Lakhan Singh Titare
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lakhan Singh Titare has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Pushpendra Singh
Indian Institute of Technology Ropar
5 shared publications - L. D. Arya
Shri Govindram Seksaria Institute of Technology and Science
4 shared publications - Pankaj Kumar Sharma
Department of Electrical & Electronics Engineering, UIT-RGPV, Bhopal, MP 462036, India
3 shared publications - Sharat Chandra Choube
Department of Electrical & Electronics Engineering, UIT-RGPV, Bhopal, MP 462036, India
3 shared publications - Pradeep Purey
Department of Electronic Engineering, Maharaja Ranjit Singh College of Professional Sciences, Indore, India
2 shared publications - Rajesh Arya
Department of Information Technology, Acropolis Institute of Technology and Research, Indore, India
2 shared publications
Latest Publications
- Open Access
Multi-Objective Optimal Location of Distributed Generators & Capacitor Banks into Radial Distribution Network by Novel Metaheuristic Optimisation
The integration of renewable-based distributed units into distributed systems has been aided by recently developed technologies based on renewable energy, changes to utility infrastructure, and progressive government regulations. In this paper, an improved version of the golden jackal optimization (IGJO) is implemented to incorporate distributed generators (DGs) and capacitor banks (CBs) into the distribution system. The existing studies give only DG unit insertion, but in this work, simultaneous integration of different kinds of DG with a capacitor bank is used to analyze the impact. The main emphasis of this study is to minimize power loss along with the upgradation of the voltage profile. Improvement in voltage stability index and minimization of total voltage deviation (TVD) were also achieved by placing the DG and CB units in a suitable position. Load modeling is also considered here to validate the results. Seven types of loading, including constant power (half load and heavy load), constant current, constant impedance, residential, industrial, and commercial loads, are used to show the effect of integration of DG and capacitor bank into a 33-bus and 118-bus radial distribution system. Comparison of the proposed method with previous studies shows the better performance of the implemented method over other techniques.
Open AccessMulti-Objective Optimal Location of Distributed Generators & Capacitor Banks into Radial Distribution Network by Novel Metaheuristic Optimisation
The integration of renewable-based distributed units into distributed systems has been aided by recently developed technologies based on renewable energy, changes to utility infrastructure, and progressive government regulations. In this paper, an improved version of the golden jackal optimization (IGJO) is implemented to incorporate distributed generators (DGs) and capacitor banks (CBs) into the distribution system. The existing studies give only DG unit insertion, but in this work, simultaneous integration of different kinds of DG with a capacitor bank is used to analyze the impact. The main emphasis of this study is to minimize power loss along with the upgradation of the voltage profile. Improvement in voltage stability index and minimization of total voltage deviation (TVD) were also achieved by placing the DG and CB units in a suitable position. Load modeling is also considered here to validate the results. Seven types of loading, including constant power (half load and heavy load), constant current, constant impedance, residential, industrial, and commercial loads, are used to show the effect of integration of DG and capacitor bank into a 33-bus and 118-bus radial distribution system. Comparison of the proposed method with previous studies shows the better performance of the implemented method over other techniques.
- 14 January 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (2)
Sag and harmonics control for solar PV system integrated to grid using Crosslink Harmonizer Integrator
This paper described a novel strategy for mitigation of voltage sag and harmonic using Crosslink Harmonizer Integrator (CHI) filter for solar PV system integration to grid. The proposed system, based on a double-stage 3-phase topology, addresses the challenges of ensuring power quality during abnormal grid conditions while enhancing the operational versatility of the PV system. Under typical operating circumstances, no reactive power is sent to the grid; instead, power is delivered to the grid at a Unity Power Factor (UPF). However, during grid voltage variations, the control technique dynamically adjusts the voltage at the Point of Common Coupling (PCC) to maintain it within specified limits. This is achieved by injecting or absorbing reactive power as needed. The Voltage Source Converter (VSC) and DC link capacitor work as a Distributed Static Synchronous Compensator (DSTATCOM) to optimize system use at times when PV generation does not occur, such as at night. However, this method preserves power quality far better than conventional control methods. MATLAB simulation is used to confirm the effectiveness of the proposed control mechanism. Both simulation and hardware implementation (OPAL-RT OP4510 real time simulator) are used for illustrating the control's achievements.
