Xin Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xin Xing has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Chao Yang
4 shared publicationsHaiying Dai
Department of Plastic Surgery, Changhai Hospital, Second Military Medical University, Shanghai, PR China
3 shared publicationsMiao Xu
Department of Plastic and Reconstructive Surgery, Xinhua Hospital, Shanghai Jiao Tong University, Shanghai 200092, China
3 shared publicationsShuo Fang
Department of Plastic and Reconstruction, Shanghai Changhai Hospital Affiliated to Navy Medical University, 168th Chang Hai Road, Shanghai, People's Republic of China
3 shared publications- Shuo Fang
Department of Plastic Surgery
3 shared publications - Guangdong Zhou
Department of Plastic and Reconstructive Surgery Shanghai Ninth People's Hospital Shanghai Key Laboratory of Tissue Engineering Shanghai Jiao Tong University School of Medicine Shanghai P. R. China
2 shared publications
Latest Publications
- 1 December 2019
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 72 (12) , 2017-2026
Anatomical study of the extraocular check ligament system
- 1 December 2019
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 72 (12) , 2017-2026
Anatomical study of the extraocular check ligament system
- 1 May 2019
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 72 (5) , 848-862
A novel modification of keystone flap for superficial defects repair
- 1 May 2019
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 72 (5) , 848-862
A novel modification of keystone flap for superficial defects repair
- Open Access
- 11 August 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (8) , e0182971
Experimental study of ASCs combined with POC-PLA patch for the reconstruction of full-thickness chest wall defects
To explore the repairing effect of combination of adipose stem cells (ASCs) and composite scaffolds on CWR, the electrospun Poly 1, 8-octanediol-co-citric acid (POC)-poly-L-lactide acid (PLA) composite scaffolds were prepared, followed by in vitro and in vivo biocompatibility evaluation of the scaffolds. Afterwards, ASCs were seeded on POC-PLA to construct the POC-PLA-ASCs scaffolds, and the POC-PLA, POC-PLA-ASCs, and traditional materials expanded polytetrafluoroethylene (ePTFE) were adopt for CWR in New Zealand white (NZW) rabbit models. As results, the POC-PLA-ASCs patches possessed good biocompatibility as the high proliferation ability of cells surrounding the patches. Rabbits in POC-PLA-ASCs groups showed better pulmonary function, less pleural adhesion, higher degradation rate and more neovascularization when compared with that in other two groups. The results of western blot indicated that POC-PLA-ASCs patches accelerated the expression of VEGF and Collagen I in rabbit models. From the above, our present study demonstrated that POC-PLA material was applied for CWR successfully, and ASCs seeded on the sheets could improve the pleural adhesions and promote the reparation of chest wall defects.
- 11 August 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (8) , e0182971
Open AccessExperimental study of ASCs combined with POC-PLA patch for the reconstruction of full-thickness chest wall defects
To explore the repairing effect of combination of adipose stem cells (ASCs) and composite scaffolds on CWR, the electrospun Poly 1, 8-octanediol-co-citric acid (POC)-poly-L-lactide acid (PLA) composite scaffolds were prepared, followed by in vitro and in vivo biocompatibility evaluation of the scaffolds. Afterwards, ASCs were seeded on POC-PLA to construct the POC-PLA-ASCs scaffolds, and the POC-PLA, POC-PLA-ASCs, and traditional materials expanded polytetrafluoroethylene (ePTFE) were adopt for CWR in New Zealand white (NZW) rabbit models. As results, the POC-PLA-ASCs patches possessed good biocompatibility as the high proliferation ability of cells surrounding the patches. Rabbits in POC-PLA-ASCs groups showed better pulmonary function, less pleural adhesion, higher degradation rate and more neovascularization when compared with that in other two groups. The results of western blot indicated that POC-PLA-ASCs patches accelerated the expression of VEGF and Collagen I in rabbit models. From the above, our present study demonstrated that POC-PLA material was applied for CWR successfully, and ASCs seeded on the sheets could improve the pleural adhesions and promote the reparation of chest wall defects.
