Young Il Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Young Il Kim has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Jong Jun Park
4 shared publications- Sung Won Kim
Department of Architectural Engineering, Graduate School, Seoul National University of Science & Technology, Seoul 01811, Republic of Korea
3 shared publications - Yeo-Kyung Lee
Department of Architectural Engineering, Graduate School, Seoul National University of Science and Technology, Seoul 01811, Korea
3 shared publications - A. Young Nam
Graduate School of Energy and Environment, Seoul National University of Science & Technology, Seoul, South Korea
2 shared publications - Arisae Nam
Department of Architectural Engineering, Graduate School, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea
1 shared publication - Duhwan Lee
Department of Architectural Engineering, Graduate School, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 34  (1)
Internal flow path improvement for pressure loss reduction in heat recovery ventilation system using CFD
Energy-recovery ventilators (ERV) exhaust polluted indoor air while supplying outdoor fresh air and recovering energy via heat and mass exchange. Their adoption is rapidly increasing because they simultaneously improve indoor air quality and reduce building energy consumption. This study quantifies the pressure-loss contribution of a sliding bypass damper’s gear-support bracket located in the ERV damper space of a 350 m³/h unit comprising a desiccant rotor and heat-pump dehumidification. We employ steady, incompressible RANS CFD(Reynolds averaged Navier-Stokes computational fluid dynamics) using the realizable $$\:k-\epsilon\:\:$$ turbulence model and an experiment-based porous-media method. Four internal flow paths are analyzed: OA(Outdoor air) to EA(Exhaust air), OA to SA(Supply air), RA(Return air) to EA, and RA to SA. To reduce computational cost, the section from the OA/RA inlets to the heat-exchanger face, rotor/fan rotation, and thermal effects are excluded from the domain. The fin-tube heat exchanger and desiccant rotor are modeled as porous media; their viscous and inertial resistances are inferred from dedicated fin-tube pressure-drop tests and manufacturer data and were used to validate the CFD model. Removing the damper gear-support yields the largest benefit in the OA to SA path: at 450 m³/h the total pressure drop decreases by 11.9%. In RA to EA, however, improving inlet-face flow uniformity is identified as a more effective strategy than bracket removal. For OA to EA and RA to SA, the effect of bracket removal is marginal. Across all paths, net pressure-drop reductions of 1.78%, 4.61%, and 4.77% are obtained at 250, 350, and 450 m³/h, respectively. Based on these findings, we suggest replacing the sliding bypass damper (or redesigning its support) and pursuing additional loss-reduction measures such as inlet-face flow conditioning and inlet/outlet alignment. The results demonstrate that CFD, coupled with experiment-informed porous-media modeling, is an effective tool for guiding low-cost internal-flow improvements that reduce ERV pressure losses.- 23 June 2026
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 34  (1)
Open AccessInternal flow path improvement for pressure loss reduction in heat recovery ventilation system using CFD
Energy-recovery ventilators (ERV) exhaust polluted indoor air while supplying outdoor fresh air and recovering energy via heat and mass exchange. Their adoption is rapidly increasing because they simultaneously improve indoor air quality and reduce building energy consumption. This study quantifies the pressure-loss contribution of a sliding bypass damper’s gear-support bracket located in the ERV damper space of a 350 m³/h unit comprising a desiccant rotor and heat-pump dehumidification. We employ steady, incompressible RANS CFD(Reynolds averaged Navier-Stokes computational fluid dynamics) using the realizable $$\:k-\epsilon\:\:$$ turbulence model and an experiment-based porous-media method. Four internal flow paths are analyzed: OA(Outdoor air) to EA(Exhaust air), OA to SA(Supply air), RA(Return air) to EA, and RA to SA. To reduce computational cost, the section from the OA/RA inlets to the heat-exchanger face, rotor/fan rotation, and thermal effects are excluded from the domain. The fin-tube heat exchanger and desiccant rotor are modeled as porous media; their viscous and inertial resistances are inferred from dedicated fin-tube pressure-drop tests and manufacturer data and were used to validate the CFD model. Removing the damper gear-support yields the largest benefit in the OA to SA path: at 450 m³/h the total pressure drop decreases by 11.9%. In RA to EA, however, improving inlet-face flow uniformity is identified as a more effective strategy than bracket removal. For OA to EA and RA to SA, the effect of bracket removal is marginal. Across all paths, net pressure-drop reductions of 1.78%, 4.61%, and 4.77% are obtained at 250, 350, and 450 m³/h, respectively. Based on these findings, we suggest replacing the sliding bypass damper (or redesigning its support) and pursuing additional loss-reduction measures such as inlet-face flow conditioning and inlet/outlet alignment. The results demonstrate that CFD, coupled with experiment-informed porous-media modeling, is an effective tool for guiding low-cost internal-flow improvements that reduce ERV pressure losses. - Open Access