- 14 January 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (2)
Sag and harmonics control for solar PV system integrated to grid using Crosslink Harmonizer Integrator
This paper described a novel strategy for mitigation of voltage sag and harmonic using Crosslink Harmonizer Integrator (CHI) filter for solar PV system integration to grid. The proposed system, based on a double-stage 3-phase topology, addresses the challenges of ensuring power quality during abnormal grid conditions while enhancing the operational versatility of the PV system. Under typical operating circumstances, no reactive power is sent to the grid; instead, power is delivered to the grid at a Unity Power Factor (UPF). However, during grid voltage variations, the control technique dynamically adjusts the voltage at the Point of Common Coupling (PCC) to maintain it within specified limits. This is achieved by injecting or absorbing reactive power as needed. The Voltage Source Converter (VSC) and DC link capacitor work as a Distributed Static Synchronous Compensator (DSTATCOM) to optimize system use at times when PV generation does not occur, such as at night. However, this method preserves power quality far better than conventional control methods. MATLAB simulation is used to confirm the effectiveness of the proposed control mechanism. Both simulation and hardware implementation (OPAL-RT OP4510 real time simulator) are used for illustrating the control's achievements.
- Open Access
Enhancement of Power Quality in Photovoltaic Systems for Weak Grid Connections
This paper proposes a novel control strategy for a dual-stage grid-connected solar photovoltaic (PV) system designed to ensure reliable and efficient operation under unstable grid conditions. The strategy incorporates a Phase-Locked Loop (PLL)-based positive sequence estimator for accurate detection of grid voltage disturbances, including sags, swells, and fluctuations in solar irradiance. A dynamic DC-link voltage regulation mechanism is employed to minimize converter power losses and enhance the performance of the Voltage Source Converter (VSC) under weak grid scenarios. The control scheme maintains continuous maximum power point tracking (MPPT) and unity power factor (UPF) operation, thereby improving overall grid power quality. The proposed method is validated through comprehensive simulations and real-time hardware implementation using the OPAL-RT OP4510 platform. The results demonstrate compliance with IEEE Standard 519, confirming the effectiveness and robustness of the proposed strategy.
Open AccessEnhancement of Power Quality in Photovoltaic Systems for Weak Grid Connections
This paper proposes a novel control strategy for a dual-stage grid-connected solar photovoltaic (PV) system designed to ensure reliable and efficient operation under unstable grid conditions. The strategy incorporates a Phase-Locked Loop (PLL)-based positive sequence estimator for accurate detection of grid voltage disturbances, including sags, swells, and fluctuations in solar irradiance. A dynamic DC-link voltage regulation mechanism is employed to minimize converter power losses and enhance the performance of the Voltage Source Converter (VSC) under weak grid scenarios. The control scheme maintains continuous maximum power point tracking (MPPT) and unity power factor (UPF) operation, thereby improving overall grid power quality. The proposed method is validated through comprehensive simulations and real-time hardware implementation using the OPAL-RT OP4510 platform. The results demonstrate compliance with IEEE Standard 519, confirming the effectiveness and robustness of the proposed strategy.
- Open Access
- 20 May 2024
- Published by Springer Nature in Research Square
Under Voltage Control approach using CHI for Solar PV Integration in Grid
The primary focus in managing voltage source converters (VSC) integrated with the grid during abnormal conditions lies in maintaining both voltage stability and power quality. This study introduces a novel control approach tailored for regulating solar photovoltaic (PV) systems connected to the grid using a Crosslink Harmonizer Integrator (CHI) Filter. The system adopts a double-stage three-phase topology. Its core objective is to ensure continuous power transmission from the PV system to the grid, even under diverse abnormal grid circumstances. Under normal operating conditions, power is supplied to the grid with a unity power factor (UPF). However, in the face of grid voltage fluctuations, the control scheme adjusts the Point of Common Coupling (PCC) voltage within specified limits by injecting reactive power. To maximize system utilization during periods of no PV generation, such as night time, the VSC and DC link capacitor serve as a Distribution Static Compensator (DSTATCOM). Notably, this approach maintains power quality without sacrificing traditional control techniques. The efficacy of the proposed control methodology is verified through MATLAB simulation. Furthermore, a comparative analysis against state-of-the-art techniques underscores the effectiveness of the proposed control strategy.
