Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sabine Bauer has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    HealthWalk: Promoting Health and Mobility through Sensor-Based Rollator Walker Assistance

    by Ivanna Kramer, Kevin Weirauch, Sabine Bauer, Mark Oliver Mints, Peer Neubert

    Rollator walkers allow people with physical limitations to increase their mobility and give them the confidence and independence to participate in society for longer. However, rollator walker users often have poor posture, leading to further health problems and, in the worst case, falls. Integrating sensors into rollator walker designs can help to address this problem and results in a platform that allows several other interesting use cases. This paper briefly overviews existing systems and the current research directions and challenges in this field. We also present our early HealthWalk rollator walker prototype for data collection with older people, rheumatism, multiple sclerosis and Parkinson patients, and individuals with visual impairments.


  • Open Access

    Analysis of Adolescents’ Head to Shoulder Region during Tablet Use from Sagittal and Frontal RGB Images

    by Ivanna Kramer, Sabine Bauer

    As schools go digital, the use of tablet computers is increasing. Concerns are raised that the extensive use of tablets and the associated bent-over posture may negatively affect the individual’s health. In order to analyse the possible effects of prolonged tablet use on physical health, a detailed analysis of the posture during tablet use is needed so that appropriate preventive measures can be taken to prevent degenerative changes. Therefore, the aim of this study was to measure and report the posture of 56 students while working with a tablet computer and compare it with an upright posture. Sagittal and frontal images were used for measurements of the subjects’ postures while seated, using the tablet, and in a neutral sitting position looking straight ahead. The body position during tablet use was recorded in two different user configurations: tablet flat on the table and tablet in individual freely chosen user configuration. After appropriate annotation of the data, the following parameters were evaluated in different planes. The craniovertebral angle (CVA), head tilt angle (HTA), and forward shoulder angle (FSA) are measurements that describe the extent to which the head bends forward and downward and how the shoulders are aligned in the sagittal plane. On the other hand, the head shoulder angle (HSA), lateral head tilt angle (LHTA), and trunk flexion angle (TFA) are angles measured in the frontal plane, which indicate the degree of head tilt and trunk bending to the right or left side. The measurement results clearly showed that the use of a tablet had a pronounced effect on the positions and rotations of the participants’ head, neck, and shoulders. This was evident through strong deviations observed in the angles measured between the sitting straight posture and the postures while using the tablet. For example, depending on the body posture class, the mean CVA values were 45.76° for straight sitting posture, 28.25° for holding the tablet individually posture, and 26.04° for the posture adopted while using a tablet placed flat on the table.

  • Open Access

    A Simple, Efficient Method for an Automatic Adjustment of the Lumbar Curvature Alignment in an MBS Model of the Spine

    by Ivanna Kramer, Sabine Bauer, Valentin Keppler

    In many fields of spinal health care, efforts have been made to offer individualized products and therapy tailored to the patient. Therefore, the prevailing alignment of the spine must be considered, which varies from person to person and depends on the movement and loading situation. With the help of patient-specific simulation models of the spine, the geometrical parameters in a specific body position can be analyzed, and the load situation of the spinal structures during dynamic processes can be assessed. However, to enable the future usability of such simulation models in medical reality, as many patient-specific conditions as possible need to be considered. Another critical requirement is that simulation models must be quickly and easily created for use in clinical routine. Building new or adapting existing spine multibody simulation (MBS) models is time-consuming due to their complex structure. To overcome this limitation, we developed a simple, efficient method by which to automatically adjust the lumbar curvature orientation of the spine model. The method extracts a new 3D lordosis curve from patient-specific data in the preprocessing step. Then the vertebrae and all linked spinal structures of an existing spinal simulation model are transformed so that the lumbar lordosis follows the curve obtained in the first part of the method. To validate the proposed approach, three independent experts measured the Cobb angle in the source and the generated spine alignments. We calculated a mean absolute error of 1.29° between the generated samples and the corresponded ground truth. Furthermore, the minor deviation in the root mean square error (RMSE) of 0.0012 m2 between the areas under the alignment curves in the original and target lordosis curvatures indicated the accuracy of the proposed method. The proposed method demonstrated that a new patient-specific simulation model can be generated in a short time from any suitable data source.


  • Open Access

    Automated Detection of Ear Tragus and C7 Spinous Process in a Single RGB Image—A Novel Effective Approach

    by Ivanna Kramer, Sabine Bauer, Anne Matejcek

    Biophotogrammetric methods for postural analysis have shown effectiveness in the clinical practice because they do not expose individuals to radiation. Furthermore, valid statements can be made about postural weaknesses. Usually, such measurements are collected via markers attached to the subject’s body, which can provide conclusions about the current posture. The craniovertebral angle (CVA) is one of the recognized measurements used for the analysis of human head–neck postures. This study presents a novel method to automate the detection of the landmarks that are required to determine the CVA in RGBs. Different image processing methods are applied together with a neuronal network Openpose to find significant landmarks in a photograph. A prominent key body point is the spinous process of the cervical vertebra C7, which is often visible on the skin. Another visual landmark needed for the calculation of the CVA is the ear tragus. The methods proposed for the automated detection of the C7 spinous process and ear tragus are described and evaluated using a custom dataset. The results indicate the reliability of the proposed detection approach, particularly head postures.