Recovery and Utilization of Flash Steam from Rotary Desiccant Regeneration in Dry Room HVAC Systems
Dry rooms used in battery and semiconductor research facilities require ultra-low dew-point environments, which demand significant thermal energy for desiccant rotor regeneration. In steam-regenerated systems, condensate discharged through steam traps partially evaporates due to pressure reduction, generating flash steam that is typically released into the atmosphere, resulting in substantial energy losses. This study investigates the generation and recovery potential of flash steam in dry room HVAC systems. Field measurements were conducted for 18 steam-regenerated desiccant air handling units installed in a medium-scale research facility (total floor area: 43,000 m2) in southern Gyeonggi Province, Korea. Boiler operation data—including feedwater flow rate, pressure, and operating time—were analyzed over a six-month period from March to August 2025. The results showed that the average flash steam generation rate was approximately 1.16 ton/h, corresponding to 8.56% of the average feedwater flow rate. Two recovery methods were evaluated: a steam jet thermocompressor (SJT) and an exhaust vapor condenser (EVC). The analysis revealed that the EVC system provides a more practical solution for medium-scale dry rooms because it does not require high-pressure primary steam. By recovering flash steam using three EVC units, an average heat recovery of 724 kW was achieved. The recovered heat can produce 86 °C hot water, which can be utilized as a driving heat source for an absorption chiller, generating approximately 507 kW of cooling capacity. This configuration partially offsets the cooling load of existing centrifugal chillers, thereby reducing electrical energy consumption. In addition, the proposed system eliminates atmospheric discharge of flash steam, mitigating the visible white plume phenomenon commonly observed in industrial facilities. The results demonstrate the technical feasibility of integrating flash steam recovery with absorption cooling to enhance energy efficiency in medium-scale dry room HVAC systems.
Open AccessRecovery and Utilization of Flash Steam from Rotary Desiccant Regeneration in Dry Room HVAC Systems
Dry rooms used in battery and semiconductor research facilities require ultra-low dew-point environments, which demand significant thermal energy for desiccant rotor regeneration. In steam-regenerated systems, condensate discharged through steam traps partially evaporates due to pressure reduction, generating flash steam that is typically released into the atmosphere, resulting in substantial energy losses. This study investigates the generation and recovery potential of flash steam in dry room HVAC systems. Field measurements were conducted for 18 steam-regenerated desiccant air handling units installed in a medium-scale research facility (total floor area: 43,000 m2) in southern Gyeonggi Province, Korea. Boiler operation data—including feedwater flow rate, pressure, and operating time—were analyzed over a six-month period from March to August 2025. The results showed that the average flash steam generation rate was approximately 1.16 ton/h, corresponding to 8.56% of the average feedwater flow rate. Two recovery methods were evaluated: a steam jet thermocompressor (SJT) and an exhaust vapor condenser (EVC). The analysis revealed that the EVC system provides a more practical solution for medium-scale dry rooms because it does not require high-pressure primary steam. By recovering flash steam using three EVC units, an average heat recovery of 724 kW was achieved. The recovered heat can produce 86 °C hot water, which can be utilized as a driving heat source for an absorption chiller, generating approximately 507 kW of cooling capacity. This configuration partially offsets the cooling load of existing centrifugal chillers, thereby reducing electrical energy consumption. In addition, the proposed system eliminates atmospheric discharge of flash steam, mitigating the visible white plume phenomenon commonly observed in industrial facilities. The results demonstrate the technical feasibility of integrating flash steam recovery with absorption cooling to enhance energy efficiency in medium-scale dry room HVAC systems.