- 20 May 2024
- Published by Springer Nature in Research Square
Open AccessUnder Voltage Control approach using CHI for Solar PV Integration in Grid
The primary focus in managing voltage source converters (VSC) integrated with the grid during abnormal conditions lies in maintaining both voltage stability and power quality. This study introduces a novel control approach tailored for regulating solar photovoltaic (PV) systems connected to the grid using a Crosslink Harmonizer Integrator (CHI) Filter. The system adopts a double-stage three-phase topology. Its core objective is to ensure continuous power transmission from the PV system to the grid, even under diverse abnormal grid circumstances. Under normal operating conditions, power is supplied to the grid with a unity power factor (UPF). However, in the face of grid voltage fluctuations, the control scheme adjusts the Point of Common Coupling (PCC) voltage within specified limits by injecting reactive power. To maximize system utilization during periods of no PV generation, such as night time, the VSC and DC link capacitor serve as a Distribution Static Compensator (DSTATCOM). Notably, this approach maintains power quality without sacrificing traditional control techniques. The efficacy of the proposed control methodology is verified through MATLAB simulation. Furthermore, a comparative analysis against state-of-the-art techniques underscores the effectiveness of the proposed control strategy.
- 13 March 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (2) , 1425-1452
Emergency load shedding to maintain line flows in presence of WTDFIG using modified crow search algorithm
- 13 March 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (2) , 1425-1452
Emergency load shedding to maintain line flows in presence of WTDFIG using modified crow search algorithm
- 19 October 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 104 (6) , 1185-1196
A Novel Technique of Ranking of Transmission Lines for Maintenance Prioritization Accounting Annual Outage Time and Operational Severities
- 19 October 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 104 (6) , 1185-1196
A Novel Technique of Ranking of Transmission Lines for Maintenance Prioritization Accounting Annual Outage Time and Operational Severities
- 9 July 2014
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 95 (4) , 337-343
Genetic Algorithm Used for Load Shedding Based on Sensitivity to Enhance Voltage Stability
- 9 July 2014
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 95 (4) , 337-343
Genetic Algorithm Used for Load Shedding Based on Sensitivity to Enhance Voltage Stability
- 30 September 2009
- Published by Elsevier in Applied Soft Computing
- Vol. 9 (4) , 1197-1207
An approach to mitigate the risk of voltage collapse accounting uncertainties using improved particle swarm optimization
- 30 September 2009
- Published by Elsevier in Applied Soft Computing
- Vol. 9 (4) , 1197-1207
An approach to mitigate the risk of voltage collapse accounting uncertainties using improved particle swarm optimization
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 431-434
Adequacy assessment of composite system based on static voltage stability limit using ANN
A new methodology has been developed for determining probability of failure accounting static voltage stability limits under various network and generation capacity states. These failure probabilities have been obtained for various total systems loading condition. Corrective capabilities under various system states have been accounted via an optimization formulation. Results so obtained have been used to train a multilayer feed forward network. Hence probability of failure can be calculated on-line. The algorithm has been implemented on 6-bus, 7-line test system.
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 431-434
Adequacy assessment of composite system based on static voltage stability limit using ANN
A new methodology has been developed for determining probability of failure accounting static voltage stability limits under various network and generation capacity states. These failure probabilities have been obtained for various total systems loading condition. Corrective capabilities under various system states have been accounted via an optimization formulation. Results so obtained have been used to train a multilayer feed forward network. Hence probability of failure can be calculated on-line. The algorithm has been implemented on 6-bus, 7-line test system.