    In-Vivo Evaluation of Microultrasound and Thermometric Capsule Endoscopes

    by Holly S. Lay, Marc P. Y. Desmulliez, Sandy Cochran, Gerard Cummins, Benjamin F. Cox, Yongqiang Qiu, Mihnea Vlad Turcanu, Rachael McPhillips, Ciaran Connor, Rachael Gregson, et al.

    Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a non-invasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (μUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of μUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of μUS B-scans and safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and μUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature μUS systems.


  • Open Access

    In Vivo Characterization of a Wireless Telemetry Module for a Capsule Endoscopy System Utilizing a Conformal Antenna

    by Julia Faerber, Rachael Gregson, Richard Eddie Clutton, Sadeque Reza Khan, Sandy Cochran, Marc P. Y. Desmulliez, Gerard Cummins, Sumanth Kumar Pavuluri, Paul Record, Adrian R. Ayastuy Rodriguez, et al.

    This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a $\text{10\,mm\,}\times \,\text{30\,mm}$ capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of –10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10−3 packet error rate and 10−5 bit error rate and no temperature increase of the tissue according to IEEE standards.


  • Open Access

    Acoustic Sensing and Ultrasonic Drug Delivery in Multimodal Theranostic Capsule Endoscopy

    by Fraser R. Stewart, Yongqiang Qiu, Holly S. Lay, Ian P. Newton, Benjamin F. Cox, Mohammed A. Al-Rawhani, James Beeley, Yangminghao Liu, Zhihong Huang, David R. S. Cumming, et al.

    Video capsule endoscopy (VCE) is now a clinically accepted diagnostic modality in which miniaturized technology, an on-board power supply and wireless telemetry stand as technological foundations for other capsule endoscopy (CE) devices. However, VCE does not provide therapeutic functionality, and research towards therapeutic CE (TCE) has been limited. In this paper, a route towards viable TCE is proposed, based on multiple CE devices including important acoustic sensing and drug delivery components. In this approach, an initial multimodal diagnostic device with high-frequency quantitative microultrasound that complements video imaging allows surface and subsurface visualization and computer-assisted diagnosis. Using focused ultrasound (US) to mark sites of pathology with exogenous fluorescent agents permits follow-up with another device to provide therapy. This is based on an US-mediated targeted drug delivery system with fluorescence imaging guidance. An additional device may then be utilized for treatment verification and monitoring, exploiting the minimally invasive nature of CE. While such a theranostic patient pathway for gastrointestinal treatment is presently incomplete, the description in this paper of previous research and work under way to realize further components for the proposed pathway suggests it is feasible and provides a framework around which to structure further work.


  • Ultrasound capsule endoscopy: sounding out the future

    by Benjamin F. Cox, Fraser Stewart, Holly Lay, Gerard Cummins Cummins, Ian P. Newton, Marc P. Y. Desmulliez, Robert J. C. Steele, Inke Näthke, Sandy Cochran

    Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently.


  • High Resolution Microultrasound (μUS) Investigation of the Gastrointestinal (GI) Tract

    by Thineskrishna Anbarasan, Christine E. M. Démoré, Holly Lay, Mohammed R. S. Sunoqrot, Romans Poltarjonoks, Sandy Cochran, Benjamin F. Cox

    High resolution, microultrasound (μUS) scanning of the gastrointestinal (GI) tract has potential as an important transmural imaging modality to aid in diagnosis. Operating at higher frequencies than conventional clinical ultrasound instruments, μUS is capable of providing scanned images of the GI tract with higher resolution. To investigate the use of μUS for this application, a phantom which is cost effective, within ethical guidelines and, most importantly, similar in histology to the human GI tract is necessary. Therefore, a phantom utilizing porcine small bowel tissue has been developed for custom assembled μUS scanning systems. Two such systems, a stepping scanner and a continuous sweep scanner were utilized to repeatedly scan regions of prepared samples of porcine small bowel tissue. The porcine small bowel tissue phantom was perfused with degassed phosphate buffer saline (dPBS) solution through a cannula inserted in its mesenteric vessel to simulate in vivo conditions and achieve better μUS mucosal characterization. The μUS system scans a transducer across the tissue phantom to acquire RF echo data, which is then processed using MATLAB. A B-scan reconstruction produces 2D images with relative echo strength mapped to a color map of the user’s choice. The phantom developed also allows for modifications such as the insertion of fiducial markers to detect tissue change over time and simultaneous perfusion and scanning, providing a platform for more detailed research and investigation into μUS scanning of the GI tract.


  • Quantitative microultrasound characterization of gastrointestinal tissue for ultrasound capsule endoscopy

    by Holly Lay, Benjamin F. Cox, Christine E. Demore, Gabriel C. Spalding, Sandy Cochran

    Gastrointestinal (GI) disease progression is often characterized by cellular and architectural changes within the mucosal and sub-mucosal layers. One relevant disorder, Barrett’s esophagus, is of particular interest as a recognized predictor of esophageal cancer. To enhance the clinical ability to detect cellular changes deeper in tissue and earlier, we are exploring quantitative microultrasound) techniques in healthy ex vivo porcine GI tissue for implementation in ultrasound capsule endoscopy. A single-element, piezocomposite mUS transducer operating at fc = 47.7 MHz was used to obtain pulse-echo images of ex vivo porcine gastroesophageal samples, which were bisected and mechanically scanned along the long GI axis. Selected samples were mechanically separated to isolate the upper mucosal layers from the underlying muscle layers and placed on a known agar substrate to calculate the attenuation coefficient of the tissue. All other sample data were digitally segmented. Reflectivity data from the top 50, 100, and 250 μm of tissue were analysed to assess the effect of variable surface density on the calculated acoustic impedance. The entire thickness of the segmented tissue was then used to calculate position-dependent backscatter coefficient (BSC) along with intra- and inter-sample variability for use as a baseline from which to make further quantitative advances.