  • A 97-Channel Read-Out ASIC for an Electrophysiological Mapping Catheter With an Optical Link

    by Alexander Frank, Bart Kootte, Thorsten Göttsche, Peter Jutte, Jean Schleipen, Paul Dijkstra, Eckardt Bihler, Joachim N. Burghartz, Jens Anders

    Electrophysiological (EP) mapping catheters are medical equipment, which are widely used to diagnose and treat atrial fibrillation. The electrophysiology signals are sensed by the catheter's electrodes, for which a large electrode count becomes more and more essential because of the demand for a higher local resolution. A drawback of the large electrode count is the effort to pass through and to integrate the wires inside the catheter shaft. To overcome with this issue, this article describes the realization of an EP ASIC, which is placed close to the 97 electrodes and to perform an in-tip digitization. Thanks to an integrated optical link, only a single fiber is required to connect the catheter tip to an externally located electro-optical unit and thus shrinking the shaft volume to a minimum. The fiber is used to guide light from the electro-optical unit to the catheter tip and illuminate a blue LED, which is located close to the EP ASIC and acts as a photovoltaic cell. The EP ASIC is designed to use the LED as power source and a data transceiver while performing signal conditioning and digitization of the EP signals at the same time. The EP signals are captured with the ASIC's multi-channel read-out circuit consisting of 97 fully differential preamplifiers and additional filter stages. A switch network sequentially selects one single channel for further amplification and digitization of the EP signal. The read-out circuit is designed to process signals in the range of 500 μVpp to 20 mVpp with a bandwidth of 5 Hz to 100 Hz.


  • Open Access

    DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects

    by Roland Fischer, Jens Weidenmüller, Michael Görtz, Thorsten Goettsche, Wilfried Mokwa

    Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.

  • Results from long-term In-vivo Tests of a Wireless, Intravascular Blood-Pressure Monitoring System for Hypertension Patients

    by N. J. Cleven, A. Woitok, T. Penzkofer, P. Isfort, M. Görtz, T. Goettsche, U. Steinseifer, T. Schmitz-Rode

    • 1 September 2008
      • Vol. 19  (5) , 23-5

    New diagnostics with wireless pressure monitoring.

    by Thorsten Goettsche, Maik Graefe, P Osypka

    Hypertonia and heart failures have become two of the main diseases affecting today's human population. A telemetric controlled sensor implant without a battery is being developed and evaluated with in vivo experiments for use as a powerful tool in long-term post surgical evaluation of heart pressure, body temperature and pulse rate. Its capabilities are reported here.