Ligang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ligang Chen has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Lei Gao
Heilongjiang River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Harbin, China
5 shared publicationsHaochi Liu
Department of Chemistry, College of Science, Northeast Forestry University, Harbin, China
4 shared publications- Jie Ding
National Engineering Research Center for Safe Disposal and Resources Recovery of Sludge, Harbin Institute of Technology, Harbin 150090, China
4 shared publications Chenyu Li
Center of Disease Control of Heilongjiang Province, Harbin, China
3 shared publicationsDongli Qin
Heilongjiang River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Harbin, China
3 shared publicationsTing Liang
Department of Chemistry, College of Science, Northeast Forestry University, 26 Hexing Road, Harbin 150040, PR China
3 shared publications
Latest Publications
- 27 June 2022
- Published by Elsevier in Microchemical Journal
- Vol. 181, 107742
Facile off-on fluorescence biosensing of human papillomavirus using DNA probe coupled with sunflower seed shells carbon dots
- 27 June 2022
- Published by Elsevier in Microchemical Journal
- Vol. 181, 107742
Facile off-on fluorescence biosensing of human papillomavirus using DNA probe coupled with sunflower seed shells carbon dots
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1609, 460453
Mesoporous structured molecularly imprinted polymer with restricted access function for highly selective extraction of chlorpyrifos from soil
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1609, 460453
Mesoporous structured molecularly imprinted polymer with restricted access function for highly selective extraction of chlorpyrifos from soil
- 6 October 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (23) , 3563-3570
Extraction of matrine from soil with matrix solid‐phase dispersion by molecularly imprinted polymers derived from lignin‐based Pickering emulsions
Molecular imprinted polymers prepared by Pickering emulsion method with lignin as stable particle were used as dispersants in matrix solid phase dispersion, followed by ultra performance liquid chromatography‐tandem mass spectrometry analysis to research the degradation behavior of matrine in soil. The molecular imprinted polymers have regularly morphology and uniformly particles. Moreover, the adsorption experiments and the conditions of matrix solid phase dispersion were discussed. With the optimal conditions of matrix solid phase dispersion, the recoveries of matrine were 95.4%‐98.2%, Relative standard deviations were 0.6%‐5.1% and the detection limit was 5 ng g−1. What's more, the degradation behavior of matrine in soil was researched, it indicated the half‐life of matrine was 2.7‐3.2 days, and it was an environment friendly botanical pesticide. The method was successfully applied to separate and analyze matrine in soil samples can decrease analysis time, save organic solvents and improve the selectivity. This article is protected by copyright. All rights reserved
- 6 October 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (23) , 3563-3570
Extraction of matrine from soil with matrix solid‐phase dispersion by molecularly imprinted polymers derived from lignin‐based Pickering emulsions
Molecular imprinted polymers prepared by Pickering emulsion method with lignin as stable particle were used as dispersants in matrix solid phase dispersion, followed by ultra performance liquid chromatography‐tandem mass spectrometry analysis to research the degradation behavior of matrine in soil. The molecular imprinted polymers have regularly morphology and uniformly particles. Moreover, the adsorption experiments and the conditions of matrix solid phase dispersion were discussed. With the optimal conditions of matrix solid phase dispersion, the recoveries of matrine were 95.4%‐98.2%, Relative standard deviations were 0.6%‐5.1% and the detection limit was 5 ng g−1. What's more, the degradation behavior of matrine in soil was researched, it indicated the half‐life of matrine was 2.7‐3.2 days, and it was an environment friendly botanical pesticide. The method was successfully applied to separate and analyze matrine in soil samples can decrease analysis time, save organic solvents and improve the selectivity. This article is protected by copyright. All rights reserved
- 20 July 2019
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (8) , 1-10
Molecularly imprinted mesoporous silica incorporating C3N4 dots and CdTe quantum dots as ratiometric fluorescent probe for determination of Malachite Green
A new dual-emission ratiometric fluorescent probe was synthesized and successfully used for the determination of Malachite Green (MG) in fish farming water. The ratiometric fluorescent probe was successfully composited by sol-gel method using C3N4 and CdTe quantum dots as fluorescent materials combined with mesoporous molecularly imprinted polymers. MG quenches the red fluorescence of the CdTe QDs (with excitation/emission wavelengths at 350/680 nm) while the blue fluorescence of C3N4 (with excitation/emission wavelengths at 350/458 nm) remains unchanged. The change of fluorescence color and fluorescence intensity ratio can be successfully used for quantification of malachite green. In addition, the mesoporous structure has a large surface and good adsorption capacity for malachite green. The normalized intensity of fluorescence increases linearly in the 50–1000 ng·mL−1 MG concentration range, and the detection limit is 10 ng·mL−1. The imprinting factor is 3.2. The nanoprobe was applied to the determination of MG in fish farming water samples. Recoveries and relative standard deviations were 92.5–97.8% and 2.5–6.2%, respectively. Schematic representation of synthesis of molecularly imprinted mesoporous silica ratiometric fluorescent probes incorporating C3N4 dots and CdTe quantum dots for determination of malachite green.
