecting area were detected. Intraventricular patch repair technic with autologous pericardial patch was used to exclude the ruptured area. Following the warming period, despite adequate hemostasis, hemorrhage around suture lines progressively increased, leading to the patient’s death.Conclusion. Pericardial adhesions might contain left ventricular rupture leading to intramyocardial dissection.
- 19 March 2015
- Published by Hindawi Limited in Case Reports in Surgery
- Vol. 2015, 1-4
Open AccessIntramyocardial Dissection following Postinfarction Ventricular Wall Rupture Contained by Surrounding Postoperative Adhesions
Introduction. Dissection of the myocardium is a rare form of cardiac rupture, caused by a hemorrhagic dissection among the spiral myocardial fibers, its diagnosis is rarely established before the operation or death, and extremely few cases have been reported in the literature and none of these cases seem to have a history of previous cardiac surgery which makes our report unique.Case Presentation. A 61-year-old female patient was admitted into the emergency room with complaints of progressive chest pain for 2 days. She had a history of second time prosthetic aortic valve replacement and was under anticoagulation therapy. She was diagnosed with an acute inferoposterior myocardial infarction and underwent emergency coronary angiography revealing spontaneous recanalization of the right coronary artery. During the follow-up, she developed cardiogenic shock and a new occurring systolic ejection murmur. Transthoracic echocardiography showed a left ventricular free wall rupture; then, she was taken in for emergency surgery. During the operation, a rupture zone and a wide intramyocardial dissecting area were detected. Intraventricular patch repair technic with autologous pericardial patch was used to exclude the ruptured area. Following the warming period, despite adequate hemostasis, hemorrhage around suture lines progressively increased, leading to the patient’s death.Conclusion. Pericardial adhesions might contain left ventricular rupture leading to intramyocardial dissection.
- 13 January 2015
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- p. 98-104
Evaluation of polylactide film for prevention of pericardial adhesion in a rabbit model
- 13 January 2015
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- p. 98-104
Evaluation of polylactide film for prevention of pericardial adhesion in a rabbit model
- Open Access
- 17 December 2014
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 9 (1) , 187
Case report: paravalvular leak as a complication of percutaneous catheter ablation for atrial fibrillation
An increasing number of reports reveal the safety and efficacy of catheter ablation for atrial fibrillation therapy even in patients with a history of prosthetic heart valve. This case report presents a 60 year old female patient who had a prosthetic mitral paravalvular leak as a complication of radiofrequency ablation. Surgery revealed a 15 mm hole and three broken knots in the posterolateral mitral annulus. This report demonstrates radiofrequency ablation for atrial fibrillation in patients with prosthetic mitral valve may cause a paravalvular leak likely as a result of thermal injury. Moreover, patient can be asymptomatic at first. The clinician should keep in mind such complication and the patient should be evaluated in terms of paravalvular leakage.
- 17 December 2014
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 9 (1) , 187
Open AccessCase report: paravalvular leak as a complication of percutaneous catheter ablation for atrial fibrillation
An increasing number of reports reveal the safety and efficacy of catheter ablation for atrial fibrillation therapy even in patients with a history of prosthetic heart valve. This case report presents a 60 year old female patient who had a prosthetic mitral paravalvular leak as a complication of radiofrequency ablation. Surgery revealed a 15 mm hole and three broken knots in the posterolateral mitral annulus. This report demonstrates radiofrequency ablation for atrial fibrillation in patients with prosthetic mitral valve may cause a paravalvular leak likely as a result of thermal injury. Moreover, patient can be asymptomatic at first. The clinician should keep in mind such complication and the patient should be evaluated in terms of paravalvular leakage.
- Open Access
- 16 October 2014
- Published by Hindawi Limited in Case Reports in Medicine
- Vol. 2014, 1-3
Femoral Nerve Palsy due to Anticoagulant Induced Retroperitoneal Hematoma
A forty-one-year-old man who, sought evaluation for a sudden hip flexion contracture and groin pain with a history of mechanical mitral valve replacement, had been misdiagnosed and treated as having lumbar discopathy for two days. This patient finally was diagnosed with compressive femoral neuropathy due to warfarin-induced retroperitoneal hematoma and successfully managed nonoperatively. This case is reported in order to draw attention to this rare presentation.
