Ting Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ting Liu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- James Yang
Department of Civil and Architectural Engineering, KTH Royal Institute of Technology, Stockholm 10044, Sweden
3 shared publications - Andrea Bottacin-Busolin
Department of Industrial Engineering, University of PADOVA, Italy
1 shared publication - Chang Lin
Department of Civil Engineering, National Chung Hsing University, Taichung 40227, Taiwan
1 shared publication
Latest Publications
- 6 June 2014
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 52 (4) , 523-531
Effects of intake-entrance profiles on free-surface vortices
Intake free-surface vortices can cause efficiency losses, flow fluctuations and even structural damages. Experiments were performed to examine the effect of entrance shapes on the critical submergence. Seven entrance shapes were devised and tested, including a square-edged, a bell-mouthed, three symmetrical conical and two conical profiles with eccentricity. The focus of the study was on a range of Froude numbers from 0.25 to 0.65. The square-edged shape appeared to show the highest local head-loss compared to other shapes. Steady counter-clockwise vortices characterize all the intake profiles except in a narrow water tank. The experiments show both discrepancy and similarity between the intake profiles. The critical submergence of the bell-mouthed intake is lower when compared to the square-edged shape. For the other profiles, it is proportional to the Froude number. A closer sidewall may lead to larger critical submergence in the case of weak circulations. The results demonstrate that the intake-entrance profile has an important effect on the critical submergence.
- 6 June 2014
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 52 (4) , 523-531
Effects of intake-entrance profiles on free-surface vortices
Intake free-surface vortices can cause efficiency losses, flow fluctuations and even structural damages. Experiments were performed to examine the effect of entrance shapes on the critical submergence. Seven entrance shapes were devised and tested, including a square-edged, a bell-mouthed, three symmetrical conical and two conical profiles with eccentricity. The focus of the study was on a range of Froude numbers from 0.25 to 0.65. The square-edged shape appeared to show the highest local head-loss compared to other shapes. Steady counter-clockwise vortices characterize all the intake profiles except in a narrow water tank. The experiments show both discrepancy and similarity between the intake profiles. The critical submergence of the bell-mouthed intake is lower when compared to the square-edged shape. For the other profiles, it is proportional to the Froude number. A closer sidewall may lead to larger critical submergence in the case of weak circulations. The results demonstrate that the intake-entrance profile has an important effect on the critical submergence.
- Open Access
- 1 January 2014
- Published by Taylor & Francis in Engineering Applications of Computational Fluid Mechanics
- Vol. 8 (1) , 104-115
Three-dimensional Computations of Water–Air Flow in a Bottom Spillway During Gate Opening
Undesired entrainment of air in a bottom spillway often leads to problems in both safety and operational functions. A numerical analysis of a transient process of air entrainment into bottom spillway flows when a spillway gate is opened was conducted in this study. The Volume of Fluid (VOF) model was used. The 3D computational domain consisted of a spillway conduit, a moving bulkhead gate, a gate shaft, an upstream reservoir and a downstream outlet. The large number of cells, together with the dynamic mesh modelling of the moving gate, required substantial computational resources, which necessitated parallel computing on a mainframe computer. The simulations captured the changes in the flow patterns and predicted the amount of air entrainment in the gate shaft and the detrainment downstream, which help in the understanding of the system behaviour during opening of the spillway gate. The initial conduit water level and the gate opening procedure affect the degree of air entrainment in the gate shaft. To release the undesired air, a de-aeration chamber with a tube leading to the atmosphere was added to the conduit. Despite the incomplete air release, the de-aeration chamber was found to be effective in reducing water surface fluctuations in the downstream outlet.
- 1 January 2014
- Published by Taylor & Francis in Engineering Applications of Computational Fluid Mechanics
- Vol. 8 (1) , 104-115
Open AccessThree-dimensional Computations of Water–Air Flow in a Bottom Spillway During Gate Opening
Undesired entrainment of air in a bottom spillway often leads to problems in both safety and operational functions. A numerical analysis of a transient process of air entrainment into bottom spillway flows when a spillway gate is opened was conducted in this study. The Volume of Fluid (VOF) model was used. The 3D computational domain consisted of a spillway conduit, a moving bulkhead gate, a gate shaft, an upstream reservoir and a downstream outlet. The large number of cells, together with the dynamic mesh modelling of the moving gate, required substantial computational resources, which necessitated parallel computing on a mainframe computer. The simulations captured the changes in the flow patterns and predicted the amount of air entrainment in the gate shaft and the detrainment downstream, which help in the understanding of the system behaviour during opening of the spillway gate. The initial conduit water level and the gate opening procedure affect the degree of air entrainment in the gate shaft. To release the undesired air, a de-aeration chamber with a tube leading to the atmosphere was added to the conduit. Despite the incomplete air release, the de-aeration chamber was found to be effective in reducing water surface fluctuations in the downstream outlet.
- 5 March 2013
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 51 (3) , 265-272
Experimental studies of air pocket movement in a pressurized spillway conduit
Undesired air entrainment in a bottom outlet conduit causes pressure transients, leading to conduit vibrations, blowbacks and discharge pulsations and thus endangers operational safety. In this study, the propagation velocity of a solitary air pocket and the characteristics of its critical velocity were examined in experiments conducted using a 240-mm-diameter pipe. Air pocket movement depends on the pipe diameter, slope, roughness and air pocket size. The critical pipe Froude number for initiating downstream movement of an air pocket is smaller in a larger pipe, most likely due to the scale effect and/or to a smaller reduction in the effective cross-sectional area. The critical velocity in rough pipes was found to be independent of the air pocket size. A minimum Froude number was suggested for a rough pipe instead of a critical pipe Froude number because the air removal process was found to involve successive air losses from the air pocket caused by turbulence.
- 5 March 2013
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 51 (3) , 265-272
Experimental studies of air pocket movement in a pressurized spillway conduit
Undesired air entrainment in a bottom outlet conduit causes pressure transients, leading to conduit vibrations, blowbacks and discharge pulsations and thus endangers operational safety. In this study, the propagation velocity of a solitary air pocket and the characteristics of its critical velocity were examined in experiments conducted using a 240-mm-diameter pipe. Air pocket movement depends on the pipe diameter, slope, roughness and air pocket size. The critical pipe Froude number for initiating downstream movement of an air pocket is smaller in a larger pipe, most likely due to the scale effect and/or to a smaller reduction in the effective cross-sectional area. The critical velocity in rough pipes was found to be independent of the air pocket size. A minimum Froude number was suggested for a rough pipe instead of a critical pipe Froude number because the air removal process was found to involve successive air losses from the air pocket caused by turbulence.