- Open Access
Performance Prediction of a Vertical Downward Supply Direct Expansion Cooling System for Large Spaces Through Field Experiments
Performance prediction of an air-cooled direct expansion (DX) vertical downward-supply cooling system applied to large spaces is a key element for achieving efficient control and energy savings. Recent studies have predominantly relied on complex artificial intelligence (AI)-based or high-dimensional models that require a large number of input variables to achieve high predictive accuracy. In contrast, limited research has focused on developing simple, interpretable, and practically applicable models based on field-measured data. To address this gap, the present study proposes a physically grounded multiple linear regression model with a minimal number of variables, which can be implemented in practice using only three standard sensors: indoor air temperature, outdoor air temperature, and airflow rate. Field data were refined through physical criteria derived from ASHRAE standards (steady-state operation and removal of outliers) and by identifying steady-state ranges using the Kernel Density Estimation (KDE) method. A total of 133,718 valid samples were used for analysis. The proposed model achieved a coefficient of determination (R2) of 0.93, a root mean square error (RMSE) of 2.86 kW, and mean absolute error (MAE) of 2.31 kW, corresponding to approximately ±6% deviation from measured cooling capacity. These results satisfy the typical accuracy criteria in the HVAC field (R2 > 0.9, error < 10%) and confirm high predictive reliability despite the model’s simplicity. The achieved accuracy implies that the proposed model can be extended to field-level performance prediction and energy-efficient operation. Comparison with second-order polynomial and nonlinear (1/Tout) models showed only marginal improvement in accuracy. Consequently, the proposed three-variable regression model introduces a practical framework for performance prediction and control of DX-type cooling systems that integrates simplicity, physical interpretability, and field applicability.
Open AccessPerformance Prediction of a Vertical Downward Supply Direct Expansion Cooling System for Large Spaces Through Field Experiments
Performance prediction of an air-cooled direct expansion (DX) vertical downward-supply cooling system applied to large spaces is a key element for achieving efficient control and energy savings. Recent studies have predominantly relied on complex artificial intelligence (AI)-based or high-dimensional models that require a large number of input variables to achieve high predictive accuracy. In contrast, limited research has focused on developing simple, interpretable, and practically applicable models based on field-measured data. To address this gap, the present study proposes a physically grounded multiple linear regression model with a minimal number of variables, which can be implemented in practice using only three standard sensors: indoor air temperature, outdoor air temperature, and airflow rate. Field data were refined through physical criteria derived from ASHRAE standards (steady-state operation and removal of outliers) and by identifying steady-state ranges using the Kernel Density Estimation (KDE) method. A total of 133,718 valid samples were used for analysis. The proposed model achieved a coefficient of determination (R2) of 0.93, a root mean square error (RMSE) of 2.86 kW, and mean absolute error (MAE) of 2.31 kW, corresponding to approximately ±6% deviation from measured cooling capacity. These results satisfy the typical accuracy criteria in the HVAC field (R2 > 0.9, error < 10%) and confirm high predictive reliability despite the model’s simplicity. The achieved accuracy implies that the proposed model can be extended to field-level performance prediction and energy-efficient operation. Comparison with second-order polynomial and nonlinear (1/Tout) models showed only marginal improvement in accuracy. Consequently, the proposed three-variable regression model introduces a practical framework for performance prediction and control of DX-type cooling systems that integrates simplicity, physical interpretability, and field applicability.
- Open Access
- 25 October 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 76
Hybrid TRRM–deep learning approach for water-cooled centrifugal chiller COP prediction
- 25 October 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 76
Open AccessHybrid TRRM–deep learning approach for water-cooled centrifugal chiller COP prediction
- Open Access
- 28 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17  (11) , 4961
Sustainable Natural Ventilation Strategies for Acceptable Indoor Air Quality: An Experimental and Simulated Study in a Small Office During the Winter Season
This study proposes sustainable natural ventilation strategies using the periodic opening and closing of windows and doors to maintain acceptable indoor air quality in a small office space during the winter season. Field experiments were conducted in a 26.8 m2 university office room in Seoul, Korea, measuring the indoor and outdoor temperature, humidity, wind speed, carbon dioxide concentration, and fine dust levels. A simulation model based on a first-order differential equation was developed using EES software (version 9) to predict indoor CO2 concentrations at one-minute intervals. The simulation results showed good agreement with the experimental data, validating the accuracy of the modeling approach. Based on the validated model, practical ventilation durations and intervals were derived according to the occupant number and room volume, ensuring that indoor CO2 concentrations remained below the recommended 1000 ppm threshold. The results demonstrate that simple, periodic natural ventilation is effective in maintaining acceptable indoor air quality. As a passive strategy requiring no electrical energy, it offers a sustainable and low-cost solution for creating a healthy indoor environment.
