Michael Friedrich Russold
Research Subjects
Michael Friedrich Russold has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Augsten
Asklepios Neurological Clinic Falkenstein, 61462 Königstein-Falkenstein, Germany
2 shared publications - Christian Hofer
Department of Global Research, Otto Bock Healthcare Products GmbH, Vienna, Austria
2 shared publications - Constantin Wiesener
Control Systems Group of TU Berlin
2 shared publications - Franco Molteni
Villa Beretta Rehabilitation Center, Valduce Hospital, Lecco, Italy
2 shared publications - Giulio Gasperini
Villa Beretta Rehabilitation Center, Valduce Hospital
2 shared publications - Johannes Zajc
Ottobock Health Products GmbH
2 shared publications
Latest Publications
- Open Access
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4492-4503
A Novel Sensory Feedback Approach to Facilitate Both Predictive and Corrective Control of Grasping Force in Myoelectric Prostheses
Reliable force control is especially important when using myoelectric upper-limb prostheses as the force defines whether an object will be firmly grasped, damaged, or dropped. It is known from human motor control that the grasping of able-bodied subjects is based on a combination of anticipation and feedback correction. Inspired by this insight, the present study proposes a novel approach to provide artificial sensory feedback to the user of a myoelectric prosthesis using vibrotactile stimulation to facilitate both predictive and corrective processes characteristic of grasping in able-bodied people. Specifically, the level of EMG was conveyed to the subjects while closing the prosthesis (predictive strategy), whereas the actual grasping force was transmitted when the prosthesis closed (corrective strategy). To investigate if this combined EMG and force feedback is indeed an effective method to explicitly close the control loop, 16 able-bodied and 3 transradial amputee subjects performed a set of functional tasks, inspired by the “Box and Block” test, with six target force levels, in three conditions: no feedback, only EMG feedback, and combined feedback. The highest overall performance in able-bodied subjects was obtained with combined feedback (79.6±9.9%), whereas the lowest was achieved with no feedback (53±11.5%). The combined feedback, however, increased the task completion time compared to the other two conditions. A similar trend was obtained also in three amputee subjects. The results, therefore, indicate that the feedback inspired by human motor control is indeed an effective approach to improve prosthesis grasping in realistic conditions when other sources of feedback (vision and audition) are not blocked.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4492-4503
Open AccessA Novel Sensory Feedback Approach to Facilitate Both Predictive and Corrective Control of Grasping Force in Myoelectric Prostheses
Reliable force control is especially important when using myoelectric upper-limb prostheses as the force defines whether an object will be firmly grasped, damaged, or dropped. It is known from human motor control that the grasping of able-bodied subjects is based on a combination of anticipation and feedback correction. Inspired by this insight, the present study proposes a novel approach to provide artificial sensory feedback to the user of a myoelectric prosthesis using vibrotactile stimulation to facilitate both predictive and corrective processes characteristic of grasping in able-bodied people. Specifically, the level of EMG was conveyed to the subjects while closing the prosthesis (predictive strategy), whereas the actual grasping force was transmitted when the prosthesis closed (corrective strategy). To investigate if this combined EMG and force feedback is indeed an effective method to explicitly close the control loop, 16 able-bodied and 3 transradial amputee subjects performed a set of functional tasks, inspired by the “Box and Block” test, with six target force levels, in three conditions: no feedback, only EMG feedback, and combined feedback. The highest overall performance in able-bodied subjects was obtained with combined feedback (79.6±9.9%), whereas the lowest was achieved with no feedback (53±11.5%). The combined feedback, however, increased the task completion time compared to the other two conditions. A similar trend was obtained also in three amputee subjects. The results, therefore, indicate that the feedback inspired by human motor control is indeed an effective approach to improve prosthesis grasping in realistic conditions when other sources of feedback (vision and audition) are not blocked.
- Open Access
- 23 February 2022
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 480 (6) , 1191-1204
Feasibility of a Wireless Implantable Multi-electrode System for High-bandwidth Prosthetic Interfacing: Animal and Cadaver Study
Background: Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. Questions/purposes: The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. Methods: We evaluated the biocompatibility of the system’s intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. Results: Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. Conclusion: As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. Clinical Relevance: In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.
- 23 February 2022
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 480 (6) , 1191-1204
Open AccessFeasibility of a Wireless Implantable Multi-electrode System for High-bandwidth Prosthetic Interfacing: Animal and Cadaver Study
Background: Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. Questions/purposes: The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. Methods: We evaluated the biocompatibility of the system’s intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. Results: Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. Conclusion: As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. Clinical Relevance: In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.
