Hilde Vandenneucker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hilde Vandenneucker has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Pieter Berger
University Hospitals Leuven
3 shared publications Johan Bellemans
Department of Development and Regeneration - Orthopaedic Surgery, University Hospitals Leuven, Weligerveld 1, 3212, Pellenberg-Lubbeek, Belgium
2 shared publicationsJos Vander Sloten
Biomechanics Section, University of Leuven, Celestijnenlaan 300c, 3000, Leuven, Belgium
2 shared publications- Kaat Desloovere
Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium
2 shared publications - Lennart Scheys
Department of Development and Regeneration, Faculty of Medicine Institute for Orthopaedic Research and Training (IORT), KU Leuven Leuven Belgium
2 shared publications Luc Labey
European Centre for Knee Research, Smith&Nephew, Technologielaan 11 bis, 3000, Leuven, Belgium
2 shared publications
Latest Publications
- 9 August 2023
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (11) , 4798-4808
NAVIO RATKA shows similar rates of hemoglobin‐drop, adverse events, readmission and early revision vs conventional TKA: a single centre retrospective cohort study
Purpose: Despite widespread adoption of NAVIO robotic‐assisted total knee arthroplasty (NAVIO RATKA) in clinical practice, clinical outcome in terms of adverse events and complications remains unclear. The purpose of this study was to compare adverse events, length of stay, surgical time, hemoglobin drop, early readmission rate and revision rate between conventional TKA (CTKA) and NAVIO RATKA.Methods: This single‐centre retrospective cohort analysis compared 230 NAVIO RATKA patients to 489 CTKA patients with a minimal follow‐up of 12 months. Baseline demographic and comorbidity parameters were collected, as well as length of stay, revision rate and reason for revision, early readmission rate (< 6w) and reason for readmission, post‐operative hemoglobin levels, adverse events, surgical time and operating room time. Data were compared using Mann–Whitney U test for continuous data without normal distribution and ordinal data, categorical variables were compared using the Chi‐square or Fisher exact test.Results: There were no clinically relevant baseline demographic or comorbidity differences between groups. CTKA had shorter length of stay than NAVIO RATKA (5.0 days vs 5.4 days, p = 0.010) but trended towards a higher reoperation rate (4.1% vs 1.7%, p = .144, n.s). No differences were found in hemoglobin drop, readmission rate or overall incidence of adverse events, but CTKA showed more hematoma formation (1.6% vs 0%, p = .044) and higher incidence of periprosthetic joint infection (PJI) (1% vs 0%, p = n.s.), whilst NAVIO RATKA showed more periprosthetic fractures and persistent wound drainage (0.4% vs 2.2%, p = .038 and 0.6% vs 4.3%, p = .001, respectively). Surgical time remained significantly longer in NAVIO RATKA during all 230 cases (87 min vs 67.6 min) and showed a continuous downward trend.Conclusions: This study further validates the usage of NAVIO RATKA as a safe method to perform TKA, with comparable short term outcomes to CTKA in terms of early revisions and adverse events. Surgeons should be mindful of the differing adverse event profile in NAVIO RATKA and adjust their patient selection accordingly to ensure optimal outcomes. In addition, surgeons using NAVIO RATKA should expect a linear learning curve and a surgical time exceeding that of CTKA.Level of evidence: Level III (therapeutic retrospective cohort study).