- 16 October 2014
- Published by Hindawi Limited in Case Reports in Medicine
- Vol. 2014, 1-3
Open AccessFemoral Nerve Palsy due to Anticoagulant Induced Retroperitoneal Hematoma
A forty-one-year-old man who, sought evaluation for a sudden hip flexion contracture and groin pain with a history of mechanical mitral valve replacement, had been misdiagnosed and treated as having lumbar discopathy for two days. This patient finally was diagnosed with compressive femoral neuropathy due to warfarin-induced retroperitoneal hematoma and successfully managed nonoperatively. This case is reported in order to draw attention to this rare presentation.
- Open Access
- 19 June 2014
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 9 (1) , 105
A comparison of off-pump and on-pump coronary bypass surgery in patients with low EuroSCORE
The aim of the present study was to evaluate and compare postoperative short-term, mid-term and long-term outcomes of coronary artery bypass surgery performed with or without cardiopulmonary bypass in patients with a low European System for Cardiac Operative Risk Evaluation score.
- 19 June 2014
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 9 (1) , 105
Open AccessA comparison of off-pump and on-pump coronary bypass surgery in patients with low EuroSCORE
The aim of the present study was to evaluate and compare postoperative short-term, mid-term and long-term outcomes of coronary artery bypass surgery performed with or without cardiopulmonary bypass in patients with a low European System for Cardiac Operative Risk Evaluation score.
- 1 January 2014
- Vol. 64 (1) , 28-32
Vascular complications of intra-aortic balloon pump usage in coronary bypass surgery: 18 years of experience.
To evaluate the vascular complication incidence related to intra-aortic balloon pump usage during coronary bypass surgery and possible risk factors. The retrospective study was conducted at Uludog University Hospital, Turkey, and comprised 147 cases in which intra-aortic balloon pump was used during coronary artery bypass surgery between January 1994 and December 2011. Data was examined in terms of age, gender, diabetes mellitus, hypertension, smoking, peripheral vascular disease, pre-operative serum creatinine, history of congestive heart failure, left ventricular ejection fraction, previous infarction and cardiac functional capacity. Time, indication, treatment duration, technique of insertion and complications were recorded about the balloon insertion. Patients in whom peripheral vascular complication developed were evaluated with pulse examination, Doppler ultrasound and angiography. Logistic regression analyses were carried out with the purpose of determining the relation between pre-operative clinical variables and vascular complications and mortality. Of the total, 105 (71%) were males and 42 (28%) were females. The overall mean age was 62.4 +/- 10.1 years. Besides, 16 (41%) cases had diabetes mellitus and 30 (20%) had peripheral artery disease. The mean Euroscore was 7.6 +/- 4.8. Intra-aortic balloon pump was inserted in 16 (10.8%) due to pre-operative high risk and in 75 (51%) cases due to hypotension being non-responsive to inotropes. Balloon catheter was placed with percutaneous technique in 141 (96%) cases and sheath wasn't used in 44 (29%). The balloon stayed for 2.9 +/- 2.1 days on average. Balloon rupture developed in 1 (0.6%) case. Mortality resulted in 58 (39%) cases. Euroscore (p=0.012), staying in hospital (p=0.005), low ejection fraction (p=0.018), hypertension existence (p=0.003) in multivariate logistic regression analyses were found significant in terms of affecting mortality. Duration of therapy (p<0.001), existence of sheath (p=0.002), and existence of peripheral vascular disease (p<0.001) were found significant as factors affecting the development of vascular complication. Intra-aortic balloon pump provides mechanical circulation assistance during coronary artery surgery, but peripheral vascular system should be well evaluated in order to avoid vascular complications and the balloon catheter should be placed without the sheath if necessary. The duration of the therapy is a risk factor for the development of vascular complication.
- 1 January 2014
- Vol. 64 (1) , 28-32
Vascular complications of intra-aortic balloon pump usage in coronary bypass surgery: 18 years of experience.