- Open Access
Reactive Exercises with Interactive Objects: Interim Analysis of a Randomized Trial on Task-Driven NMES Grasp Rehabilitation for Subacute and Early Chronic Stroke Patients
Enriched environments and tools are believed to promote grasp rehabilitation after stroke. We designed S2, an interactive grasp rehabilitation system consisting of smart objects, custom orthoses for selective grasp constraining, and an electrode array system for forearm NMES. Motor improvements and perceived usability of a new enriched upper limb training system for sub-acute stroke patients was assessed in this interim analysis. Inclusion criteria: sub-acute stroke patients with , ipsilesional , and contralesional . Effects of 30-min therapy supplements, conventional vs. S2 prototype, are compared through a parallel two-arms dose-matched open-label trial, lasting 27 sessions. Clinical centres: Asklepios Neurologische Klinik Falkenstein, Königstein im Taunus, Germany, and Clinica Villa Beretta, Costa Masnaga, Italy. Assessment scales: ARAT, System Usability, and Technology Acceptance. Methodology: 26 participants were block randomized, allocated to the study (control , experimental ) and underwent the training protocol. Among them, 11 participants with ARAT score at inclusion below 35, n = 6 in the experimental group, and n = 5 in the control group were analysed. Results: participants in the enriched treatment group displayed a larger improvement in the ARAT scale (+14.9 pts, ). Perceived usability differed between clinics. No adverse effect was observed in relation to the treatments. Trial status: closed. Conclusions: The S2 system, developed according to shared clinical directives, was tested in a clinical proof of concept. Variations of ARAT scores confirm the feasibility of clinical investigation for hand rehabilitation after stroke.Open AccessReactive Exercises with Interactive Objects: Interim Analysis of a Randomized Trial on Task-Driven NMES Grasp Rehabilitation for Subacute and Early Chronic Stroke Patients
Enriched environments and tools are believed to promote grasp rehabilitation after stroke. We designed S2, an interactive grasp rehabilitation system consisting of smart objects, custom orthoses for selective grasp constraining, and an electrode array system for forearm NMES. Motor improvements and perceived usability of a new enriched upper limb training system for sub-acute stroke patients was assessed in this interim analysis. Inclusion criteria: sub-acute stroke patients with , ipsilesional , and contralesional . Effects of 30-min therapy supplements, conventional vs. S2 prototype, are compared through a parallel two-arms dose-matched open-label trial, lasting 27 sessions. Clinical centres: Asklepios Neurologische Klinik Falkenstein, Königstein im Taunus, Germany, and Clinica Villa Beretta, Costa Masnaga, Italy. Assessment scales: ARAT, System Usability, and Technology Acceptance. Methodology: 26 participants were block randomized, allocated to the study (control , experimental ) and underwent the training protocol. Among them, 11 participants with ARAT score at inclusion below 35, n = 6 in the experimental group, and n = 5 in the control group were analysed. Results: participants in the enriched treatment group displayed a larger improvement in the ARAT scale (+14.9 pts, ). Perceived usability differed between clinics. No adverse effect was observed in relation to the treatments. Trial status: closed. Conclusions: The S2 system, developed according to shared clinical directives, was tested in a clinical proof of concept. Variations of ARAT scores confirm the feasibility of clinical investigation for hand rehabilitation after stroke. - Open Access
- 5 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (12) , 3290-3300
A Hybrid Robotic System for Arm Training of Stroke Survivors: Concept and First Evaluation
Objective: To develop and evaluate a hybrid robotic system for arm recovery after stroke, combining EMG-triggered Functional Electrical Stimulation (FES) with a passive exoskeleton for upper limb suspension. Methods: The system was used in a structured exercise program resembling activities of daily life. Exercises execution was continuously controlled using angle sensor data and Radio-Frequency IDentification (RFID) technology. The training program consisted of 27 sessions lasting 30 minutes each. Seven post-acute stroke patients were recruited from two clinical sites. The efficacy of the system was evaluated in terms of Action Research Arm Test, Motricity Index, Motor Activity Log, and Box & Blocks tests. Furthermore, kinematics-based and EMG-based outcome measures were derived directly from data collected during training sessions. Results: All patients showed an improvement of motor functions at the end of the training program. After training, the exercises were in most cases executed faster, smoother and with an increased range of motion. Subjects were able to trigger FES, but in some cases, they did not maintain the voluntary effort during task execution. All subjects but one considered the system usable. Conclusion: The preliminary results showed that the system can be used in a clinical environment with positive effects on arm functional recovery. However, only the final results of the currently ongoing clinical trial will unveil the system full potential. Significance: The presented hybrid robotic system is highly customizable, allows to monitor the daily performance, requires low supervision of the therapist and might have the potential to enhance arm recovery after stroke.