- 20 July 2019
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (8) , 1-10
Molecularly imprinted mesoporous silica incorporating C3N4 dots and CdTe quantum dots as ratiometric fluorescent probe for determination of Malachite Green
A new dual-emission ratiometric fluorescent probe was synthesized and successfully used for the determination of Malachite Green (MG) in fish farming water. The ratiometric fluorescent probe was successfully composited by sol-gel method using C3N4 and CdTe quantum dots as fluorescent materials combined with mesoporous molecularly imprinted polymers. MG quenches the red fluorescence of the CdTe QDs (with excitation/emission wavelengths at 350/680 nm) while the blue fluorescence of C3N4 (with excitation/emission wavelengths at 350/458 nm) remains unchanged. The change of fluorescence color and fluorescence intensity ratio can be successfully used for quantification of malachite green. In addition, the mesoporous structure has a large surface and good adsorption capacity for malachite green. The normalized intensity of fluorescence increases linearly in the 50–1000 ng·mL−1 MG concentration range, and the detection limit is 10 ng·mL−1. The imprinting factor is 3.2. The nanoprobe was applied to the determination of MG in fish farming water samples. Recoveries and relative standard deviations were 92.5–97.8% and 2.5–6.2%, respectively. Schematic representation of synthesis of molecularly imprinted mesoporous silica ratiometric fluorescent probes incorporating C3N4 dots and CdTe quantum dots for determination of malachite green.
- 30 May 2019
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (21) , 5519-5530
Synthesis of molecularly imprinted fluorescent probe based on biomass-derived carbon quantum dots for detection of mesotrione
A novel fluorescent probe based on molecularly imprinted polymers (MIPs) coupled with carbon quantum dots (CQDs) was fabricated and successfully used for selective recognition of mesotrione. In this probe, the biomass-derived CQDs were prepared through a hydrothermal method using mango peels as carbon source, and the whole synthesis procedure was green without chemical reagents. The CQDs were encapsulated into MIPs by using sol-gel technology. After removal of the template molecule mesotrione, specific binding sites are formed and there is electrostatic attraction between the probe and the template molecule. The synthetic CQDs@MIPs were able to selectively capture the target mesotrione with fluorescence quenching via the specific interaction between mesotrione and the recognition cavities. The probe was used for determination of mesotrione in corn to verify the practicality of the proposed method. The detection limit of mesotrione was 4.7 nmol L−1, and the linear range was 15 nmol L−1 to 3000 nmol L−1. Meanwhile, the recoveries of this method for mesotrione were 91.4–96.2%, and the relative standard deviations (RSDs) were 3.2–6.1%. This work provides a novel research method to synthesize CQDs@MIPs with high selectivity (imprinting factor = 5.6), and which can be used for convenient, rapid recognition and sensitive detection of trace compounds from complex matrices.