  • Open Access

    Can a Priori Unknown Values of Biomechanical Parameters Be Determined with Sufficient Accuracy in MBS Using Sensitivity Analysis? Analyzing the Characteristics of the Interaction between Cervical Vertebra and Pedicle Screw

    by Ivanna Kramer, Sabine Bauer

    Finite element (FE) modeling is a commonly used method to investigate the influence of medical devices, such as implants and screws, on the biomechanical behavior of the spine. Another simulation method is multibody simulation (MBS), where the model is composed of several non-deformable bodies. MBS solvers generally require a very short computing time for dynamic tasks, compared with an FE analysis. Considering this computational advantage, in this study, we examine whether parameters for which values are not known a priori can be determined with sufficient accuracy using an MBS model. Therefore, we propose a many-at-a-time sensitivity analysis method that allows us to approximate these a priori unknown parameters without requiring long simulation times. This method enables a high degree of MBS model optimization to be achieved in an iterative process. The sensitivity analysis method was applied to a simplified screw–vertebra model, consisting of an anterior anchor implant screw and vertebral body of C4. An experiment described in the literature was used as the basis for developing and assessing the potential of the method for sensitivity analyses and for validating the model’s action. The optimal model parameters for the MBS model were determined to be c = 823,224 N/m for stiffness and d = 488 Ns/m for damping. The presented method of parameter identification can be used in studies including more complex MBS spine models or to set initial parameter values that are not available as initial values for FE models.


  • Open Access

    Can a Priori Unknown Values of Biomechanical Parameters Be Determined with Sufficient Accuracy in Mbs Using Sensitivity Analysis? Analyzing the Interaction Characteristics between Cervical Vertebra and Pedicle Screw

    by Ivanna Kramer, Sabine Bauer

    Finite element (FE) modeling is commonly used as a method to investigate the influence of medical devices, such as implants and screws and their effects on the biomechanical behavior of the spine. Another simulation method is a multi-body simulation (MBS), where the model is composed of several non-deformable bodies. MBS solvers generally require a very short computing time for dynamic tasks compared to an FE analysis. Considering this computational advantage, in this study, we examine whether parameters whose values are not known a priory can be determined with sufficient accuracy using MBS model. Therefore, we propose a Many-at-a-time sensitivity analysis method that allows approximating these a priory unknown parameters without requiring long simulation times. This method enables a high degree of MBS model optimization to be achieved in an iterative process. The sensitivity analysis method is applied to a simplified screw-vertebra model, consisting of an anterior anchor implant screw and vertebral body of C4. An experiment described in the literature is used as a basis for developing and assessing the potential of the method for sensitivity analysis and to validate the models action. The optimal model parameters for the MBS model were determined to be c=823224N/m for stiffness and d=488Ns/m for damping. The presented method of parameter identification can be used in studies including more complex MBS spine models or to set initial parameter values that are not available as initial values for FE models.

  • Open Access

    Parameter Dependencies of a Biomechanical Cervical Spine FSU - The Process of Finding Optimal Model Parameters by Sensitivity Analysis

    by Sabine Bauer, Ivanna Kramer

    The knowledge about the impact of structure-specific parameters on the biomechanical behavior of a computer model has an essential meaning for the realistic modeling and system improving. Especially the biomechanical parameters of the intervertebral discs, the ligamentous structures and the facet joints are seen in the literature as significant components of a spine model, which define the quality of the model. Therefore, it is important to understand how the variations of input parameters for these components affect the entire model and its individual structures. Sensitivity analysis can be used to gain the required knowledge about the correlation of the input and output variables in a complex spinal model. The present study analyses the influence of the biomechanical parameters of the intervertebral disc using different sensitivity analysis methods to optimize the spine model parameters. The analysis is performed with a multi-body simulation model of the cervical functional spinal unit C6-C7.


  • Visualization of Human Spine Biomechanics for Spinal Surgery

    by Pepe Eulzer, Sabine Bauer, Francis Kilian, Kai Lawonn

    We propose a visualization application, designed for the exploration of human spine simulation data. Our goal is to support research in biomechanical spine simulation and advance efforts to implement simulation-backed analysis in surgical applications. Biomechanical simulation is a state-of-the-art technique for analyzing load distributions of spinal structures. Through the inclusion of patient-specific data, such simulations may facilitate personalized treatment and customized surgical interventions. Difficulties in spine modelling and simulation can be partly attributed to poor result representation, which may also be a hindrance when introducing such techniques into a clinical environment. Comparisons of measurements across multiple similar anatomical structures and the integration of temporal data make commonly available diagrams and charts insufficient for an intuitive and systematic display of results. Therefore, we facilitate methods such as multiple coordinated views, abstraction and focus and context to display simulation outcomes in a dedicated tool. By linking the result data with patient-specific anatomy, we make relevant parameters tangible for clinicians. Furthermore, we introduce new concepts to show the directions of impact force vectors, which were not accessible before. We integrated our toolset into a spine segmentation and simulation pipeline and evaluated our methods with both surgeons and biomechanical researchers. When comparing our methods against standard representations that are currently in use, we found increases in accuracy and speed in data exploration tasks. In a qualitative review, domain experts deemed the tool highly useful when dealing with simulation result data, which typically combines time-dependent patient movement and the resulting force distributions on spinal structures.


  • Open Access

    Computational Simulation as an Innovative Approach in Personalized Medicine

    by Bauer Sabine, Paulus Dietrich

    Statistical analyses show that both the spine curvature and the morphological properties of the vertebral bodies can differ considerably. Therefore, the best outcome of a surgery for the individual patient could be achieved by developing patient specific implants to prevent inadequate anchorage of implants that don?t optimally fit to the anatomy and can cause damages of spinal structures.