Tino Morgenstern
Tino Morgenstern has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Richter
University of Applied Sciences HRW , Institute for measurement and sensor technologies , Duisburger Straße 100 , Mülheim an der Ruhr , Germany
1 shared publication - Dinan Wang
University of Applied Sciences HRW , Institute of Energy System and Energy Economics Technology , Lützowstraße 5 , Bottrop , Germany
1 shared publication - Dirk Rueter
Institute of Measurement Engineering and Sensor Technology, University of Applied Sciences Ruhr West, D-45407 Mülheim an der Ruhr, Germany
1 shared publication - Jörg Himmel
Institute for Measurement Engineering and Sensor Technology, Ruhr West University of Applied Sciences, 45479 Mülheim an der Ruhr, Germany
1 shared publication - Olfa Kanoun
Measurement and Sensor Technology, Chemnitz University of Technology, Chemnitz, Germany
1 shared publication - Stephan Klöckner
Olympus Surgical Technologies Europe , Kuehnstraße 61 , Hamburg , Germany
1 shared publication
Latest Publications
- Open Access
- 10 January 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (7-8) , 459-469
Finite volume analysis of the temperature distribution during transurethral resection of the prostate
In prostate surgery the transurethral resection (TURP) represents the gold standard which is based on monopolar (M-TURP) and bipolar techniques (TURis). The investigation of the thermal behavior is one of the most important research topics in this type of surgery procedures. Here monopolar systems have been well investigated. The research on electrical and thermal behavior of bipolar systems was initiated about two decades ago. Previous studies focused on thermal behavior according to Joule heating, but did not gain information about the temperature distribution close to the active electrode of the resectoscope. Therefore, the numerical simulations on the temperature distribution near the active electrode of the resectoscope with a finite volume method are presented in this study, which takes blood perfusion into account. The results have shown that the influence of the blood perfusion process can be ignored for regions which are more than 0.4 mm away from the active electrode. This is based on two different blood perfusion models.
- 10 January 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (7-8) , 459-469
Open AccessFinite volume analysis of the temperature distribution during transurethral resection of the prostate
In prostate surgery the transurethral resection (TURP) represents the gold standard which is based on monopolar (M-TURP) and bipolar techniques (TURis). The investigation of the thermal behavior is one of the most important research topics in this type of surgery procedures. Here monopolar systems have been well investigated. The research on electrical and thermal behavior of bipolar systems was initiated about two decades ago. Previous studies focused on thermal behavior according to Joule heating, but did not gain information about the temperature distribution close to the active electrode of the resectoscope. Therefore, the numerical simulations on the temperature distribution near the active electrode of the resectoscope with a finite volume method are presented in this study, which takes blood perfusion into account. The results have shown that the influence of the blood perfusion process can be ignored for regions which are more than 0.4 mm away from the active electrode. This is based on two different blood perfusion models.
- Open Access
- 1 December 2014
- Published by Elsevier in Ultrasonics
- Vol. 54 (8) , 2141-2150
Ultrasound generation with high power and coil only EMAT concepts
- 1 December 2014
- Published by Elsevier in Ultrasonics
- Vol. 54 (8) , 2141-2150
Open AccessUltrasound generation with high power and coil only EMAT concepts