- 30 May 2019
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (21) , 5519-5530
Synthesis of molecularly imprinted fluorescent probe based on biomass-derived carbon quantum dots for detection of mesotrione
A novel fluorescent probe based on molecularly imprinted polymers (MIPs) coupled with carbon quantum dots (CQDs) was fabricated and successfully used for selective recognition of mesotrione. In this probe, the biomass-derived CQDs were prepared through a hydrothermal method using mango peels as carbon source, and the whole synthesis procedure was green without chemical reagents. The CQDs were encapsulated into MIPs by using sol-gel technology. After removal of the template molecule mesotrione, specific binding sites are formed and there is electrostatic attraction between the probe and the template molecule. The synthetic CQDs@MIPs were able to selectively capture the target mesotrione with fluorescence quenching via the specific interaction between mesotrione and the recognition cavities. The probe was used for determination of mesotrione in corn to verify the practicality of the proposed method. The detection limit of mesotrione was 4.7 nmol L−1, and the linear range was 15 nmol L−1 to 3000 nmol L−1. Meanwhile, the recoveries of this method for mesotrione were 91.4–96.2%, and the relative standard deviations (RSDs) were 3.2–6.1%. This work provides a novel research method to synthesize CQDs@MIPs with high selectivity (imprinting factor = 5.6), and which can be used for convenient, rapid recognition and sensitive detection of trace compounds from complex matrices.
- 28 May 2019
- Published by Springer Nature in Food Analytical Methods
- Vol. 12 (9) , 1938-1948
Determination of Sulfonylurea Herbicides in Grain Samples by Matrix Solid-Phase Dispersion with Mesoporous Structured Molecularly Imprinted Polymer
- 28 May 2019
- Published by Springer Nature in Food Analytical Methods
- Vol. 12 (9) , 1938-1948
Determination of Sulfonylurea Herbicides in Grain Samples by Matrix Solid-Phase Dispersion with Mesoporous Structured Molecularly Imprinted Polymer
- 8 September 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 12 (1) , 217-228
Metal Organic Framework-Molecularly Imprinted Polymer as Adsorbent in Matrix Solid Phase Dispersion for Pyrethroids Residue Extraction from Wheat
- 8 September 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 12 (1) , 217-228
Metal Organic Framework-Molecularly Imprinted Polymer as Adsorbent in Matrix Solid Phase Dispersion for Pyrethroids Residue Extraction from Wheat
- 17 August 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (27) , 7103-7112
A fluorescent material for the detection of chlortetracycline based on molecularly imprinted silica–graphitic carbon nitride composite
A new fluorescent probe based on graphitic carbon nitride (g-C3N4) combined with molecularly imprinted silica was successfully fabricated and used to selectively recognize chlortetracycline (CTC). The g-C3N4 used in this study has the characteristics of low toxicity and high chemical stability. This synthetic composite was characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, UV spectroscopy, X-ray diffraction, and fluorescence spectroscopy. The material was used to detect CTC by the fluorescence quenching technique. The fluorescence quenching was due to g-C3N4 and the benzene ring of CTC through π–π electron donor–acceptor interaction and electrostatic force. Hydrogen bonds formed between CTC and 3-aminopropyltriethoxysilane during the polymerization process. Eventually, a considerable amount of selective recognition holes were formed in the composite material and could specifically recognize the template molecule CTC. In addition, the probe strategy was successfully applied to milk analysis, and the recoveries ranged from 90.1% to 95.7%, with relative standard deviations of 1.8–2.8%; the detection limit for CTC was 8 ng mL-1. The results indicate that this method combined the sensitivity of fluorescence detection with the excellent selectivity of a molecularly imprinted polymer. The new material can be widely used in the detection of dairy products.
- 17 August 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (27) , 7103-7112
A fluorescent material for the detection of chlortetracycline based on molecularly imprinted silica–graphitic carbon nitride composite
A new fluorescent probe based on graphitic carbon nitride (g-C3N4) combined with molecularly imprinted silica was successfully fabricated and used to selectively recognize chlortetracycline (CTC). The g-C3N4 used in this study has the characteristics of low toxicity and high chemical stability. This synthetic composite was characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, UV spectroscopy, X-ray diffraction, and fluorescence spectroscopy. The material was used to detect CTC by the fluorescence quenching technique. The fluorescence quenching was due to g-C3N4 and the benzene ring of CTC through π–π electron donor–acceptor interaction and electrostatic force. Hydrogen bonds formed between CTC and 3-aminopropyltriethoxysilane during the polymerization process. Eventually, a considerable amount of selective recognition holes were formed in the composite material and could specifically recognize the template molecule CTC. In addition, the probe strategy was successfully applied to milk analysis, and the recoveries ranged from 90.1% to 95.7%, with relative standard deviations of 1.8–2.8%; the detection limit for CTC was 8 ng mL-1. The results indicate that this method combined the sensitivity of fluorescence detection with the excellent selectivity of a molecularly imprinted polymer. The new material can be widely used in the detection of dairy products.