- 28 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17  (11) , 4961
Open AccessSustainable Natural Ventilation Strategies for Acceptable Indoor Air Quality: An Experimental and Simulated Study in a Small Office During the Winter Season
This study proposes sustainable natural ventilation strategies using the periodic opening and closing of windows and doors to maintain acceptable indoor air quality in a small office space during the winter season. Field experiments were conducted in a 26.8 m2 university office room in Seoul, Korea, measuring the indoor and outdoor temperature, humidity, wind speed, carbon dioxide concentration, and fine dust levels. A simulation model based on a first-order differential equation was developed using EES software (version 9) to predict indoor CO2 concentrations at one-minute intervals. The simulation results showed good agreement with the experimental data, validating the accuracy of the modeling approach. Based on the validated model, practical ventilation durations and intervals were derived according to the occupant number and room volume, ensuring that indoor CO2 concentrations remained below the recommended 1000 ppm threshold. The results demonstrate that simple, periodic natural ventilation is effective in maintaining acceptable indoor air quality. As a passive strategy requiring no electrical energy, it offers a sustainable and low-cost solution for creating a healthy indoor environment.
- Open Access
A Data Imputation Approach for Missing Power Consumption Measurements in Water-Cooled Centrifugal Chillers
In the process of collecting operational data for the performance analysis of water-cooled centrifugal chillers, missing values are inevitable due to various factors such as sensor errors, data transmission failures, and failure of the measurement system. When a substantial amount of missing data is present, the reliability of data analysis decreases, leading to potential distortions in the results. To address this issue, it is necessary to either minimize missing occurrences by utilizing high-precision measurement equipment or apply reliable imputation techniques to compensate for missing values. This study focuses on two water-cooled turbo chillers installed in Tower A, Seoul, collecting a total of 118,464 data points over 3 years and 4 months. The dataset includes chilled water inlet and outlet temperatures ( and ) and flow rate () and cooling water inlet and outlet temperatures ( and ) and flow rate (), as well as chiller power consumption (). To evaluate the performance of various imputation techniques, we introduced missing values at a rate of 10–30% under the assumption of a missing-at-random (MAR) mechanism. Seven different imputation methods—mean, median, linear interpolation, multiple imputation, simple random imputation, k-nearest neighbors (KNN), and the dynamically clustered KNN (DC-KNN)—were applied, and their imputation performance was validated using MAPE and CVRMSE metrics. The DC-KNN method, developed in this study, improves upon conventional KNN imputation by integrating clustering and dynamic weighting mechanisms. The results indicate that DC-KNN achieved the highest predictive performance, with MAPE ranging from 9.74% to 10.30% and CVRMSE ranging from 12.19% to 13.43%. Finally, for the missing data recorded in July 2023, we applied the most effective DC-KNN method to generate imputed values that reflect the characteristics of the studied site, which employs an ice thermal energy storage system.Open AccessA Data Imputation Approach for Missing Power Consumption Measurements in Water-Cooled Centrifugal Chillers
In the process of collecting operational data for the performance analysis of water-cooled centrifugal chillers, missing values are inevitable due to various factors such as sensor errors, data transmission failures, and failure of the measurement system. When a substantial amount of missing data is present, the reliability of data analysis decreases, leading to potential distortions in the results. To address this issue, it is necessary to either minimize missing occurrences by utilizing high-precision measurement equipment or apply reliable imputation techniques to compensate for missing values. This study focuses on two water-cooled turbo chillers installed in Tower A, Seoul, collecting a total of 118,464 data points over 3 years and 4 months. The dataset includes chilled water inlet and outlet temperatures ( and ) and flow rate () and cooling water inlet and outlet temperatures ( and ) and flow rate (), as well as chiller power consumption (). To evaluate the performance of various imputation techniques, we introduced missing values at a rate of 10–30% under the assumption of a missing-at-random (MAR) mechanism. Seven different imputation methods—mean, median, linear interpolation, multiple imputation, simple random imputation, k-nearest neighbors (KNN), and the dynamically clustered KNN (DC-KNN)—were applied, and their imputation performance was validated using MAPE and CVRMSE metrics. The DC-KNN method, developed in this study, improves upon conventional KNN imputation by integrating clustering and dynamic weighting mechanisms. The results indicate that DC-KNN achieved the highest predictive performance, with MAPE ranging from 9.74% to 10.30% and CVRMSE ranging from 12.19% to 13.43%. Finally, for the missing data recorded in July 2023, we applied the most effective DC-KNN method to generate imputed values that reflect the characteristics of the studied site, which employs an ice thermal energy storage system. - Open Access