To evaluate the vascular complication incidence related to intra-aortic balloon pump usage during coronary bypass surgery and possible risk factors. The retrospective study was conducted at Uludog University Hospital, Turkey, and comprised 147 cases in which intra-aortic balloon pump was used during coronary artery bypass surgery between January 1994 and December 2011. Data was examined in terms of age, gender, diabetes mellitus, hypertension, smoking, peripheral vascular disease, pre-operative serum creatinine, history of congestive heart failure, left ventricular ejection fraction, previous infarction and cardiac functional capacity. Time, indication, treatment duration, technique of insertion and complications were recorded about the balloon insertion. Patients in whom peripheral vascular complication developed were evaluated with pulse examination, Doppler ultrasound and angiography. Logistic regression analyses were carried out with the purpose of determining the relation between pre-operative clinical variables and vascular complications and mortality. Of the total, 105 (71%) were males and 42 (28%) were females. The overall mean age was 62.4 +/- 10.1 years. Besides, 16 (41%) cases had diabetes mellitus and 30 (20%) had peripheral artery disease. The mean Euroscore was 7.6 +/- 4.8. Intra-aortic balloon pump was inserted in 16 (10.8%) due to pre-operative high risk and in 75 (51%) cases due to hypotension being non-responsive to inotropes. Balloon catheter was placed with percutaneous technique in 141 (96%) cases and sheath wasn't used in 44 (29%). The balloon stayed for 2.9 +/- 2.1 days on average. Balloon rupture developed in 1 (0.6%) case. Mortality resulted in 58 (39%) cases. Euroscore (p=0.012), staying in hospital (p=0.005), low ejection fraction (p=0.018), hypertension existence (p=0.003) in multivariate logistic regression analyses were found significant in terms of affecting mortality. Duration of therapy (p<0.001), existence of sheath (p=0.002), and existence of peripheral vascular disease (p<0.001) were found significant as factors affecting the development of vascular complication. Intra-aortic balloon pump provides mechanical circulation assistance during coronary artery surgery, but peripheral vascular system should be well evaluated in order to avoid vascular complications and the balloon catheter should be placed without the sheath if necessary. The duration of the therapy is a risk factor for the development of vascular complication.
- Open Access
- 1 January 2014
- Published by Elmer Press, Inc. in Journal of Medical Cases
- Vol. 5 (10) , 532-534
Massive Pulmonary Embolism as a Complication of Coronary Angiography and Its Successful Treatment With Half-Dose Alteplase
A 64-year-old woman was admitted to our emergency room for shortness of breath, chest pain and syncope. Her symptoms started suddenly 2 hours before admission when she was resting at home. She had a history of coronary angiography 2 weeks ago and undergone surgical repair of femoral pseudoaneurysm. She was diagnosed with massive pulmonary embolism and successfully managed with half-dose alteplase and discharged with warfarin treatment 5 days after the admission. This case is presented in order to draw attention to this rare presentation and the use of half-dose systemic thrombolytic in a patient with a history of vascular surgery within 2 weeks. J Med Cases. 2014;5(10):532-534 doi: http://dx.doi.org/10.14740/jmc1934w
- 1 January 2014
- Published by Elmer Press, Inc. in Journal of Medical Cases
- Vol. 5 (10) , 532-534
Open AccessMassive Pulmonary Embolism as a Complication of Coronary Angiography and Its Successful Treatment With Half-Dose Alteplase
A 64-year-old woman was admitted to our emergency room for shortness of breath, chest pain and syncope. Her symptoms started suddenly 2 hours before admission when she was resting at home. She had a history of coronary angiography 2 weeks ago and undergone surgical repair of femoral pseudoaneurysm. She was diagnosed with massive pulmonary embolism and successfully managed with half-dose alteplase and discharged with warfarin treatment 5 days after the admission. This case is presented in order to draw attention to this rare presentation and the use of half-dose systemic thrombolytic in a patient with a history of vascular surgery within 2 weeks. J Med Cases. 2014;5(10):532-534 doi: http://dx.doi.org/10.14740/jmc1934w