- 1 July 2018
- Published by Elsevier in Food Chemistry
- Vol. 255, 226-234
Magnetic molecular imprinting polymers based on three-dimensional (3D) graphene-carbon nanotube hybrid composites for analysis of melamine in milk powder
- 1 July 2018
- Published by Elsevier in Food Chemistry
- Vol. 255, 226-234
Magnetic molecular imprinting polymers based on three-dimensional (3D) graphene-carbon nanotube hybrid composites for analysis of melamine in milk powder
- 2 May 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (12) , 2604-2612
Analysis of tetracyclines from milk powder by molecularly imprinted solid‐phase dispersion based on a metal–organic framework followed by ultra high performance liquid chromatography with tandem mass spectrometry
A novel molecularly imprinted polymer that could selectively recognize tetracyclines in milk powder was synthesized using a metal–organic framework as a support material, tetracycline as template molecule, and 3‐aminophenylboronic acid as a functional monomer and a cross‐linking agent. The novel molecularly imprinted polymer was characterized by Fourier transform infrared spectrometry, transmission electron microscopy, X‐ray diffractometry, thermogravimetric analysis, and N2 adsorption/desorption measurements. The adsorption isotherms, adsorption kinetics, adsorption thermodynamics, and selective adsorption experiments of the novel molecularly imprinted polymer to tetracycline were also studied. The novel molecularly imprinted polymer was used as dispersant of matrix solid‐phase dispersion to extraction tetracyclines. After that, the tetracyclines extracted from milk powder were determined by ultra high performance liquid chromatography with tandem mass spectrometry. Under the optimal conditions, the detection limits of tetracyclines were 0.217–0.318 ng/g. The relative standard deviations of intra‐ and interday precision ranged from 3.8 to 6.9% and from 2.8 to 7.4%, respectively. In all three concentration levels (1.0, 10, 50 ng/g), the recoveries of tetracyclines ranged from 84.7 to 93.9%. The method was successfully applied to the determination of tetracyclines in milk powder.
- 2 May 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (12) , 2604-2612
Analysis of tetracyclines from milk powder by molecularly imprinted solid‐phase dispersion based on a metal–organic framework followed by ultra high performance liquid chromatography with tandem mass spectrometry
A novel molecularly imprinted polymer that could selectively recognize tetracyclines in milk powder was synthesized using a metal–organic framework as a support material, tetracycline as template molecule, and 3‐aminophenylboronic acid as a functional monomer and a cross‐linking agent. The novel molecularly imprinted polymer was characterized by Fourier transform infrared spectrometry, transmission electron microscopy, X‐ray diffractometry, thermogravimetric analysis, and N2 adsorption/desorption measurements. The adsorption isotherms, adsorption kinetics, adsorption thermodynamics, and selective adsorption experiments of the novel molecularly imprinted polymer to tetracycline were also studied. The novel molecularly imprinted polymer was used as dispersant of matrix solid‐phase dispersion to extraction tetracyclines. After that, the tetracyclines extracted from milk powder were determined by ultra high performance liquid chromatography with tandem mass spectrometry. Under the optimal conditions, the detection limits of tetracyclines were 0.217–0.318 ng/g. The relative standard deviations of intra‐ and interday precision ranged from 3.8 to 6.9% and from 2.8 to 7.4%, respectively. In all three concentration levels (1.0, 10, 50 ng/g), the recoveries of tetracyclines ranged from 84.7 to 93.9%. The method was successfully applied to the determination of tetracyclines in milk powder.