- Open Access
- 1 January 2016
- Published by Wolters Kluwer Health in Medicine
- Vol. 95 (2) , e2505
The Use of Composite Flaps in the Management of Large Full-Thickness Defects of the Lower Eyelid
To describe a modified surgical procedure that uses a combination of the tarsoconjunctival flap, orbicularis myocutaneous advancement flap, and paranasal-island flap to correct extensive full-thickness lower eyelid defects in functioning eyes. From May 2010 to December 2013, a total of 15 patients had reconstructive surgeries of large to giant lower eyelid defect, with an average 19-month follow-up. The musculocutaneous flaps were harvested from both orbicularis and paranasal regions and clinical outcomes were recorded and analyzed. No major complications were observed in any of the patients. All the patients showed aesthetic eyelid contour, good color, and texture match as well as no obvious scar formation. The mean Marginal Reflex Distance-2 measured 4 months after surgery was 4.9 ± 0.4 mm. Reconstruction of a large defect in the lower eyelid with a tarsoconjunctival flap and the composite neighboring musculocutaneous flaps is a reliable and reproducible method. With proper design and well-executed precision, excellent functional and aesthetic results can be achieved by this elegant procedure without any major complications.
- 1 January 2016
- Published by Wolters Kluwer Health in Medicine
- Vol. 95 (2) , e2505
Open AccessThe Use of Composite Flaps in the Management of Large Full-Thickness Defects of the Lower Eyelid
To describe a modified surgical procedure that uses a combination of the tarsoconjunctival flap, orbicularis myocutaneous advancement flap, and paranasal-island flap to correct extensive full-thickness lower eyelid defects in functioning eyes. From May 2010 to December 2013, a total of 15 patients had reconstructive surgeries of large to giant lower eyelid defect, with an average 19-month follow-up. The musculocutaneous flaps were harvested from both orbicularis and paranasal regions and clinical outcomes were recorded and analyzed. No major complications were observed in any of the patients. All the patients showed aesthetic eyelid contour, good color, and texture match as well as no obvious scar formation. The mean Marginal Reflex Distance-2 measured 4 months after surgery was 4.9 ± 0.4 mm. Reconstruction of a large defect in the lower eyelid with a tarsoconjunctival flap and the composite neighboring musculocutaneous flaps is a reliable and reproducible method. With proper design and well-executed precision, excellent functional and aesthetic results can be achieved by this elegant procedure without any major complications.
- 24 July 2015
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 68 (11) , 1516-1521
An “oxhorn”-shaped V–Y advancement flap unilaterally pedicled on a nasal superficial musculoaponeurotic system for nasal reconstruction
- 24 July 2015
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 68 (11) , 1516-1521
An “oxhorn”-shaped V–Y advancement flap unilaterally pedicled on a nasal superficial musculoaponeurotic system for nasal reconstruction
- 1 March 2015
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 68 (3) , 403-409
Ultrasound-guided scraping of fibrous capsule plus bilayered negative pressure wound therapy for treatment of refractory postmastectomy seroma
- 1 March 2015
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 68 (3) , 403-409
Ultrasound-guided scraping of fibrous capsule plus bilayered negative pressure wound therapy for treatment of refractory postmastectomy seroma
- 1 November 2014
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 67 (11) , 1508-1514
Reconstruction of the zygomatic cheek defects using a flap based on the pretragal perforator of the superficial temporal artery
- 1 November 2014
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 67 (11) , 1508-1514
Reconstruction of the zygomatic cheek defects using a flap based on the pretragal perforator of the superficial temporal artery
- 2 October 2014
- Published by Springer Nature in Tissue Engineering and Regenerative Medicine
- Vol. 11 (5) , 379-386
Proliferated Leydig cells for engineered testis-like tissue regeneration with testosterone-secreting ability
- 2 October 2014
- Published by Springer Nature in Tissue Engineering and Regenerative Medicine
- Vol. 11 (5) , 379-386
Proliferated Leydig cells for engineered testis-like tissue regeneration with testosterone-secreting ability
- 1 January 2014
- Vol. 30 (1) , 10-3
[The keystone design perforator island flap in reconstructive surgery].
