Thorsten Goettsche
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thorsten Goettsche has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Frank
Institut fr Mikroelektronik (IMS CHIPS), Stuttgart, Germany
1 shared publication - Anna Woitok
Institute for Laboratory Animal Science, RWTH Aachen University, Aachen, Germany
1 shared publication Bart Kootte
Osypka AG, Rheinfelden, Germany
1 shared publicationEckardt Bihler
DYCONEXMST AG, Bassersdorf, Switzerland
1 shared publication- Jean Schleipen
Philips Research, Eindhoven, The Netherlands
1 shared publication - Jens Anders
University of Stuttgart
1 shared publication
Latest Publications
- 4 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (1) , 76-88
A 97-Channel Read-Out ASIC for an Electrophysiological Mapping Catheter With an Optical Link
Electrophysiological (EP) mapping catheters are medical equipment, which are widely used to diagnose and treat atrial fibrillation. The electrophysiology signals are sensed by the catheter's electrodes, for which a large electrode count becomes more and more essential because of the demand for a higher local resolution. A drawback of the large electrode count is the effort to pass through and to integrate the wires inside the catheter shaft. To overcome with this issue, this article describes the realization of an EP ASIC, which is placed close to the 97 electrodes and to perform an in-tip digitization. Thanks to an integrated optical link, only a single fiber is required to connect the catheter tip to an externally located electro-optical unit and thus shrinking the shaft volume to a minimum. The fiber is used to guide light from the electro-optical unit to the catheter tip and illuminate a blue LED, which is located close to the EP ASIC and acts as a photovoltaic cell. The EP ASIC is designed to use the LED as power source and a data transceiver while performing signal conditioning and digitization of the EP signals at the same time. The EP signals are captured with the ASIC's multi-channel read-out circuit consisting of 97 fully differential preamplifiers and additional filter stages. A switch network sequentially selects one single channel for further amplification and digitization of the EP signal. The read-out circuit is designed to process signals in the range of 500 μVpp to 20 mVpp with a bandwidth of 5 Hz to 100 Hz.
- 4 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (1) , 76-88
A 97-Channel Read-Out ASIC for an Electrophysiological Mapping Catheter With an Optical Link
Electrophysiological (EP) mapping catheters are medical equipment, which are widely used to diagnose and treat atrial fibrillation. The electrophysiology signals are sensed by the catheter's electrodes, for which a large electrode count becomes more and more essential because of the demand for a higher local resolution. A drawback of the large electrode count is the effort to pass through and to integrate the wires inside the catheter shaft. To overcome with this issue, this article describes the realization of an EP ASIC, which is placed close to the 97 electrodes and to perform an in-tip digitization. Thanks to an integrated optical link, only a single fiber is required to connect the catheter tip to an externally located electro-optical unit and thus shrinking the shaft volume to a minimum. The fiber is used to guide light from the electro-optical unit to the catheter tip and illuminate a blue LED, which is located close to the EP ASIC and acts as a photovoltaic cell. The EP ASIC is designed to use the LED as power source and a data transceiver while performing signal conditioning and digitization of the EP signals at the same time. The EP signals are captured with the ASIC's multi-channel read-out circuit consisting of 97 fully differential preamplifiers and additional filter stages. A switch network sequentially selects one single channel for further amplification and digitization of the EP signal. The read-out circuit is designed to process signals in the range of 500 μVpp to 20 mVpp with a bandwidth of 5 Hz to 100 Hz.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 123-126
DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects
Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 123-126
Open AccessDRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects
Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.
- 6 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (SI-1 Track) , 1009
Results from long-term In-vivo Tests of a Wireless, Intravascular Blood-Pressure Monitoring System for Hypertension Patients
- 6 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (SI-1 Track) , 1009
Results from long-term In-vivo Tests of a Wireless, Intravascular Blood-Pressure Monitoring System for Hypertension Patients
- 1 September 2008
- Vol. 19 (5) , 23-5
New diagnostics with wireless pressure monitoring.
Hypertonia and heart failures have become two of the main diseases affecting today's human population. A telemetric controlled sensor implant without a battery is being developed and evaluated with in vivo experiments for use as a powerful tool in long-term post surgical evaluation of heart pressure, body temperature and pulse rate. Its capabilities are reported here.
- 1 September 2008
- Vol. 19 (5) , 23-5
New diagnostics with wireless pressure monitoring.
Hypertonia and heart failures have become two of the main diseases affecting today's human population. A telemetric controlled sensor implant without a battery is being developed and evaluated with in vivo experiments for use as a powerful tool in long-term post surgical evaluation of heart pressure, body temperature and pulse rate. Its capabilities are reported here.