- 2 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17  (9) , 4126
Experimental Analysis of Energy Savings in a Combined Rotary Desiccant Dehumidifier with a Purge Section
This study focuses on improving the performance of desiccant dehumidifiers using desiccant rotors, which are widely utilized in various industries, such as manufacturing, food, and construction, to enhance product quality and production efficiency. The combined desiccant dehumidifier can reduce energy consumption compared to traditional standard or purge dehumidifiers. The system operates in normal mode during seasons with high outdoor humidity and in purge mode during seasons with low outdoor humidity. By utilizing dampers, the air passing through the dry desiccant rotor can either be directly discharged indoors or supplied to the regeneration section, allowing the system to operate in two modes within a single unit. The first part of the study involved comparing the performance of the equipment through experiments. The second part compared the results from the dehumidifier rotor performance simulation program to check for deviations and validate its effectiveness. In the first experiment, the energy consumption of the standard desiccant dehumidifier in normal mode was compared with that of the combined desiccant dehumidifier in normal mode. In the second experiment, the energy consumption of the standard desiccant dehumidifier in normal mode was compared with that of the combined desiccant dehumidifier in purge mode. The airflow, temperature, and humidity values used in each experiment were analyzed using a dehumidification performance simulation program, and the deviation was found to be within 10%. Therefore, the performance analysis via simulation was considered valid. The dehumidification performance of the combined desiccant dehumidifier was found to be 5% more efficient than the traditional standard desiccant dehumidifier and 9.5% more efficient than the purge dehumidifier. Furthermore, energy consumption simulations were conducted for representative regions in Korea. The results showed energy reductions of 65% in Seoul, 65% in Daejeon, and 67% in Busan. The findings of this study suggest that energy savings can be achieved by appropriately adjusting the operation mode between normal and purge modes based on outdoor conditions.
- 2 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17  (9) , 4126
Open AccessExperimental Analysis of Energy Savings in a Combined Rotary Desiccant Dehumidifier with a Purge Section
This study focuses on improving the performance of desiccant dehumidifiers using desiccant rotors, which are widely utilized in various industries, such as manufacturing, food, and construction, to enhance product quality and production efficiency. The combined desiccant dehumidifier can reduce energy consumption compared to traditional standard or purge dehumidifiers. The system operates in normal mode during seasons with high outdoor humidity and in purge mode during seasons with low outdoor humidity. By utilizing dampers, the air passing through the dry desiccant rotor can either be directly discharged indoors or supplied to the regeneration section, allowing the system to operate in two modes within a single unit. The first part of the study involved comparing the performance of the equipment through experiments. The second part compared the results from the dehumidifier rotor performance simulation program to check for deviations and validate its effectiveness. In the first experiment, the energy consumption of the standard desiccant dehumidifier in normal mode was compared with that of the combined desiccant dehumidifier in normal mode. In the second experiment, the energy consumption of the standard desiccant dehumidifier in normal mode was compared with that of the combined desiccant dehumidifier in purge mode. The airflow, temperature, and humidity values used in each experiment were analyzed using a dehumidification performance simulation program, and the deviation was found to be within 10%. Therefore, the performance analysis via simulation was considered valid. The dehumidification performance of the combined desiccant dehumidifier was found to be 5% more efficient than the traditional standard desiccant dehumidifier and 9.5% more efficient than the purge dehumidifier. Furthermore, energy consumption simulations were conducted for representative regions in Korea. The results showed energy reductions of 65% in Seoul, 65% in Daejeon, and 67% in Busan. The findings of this study suggest that energy savings can be achieved by appropriately adjusting the operation mode between normal and purge modes based on outdoor conditions.