- 5 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (12) , 3290-3300
Open AccessA Hybrid Robotic System for Arm Training of Stroke Survivors: Concept and First Evaluation
Objective: To develop and evaluate a hybrid robotic system for arm recovery after stroke, combining EMG-triggered Functional Electrical Stimulation (FES) with a passive exoskeleton for upper limb suspension. Methods: The system was used in a structured exercise program resembling activities of daily life. Exercises execution was continuously controlled using angle sensor data and Radio-Frequency IDentification (RFID) technology. The training program consisted of 27 sessions lasting 30 minutes each. Seven post-acute stroke patients were recruited from two clinical sites. The efficacy of the system was evaluated in terms of Action Research Arm Test, Motricity Index, Motor Activity Log, and Box & Blocks tests. Furthermore, kinematics-based and EMG-based outcome measures were derived directly from data collected during training sessions. Results: All patients showed an improvement of motor functions at the end of the training program. After training, the exercises were in most cases executed faster, smoother and with an increased range of motion. Subjects were able to trigger FES, but in some cases, they did not maintain the voluntary effort during task execution. All subjects but one considered the system usable. Conclusion: The preliminary results showed that the system can be used in a clinical environment with positive effects on arm functional recovery. However, only the final results of the currently ongoing clinical trial will unveil the system full potential. Significance: The presented hybrid robotic system is highly customizable, allows to monitor the daily performance, requires low supervision of the therapist and might have the potential to enhance arm recovery after stroke.
- Open Access
- 26 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 1 (2) , 106-114
Patient Motion Using a Computerized Leg Brace in Everyday Locomotion Tasks
Exoskeletal systems are becoming a rehabilitation standard of care for persons with lower limb paralysis. As muscular dysfunctions affect a heterogeneous patient group, each individual develops their own strategy to negotiate everyday locomotion challenges. This paper introduces a microprocessor controlled orthotic system that passively supports people with lower limb paralyses in their everyday locomotion tasks while incorporating the user as the highest control entity. A clinical study with seven patients with a range of leg pareses investigated the functionality and usage of the system while capturing the mechanical stress on the device. Data from the knee joint was recorded in locomotion tasks including level walking, ramp and stair negotiation. For all patients the measurements demonstrate that the motion for level walking was close to the motion of healthy individuals. In other tasks, variations between the patients were large with respect to motion kinematics, power and torque requirements. As the control concept supported individualized motion patterns, patients perceived the system functionality as intuitive. The mechanically most demanding task was stair descent with a peak torque of 1.47 Nm/kg and peak dissipative power up to 2.67 W/kg. Intra-subject variability makes prediction of movements and loads challenging.
- 26 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 1 (2) , 106-114
Open AccessPatient Motion Using a Computerized Leg Brace in Everyday Locomotion Tasks
Exoskeletal systems are becoming a rehabilitation standard of care for persons with lower limb paralysis. As muscular dysfunctions affect a heterogeneous patient group, each individual develops their own strategy to negotiate everyday locomotion challenges. This paper introduces a microprocessor controlled orthotic system that passively supports people with lower limb paralyses in their everyday locomotion tasks while incorporating the user as the highest control entity. A clinical study with seven patients with a range of leg pareses investigated the functionality and usage of the system while capturing the mechanical stress on the device. Data from the knee joint was recorded in locomotion tasks including level walking, ramp and stair negotiation. For all patients the measurements demonstrate that the motion for level walking was close to the motion of healthy individuals. In other tasks, variations between the patients were large with respect to motion kinematics, power and torque requirements. As the control concept supported individualized motion patterns, patients perceived the system functionality as intuitive. The mechanically most demanding task was stair descent with a peak torque of 1.47 Nm/kg and peak dissipative power up to 2.67 W/kg. Intra-subject variability makes prediction of movements and loads challenging.