To introduce the experience in skin defects reconstruction using keystone design perforator island flap. Since June 2012 to June 2013, the flaps have been used in 14 patients. The size of defects ranged from 1 cm x 1 cm to 5 cm x 9 cm at the extremities, trunk and facial region. The trapezoidal shaped flap has the same width as the defect. The flap is designed along the edge of the defect with 90 degree angle at the ends of the island flap. This curvilinear- and trapezoidal-shaped flap essentially consists of two conjoined V-Y advancement flaps at the proximal and distal end. The vascular supply is supported by the subcutaneous vascular network and fascial/muscular perforators. Perforators should be detected by Doppler techniques when large size flaps are used. Primary wound healing and satisfactory result was achieved in 13 patients except for one with partial flap necrosis. The technique offers a simple and effective method of wound closure in situations that would otherwise have required complex flap closure or skin grafting.
- 1 January 2014
- Vol. 30 (1) , 10-3
[The keystone design perforator island flap in reconstructive surgery].
To introduce the experience in skin defects reconstruction using keystone design perforator island flap. Since June 2012 to June 2013, the flaps have been used in 14 patients. The size of defects ranged from 1 cm x 1 cm to 5 cm x 9 cm at the extremities, trunk and facial region. The trapezoidal shaped flap has the same width as the defect. The flap is designed along the edge of the defect with 90 degree angle at the ends of the island flap. This curvilinear- and trapezoidal-shaped flap essentially consists of two conjoined V-Y advancement flaps at the proximal and distal end. The vascular supply is supported by the subcutaneous vascular network and fascial/muscular perforators. Perforators should be detected by Doppler techniques when large size flaps are used. Primary wound healing and satisfactory result was achieved in 13 patients except for one with partial flap necrosis. The technique offers a simple and effective method of wound closure in situations that would otherwise have required complex flap closure or skin grafting.
- 1 January 2014
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 35 (3) , 291
Hemostatic efficacies of mesoporous materials HW and microporous materials ZSM-5?a comparative study
:Objective To compare the hemostatic efficacies and exothermic reactions between mesoporous and microporous materials with similar components but different specific surface areas and pore sizes, so as to lay a foundation for developing new first-aid hemostat with mesoporous materials. Methods Totally 15 male pigs were made into femoral artery fatal hemorrhage models and were randomly divided into three average groups (group A, group B and group C). Their hemostatic efficacies and exothermic reactions on the tissues were compared between the three groups (group A was treated with hemostatic mesoporous material HW, group B with microporous material ZSM-5, and group C with standard gauze as control). Results The hemostatic time periods of group A and B were (49.50±3.27) s and (59.50±2.42) s, respectively (PPConclusion Compared to mesoporous material HW, the microporous material ZSM-5 has more rapid hemostatic efficacies and slighter exothermic reaction, and ZSM-5 is a promising carrier for next generation first-aid hemostatic study.
- 1 January 2014
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 35 (3) , 291
Hemostatic efficacies of mesoporous materials HW and microporous materials ZSM-5?a comparative study
:Objective To compare the hemostatic efficacies and exothermic reactions between mesoporous and microporous materials with similar components but different specific surface areas and pore sizes, so as to lay a foundation for developing new first-aid hemostat with mesoporous materials. Methods Totally 15 male pigs were made into femoral artery fatal hemorrhage models and were randomly divided into three average groups (group A, group B and group C). Their hemostatic efficacies and exothermic reactions on the tissues were compared between the three groups (group A was treated with hemostatic mesoporous material HW, group B with microporous material ZSM-5, and group C with standard gauze as control). Results The hemostatic time periods of group A and B were (49.50±3.27) s and (59.50±2.42) s, respectively (PPConclusion Compared to mesoporous material HW, the microporous material ZSM-5 has more rapid hemostatic efficacies and slighter exothermic reaction, and ZSM-5 is a promising carrier for next generation first-aid hemostatic study.