- Open Access
- 3 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17  (5) , 2196
Performance Prediction of a Water-Cooled Centrifugal Chiller in Standard Temperature Conditions Using In-Situ Measurement Data
In this study, a regression model was developed using the thermo-regulated residual refinement regression model (TRRM) analysis method based on three years and four months of in situ data collected from two water-cooled centrifugal chillers installed in A Tower, Seoul, South Korea. The primary objective of this study was to predict the coefficient of performance (COP) of water-cooled chillers under various operating conditions using only the chilled water outlet temperature () and the cooling water inlet temperature (). The secondary objective was to estimate the COP under standard temperature conditions, which is essential for the absolute performance evaluation of chillers. The collected dataset was refined through thermodynamic preprocessing, including the removal of missing values and outliers, to ensure high data reliability. Based on this refined dataset, regression analyses were conducted separately for four cases: daytime (09:00–21:00) and nighttime (21:00–09:00) operations of chiller #1 and chiller #2, resulting in the derivation of four final regression equations. The reliability of the final dataset was further validated by applying other regression models, including simple linear (SL), bi-quadratic (BQ), and multivariate polynomial (MP) regression. The performance of each model was evaluated by calculating the coefficient of determination (), coefficient of variation of root mean square error (CVRMSE), and the p-values of each coefficient. Additionally, the predicted COP values under the design and standard temperature conditions were compared with the measured COP values to assess the accuracy of the model. Error rates were also analyzed under scenarios where and were each varied by ±1 °C. To ensure robust validation, a final comparison was performed between the predicted and measured COP values. The results demonstrated that the TRRM exhibited high reliability and predictive accuracy, with most regression equations achieving values exceeding 90%, CVRMSE below 5%, and p-values below 0.05. Furthermore, the predicted COP values closely matched the actual measured COP values, further confirming the reliability of the regression model and equations. This study provides a practical method for estimating the COP of water-cooled chillers under standard temperature conditions or other operational conditions using only and . This methodology can be utilized for objective performance assessments of chillers at various sites, supporting the development of effective maintenance strategies and performance optimization plans.- 3 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17  (5) , 2196
Open AccessPerformance Prediction of a Water-Cooled Centrifugal Chiller in Standard Temperature Conditions Using In-Situ Measurement Data
In this study, a regression model was developed using the thermo-regulated residual refinement regression model (TRRM) analysis method based on three years and four months of in situ data collected from two water-cooled centrifugal chillers installed in A Tower, Seoul, South Korea. The primary objective of this study was to predict the coefficient of performance (COP) of water-cooled chillers under various operating conditions using only the chilled water outlet temperature () and the cooling water inlet temperature (). The secondary objective was to estimate the COP under standard temperature conditions, which is essential for the absolute performance evaluation of chillers. The collected dataset was refined through thermodynamic preprocessing, including the removal of missing values and outliers, to ensure high data reliability. Based on this refined dataset, regression analyses were conducted separately for four cases: daytime (09:00–21:00) and nighttime (21:00–09:00) operations of chiller #1 and chiller #2, resulting in the derivation of four final regression equations. The reliability of the final dataset was further validated by applying other regression models, including simple linear (SL), bi-quadratic (BQ), and multivariate polynomial (MP) regression. The performance of each model was evaluated by calculating the coefficient of determination (), coefficient of variation of root mean square error (CVRMSE), and the p-values of each coefficient. Additionally, the predicted COP values under the design and standard temperature conditions were compared with the measured COP values to assess the accuracy of the model. Error rates were also analyzed under scenarios where and were each varied by ±1 °C. To ensure robust validation, a final comparison was performed between the predicted and measured COP values. The results demonstrated that the TRRM exhibited high reliability and predictive accuracy, with most regression equations achieving values exceeding 90%, CVRMSE below 5%, and p-values below 0.05. Furthermore, the predicted COP values closely matched the actual measured COP values, further confirming the reliability of the regression model and equations. This study provides a practical method for estimating the COP of water-cooled chillers under standard temperature conditions or other operational conditions using only and . This methodology can be utilized for objective performance assessments of chillers at various sites, supporting the development of effective maintenance strategies and performance optimization plans. - Open Access
Prioritizing Energy Performance Improvement Factors for Senior Centers Based on Building Energy Simulation and Economic Feasibility
This study examined energy performance improvement factors by analyzing both energy performance and the economic impacts to reduce energy costs for senior centers. A fact-finding survey was conducted on 20 senior centers in a metropolitan area, identifying key energy improvement factors. Energy simulations of the buildings were performed using ECO2, an officially certified energy assessment program in Korea, comparing the energy requirements before and after the improvements. The energy demand, energy consumption, and floor area were analyzed, with the J, K, and S standard models selected based on the median values of these factors. To assess the impact of the improvements, blower door tests were conducted on two senior centers before and after window upgrades. Based on the ECO2 simulations and the blower door test results, improvement priorities were identified in the following order: windows, exterior walls, boilers, roofs, and doors. Finally, an economic feasibility analysis applied the construction and heating costs to the standard models. Over a 40-year period, only boiler improvements generated a net profit. Without government support, this study recommends prioritizing boiler upgrades when selecting energy performance improvements.