- Open Access
Ultra-Low-Power Digital Filtering for Insulated EMG Sensing
Myoelectric prostheses help amputees to regain independence and a higher quality of life. These prostheses are controlled by state-of-the-art electromyography sensors, which use a conductive connection to the skin and are therefore sensitive to sweat. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Here, we present ultra-low-power digital signal processing algorithms for an insulated EMG sensor which couples the EMG signal capacitively. These sensors require neither conductive connection to the skin nor electrolytic paste or skin preparation. Capacitive sensors allow straightforward application. However, they make a sophisticated signal amplification and noise suppression necessary. A low-cost sensor has been developed for real-time myoelectric prostheses control. The major hurdles in measuring the EMG are movement artifacts and external noise. We designed various digital filters to attenuate this noise. Optimal system setup and filter parameters for the trade-off between attenuation of this noise and sufficient EMG signal power for high signal quality were investigated. Additionally, an algorithm for movement artifact suppression, enabling robust application in real-world environments, is presented. The algorithms, which require minimal calculation resources and memory, are implemented on an ultra-low-power microcontroller.
Open AccessUltra-Low-Power Digital Filtering for Insulated EMG Sensing
Myoelectric prostheses help amputees to regain independence and a higher quality of life. These prostheses are controlled by state-of-the-art electromyography sensors, which use a conductive connection to the skin and are therefore sensitive to sweat. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Here, we present ultra-low-power digital signal processing algorithms for an insulated EMG sensor which couples the EMG signal capacitively. These sensors require neither conductive connection to the skin nor electrolytic paste or skin preparation. Capacitive sensors allow straightforward application. However, they make a sophisticated signal amplification and noise suppression necessary. A low-cost sensor has been developed for real-time myoelectric prostheses control. The major hurdles in measuring the EMG are movement artifacts and external noise. We designed various digital filters to attenuate this noise. Optimal system setup and filter parameters for the trade-off between attenuation of this noise and sufficient EMG signal power for high signal quality were investigated. Additionally, an algorithm for movement artifact suppression, enabling robust application in real-world environments, is presented. The algorithms, which require minimal calculation resources and memory, are implemented on an ultra-low-power microcontroller.
- Open Access
An Insulated Flexible Sensor for Stable Electromyography Detection: Application to Prosthesis Control
Electromyography (EMG), the measurement of electrical muscle activity, is used in a variety of applications, including myoelectric upper-limb prostheses, which help amputees to regain independence and a higher quality of life. The state-of-the-art sensors in prostheses have a conductive connection to the skin and are therefore sensitive to sweat and require preparation of the skin. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Due to their insulating layer between skin and sensor area, capacitive sensors are insensitive to the skin condition, they require neither conductive connection to the skin nor electrolytic paste or skin preparation. Here, we describe a highly stable, low-power capacitive EMG measurement set-up that is suitable for real-world application. Various flexible multi-layer sensor set-ups made of copper and insulating foils, flex print and textiles were compared. These flexible sensor set-ups adapt to the anatomy of the human forearm, therefore they provide high wearing comfort and ensure stability against motion artifacts. The influence of the materials used in the sensor set-up on the magnitude of the coupled signal was demonstrated based on both theoretical analysis and measurement.The amplifier circuit was optimized for high signal quality, low power consumption and mobile application. Different shielding and guarding concepts were compared, leading to high SNR.
Open AccessAn Insulated Flexible Sensor for Stable Electromyography Detection: Application to Prosthesis Control
Electromyography (EMG), the measurement of electrical muscle activity, is used in a variety of applications, including myoelectric upper-limb prostheses, which help amputees to regain independence and a higher quality of life. The state-of-the-art sensors in prostheses have a conductive connection to the skin and are therefore sensitive to sweat and require preparation of the skin. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Due to their insulating layer between skin and sensor area, capacitive sensors are insensitive to the skin condition, they require neither conductive connection to the skin nor electrolytic paste or skin preparation. Here, we describe a highly stable, low-power capacitive EMG measurement set-up that is suitable for real-world application. Various flexible multi-layer sensor set-ups made of copper and insulating foils, flex print and textiles were compared. These flexible sensor set-ups adapt to the anatomy of the human forearm, therefore they provide high wearing comfort and ensure stability against motion artifacts. The influence of the materials used in the sensor set-up on the magnitude of the coupled signal was demonstrated based on both theoretical analysis and measurement.The amplifier circuit was optimized for high signal quality, low power consumption and mobile application. Different shielding and guarding concepts were compared, leading to high SNR.
- 16 October 2018
- Published by Springer Nature
- p. 8-11
The Role of Industry in a H2020 Innovation Action – Transferring Research into Products
- 16 October 2018
- Published by Springer Nature
- p. 8-11
The Role of Industry in a H2020 Innovation Action – Transferring Research into Products
- 1 January 2014
- Published by Springer Nature
- p. 51-59
Fully Implantable Multichannel EMG Measurement System: First Results
- 1 January 2014
- Published by Springer Nature
- p. 51-59
Fully Implantable Multichannel EMG Measurement System: First Results