Antônia D. P. Bankoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Antônia D. P. Bankoff has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Sanchez
Federal University of Mato Grosso do Sul. Avenue Ranulpho Marquês Leal, 3484, Três Lagoas 79620-080, Mato Grosso do Sul, Brazil
1 shared publication - Sonia Regina Jurado
Universidade Federal de Mato Grosso do Sul
1 shared publication
Latest Publications
- Open Access
- 11 July 2014
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 11 (7) , 7081-7093
Indoor Air Quality in Brazilian Universities
This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (3) in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively). The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.
- 11 July 2014
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 11 (7) , 7081-7093
Open AccessIndoor Air Quality in Brazilian Universities
This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (3) in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively). The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.