Open AccessPrioritizing Energy Performance Improvement Factors for Senior Centers Based on Building Energy Simulation and Economic Feasibility
This study examined energy performance improvement factors by analyzing both energy performance and the economic impacts to reduce energy costs for senior centers. A fact-finding survey was conducted on 20 senior centers in a metropolitan area, identifying key energy improvement factors. Energy simulations of the buildings were performed using ECO2, an officially certified energy assessment program in Korea, comparing the energy requirements before and after the improvements. The energy demand, energy consumption, and floor area were analyzed, with the J, K, and S standard models selected based on the median values of these factors. To assess the impact of the improvements, blower door tests were conducted on two senior centers before and after window upgrades. Based on the ECO2 simulations and the blower door test results, improvement priorities were identified in the following order: windows, exterior walls, boilers, roofs, and doors. Finally, an economic feasibility analysis applied the construction and heating costs to the standard models. Over a 40-year period, only boiler improvements generated a net profit. Without government support, this study recommends prioritizing boiler upgrades when selecting energy performance improvements.
- Open Access
Economic Evaluation of Small Public Office Buildings with Class 1 of Zero Energy Building (ZEB) in Korea by Reflecting Life Cycle Assessment (LCA)
This study summarizes the technology level and economic feasibility of two small 500 m2 public office buildings that achieved a first-class Zero Energy Buildings (ZEB) certification for the first time in Korea. In addition, a Life Cycle Assessment (LCA) reflecting the ZEB performance in the operation stage was analyzed, and the LCA factors considering the characteristics of small buildings were reviewed. Moreover, an economic analysis was performed through a Net Present Value (NPV) by reflecting the ZEB and LCA, and the results showed little economic feasibility. However, adding the environmental costs calculated through the LCA to the existing energy-saving costs could offset an additional 11.6–11.7%. Therefore, including the environmental impact and cost through these LCA evaluation techniques could be a positive step toward increasing the effectiveness of ZEB applications. This study is significant in that it conducted a comprehensive analysis through ZEB and LCA in terms of carbon reduction for small buildings that achieved a first-class ZEB certification, but it is limited to only two cases.
Open AccessEconomic Evaluation of Small Public Office Buildings with Class 1 of Zero Energy Building (ZEB) in Korea by Reflecting Life Cycle Assessment (LCA)
This study summarizes the technology level and economic feasibility of two small 500 m2 public office buildings that achieved a first-class Zero Energy Buildings (ZEB) certification for the first time in Korea. In addition, a Life Cycle Assessment (LCA) reflecting the ZEB performance in the operation stage was analyzed, and the LCA factors considering the characteristics of small buildings were reviewed. Moreover, an economic analysis was performed through a Net Present Value (NPV) by reflecting the ZEB and LCA, and the results showed little economic feasibility. However, adding the environmental costs calculated through the LCA to the existing energy-saving costs could offset an additional 11.6–11.7%. Therefore, including the environmental impact and cost through these LCA evaluation techniques could be a positive step toward increasing the effectiveness of ZEB applications. This study is significant in that it conducted a comprehensive analysis through ZEB and LCA in terms of carbon reduction for small buildings that achieved a first-class ZEB certification, but it is limited to only two cases.