- 9 August 2023
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (11) , 4798-4808
NAVIO RATKA shows similar rates of hemoglobin‐drop, adverse events, readmission and early revision vs conventional TKA: a single centre retrospective cohort study
Purpose: Despite widespread adoption of NAVIO robotic‐assisted total knee arthroplasty (NAVIO RATKA) in clinical practice, clinical outcome in terms of adverse events and complications remains unclear. The purpose of this study was to compare adverse events, length of stay, surgical time, hemoglobin drop, early readmission rate and revision rate between conventional TKA (CTKA) and NAVIO RATKA.Methods: This single‐centre retrospective cohort analysis compared 230 NAVIO RATKA patients to 489 CTKA patients with a minimal follow‐up of 12 months. Baseline demographic and comorbidity parameters were collected, as well as length of stay, revision rate and reason for revision, early readmission rate (< 6w) and reason for readmission, post‐operative hemoglobin levels, adverse events, surgical time and operating room time. Data were compared using Mann–Whitney U test for continuous data without normal distribution and ordinal data, categorical variables were compared using the Chi‐square or Fisher exact test.Results: There were no clinically relevant baseline demographic or comorbidity differences between groups. CTKA had shorter length of stay than NAVIO RATKA (5.0 days vs 5.4 days, p = 0.010) but trended towards a higher reoperation rate (4.1% vs 1.7%, p = .144, n.s). No differences were found in hemoglobin drop, readmission rate or overall incidence of adverse events, but CTKA showed more hematoma formation (1.6% vs 0%, p = .044) and higher incidence of periprosthetic joint infection (PJI) (1% vs 0%, p = n.s.), whilst NAVIO RATKA showed more periprosthetic fractures and persistent wound drainage (0.4% vs 2.2%, p = .038 and 0.6% vs 4.3%, p = .001, respectively). Surgical time remained significantly longer in NAVIO RATKA during all 230 cases (87 min vs 67.6 min) and showed a continuous downward trend.Conclusions: This study further validates the usage of NAVIO RATKA as a safe method to perform TKA, with comparable short term outcomes to CTKA in terms of early revisions and adverse events. Surgeons should be mindful of the differing adverse event profile in NAVIO RATKA and adjust their patient selection accordingly to ensure optimal outcomes. In addition, surgeons using NAVIO RATKA should expect a linear learning curve and a surgical time exceeding that of CTKA.Level of evidence: Level III (therapeutic retrospective cohort study).
- 21 March 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (9) , 5501-5506
Operating room efficiency after the implementation of MAKO robotic-assisted total knee arthroplasty
Introduction The aim of this study was to examine if robotic-assisted total knee arthroplasty (RATKA) is cost- and time-effective in terms of implant stock and perioperative parameters, as optimizing perioperative efficiency may contribute to value-based care. Materials and methods Four hundred thirty-two consecutive patients who received primary total knee arthroplasties (TKAs) from May 2017 to March 2020 in a regional hospital were included in this study. Operating room time (OR time), surgical time, number of trays, insert thickness, and length of stay (LOS) were assessed and compared for a cohort group with navigation-assisted procedures to a group with robotic-assisted procedures (MAKO, Stryker, USA). Prediction of implant size was assessed for the robotic-assisted group. The Mann–Whitney U test was used for comparisons between groups when the normality assumption was not met. Categorical variables were assessed using the Fisher’s exact test. p < 0.05 was considered statistically significant. Results In the RATKA group, we noticed a significant mean reduction of 11 min in total OR time (p < 0.001), the use of thinner insert (p < 0.001), and a shorter mean length of stay of 1 day (p < 0.001). Compared to the navigation group, surgical time was not significantly longer, nor clinically relevant (0.238). In 76.9% of the robotic-assisted cases, the estimated implant size was equal to the final size and in all other cases, the preoperative implant size was oversized. Conclusion The introduction of the MAKO robotic-assisted total knee arthroplasty resulted in a gain in operating room time, a thinner and more predictable insert thickness, a shorter length of stay in hospital, and less instrumentation compared to navigation-assisted procedures. Level of evidence Level III, Retrospective cohort study.
- 21 March 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (9) , 5501-5506
Operating room efficiency after the implementation of MAKO robotic-assisted total knee arthroplasty
Introduction The aim of this study was to examine if robotic-assisted total knee arthroplasty (RATKA) is cost- and time-effective in terms of implant stock and perioperative parameters, as optimizing perioperative efficiency may contribute to value-based care. Materials and methods Four hundred thirty-two consecutive patients who received primary total knee arthroplasties (TKAs) from May 2017 to March 2020 in a regional hospital were included in this study. Operating room time (OR time), surgical time, number of trays, insert thickness, and length of stay (LOS) were assessed and compared for a cohort group with navigation-assisted procedures to a group with robotic-assisted procedures (MAKO, Stryker, USA). Prediction of implant size was assessed for the robotic-assisted group. The Mann–Whitney U test was used for comparisons between groups when the normality assumption was not met. Categorical variables were assessed using the Fisher’s exact test. p < 0.05 was considered statistically significant. Results In the RATKA group, we noticed a significant mean reduction of 11 min in total OR time (p < 0.001), the use of thinner insert (p < 0.001), and a shorter mean length of stay of 1 day (p < 0.001). Compared to the navigation group, surgical time was not significantly longer, nor clinically relevant (0.238). In 76.9% of the robotic-assisted cases, the estimated implant size was equal to the final size and in all other cases, the preoperative implant size was oversized. Conclusion The introduction of the MAKO robotic-assisted total knee arthroplasty resulted in a gain in operating room time, a thinner and more predictable insert thickness, a shorter length of stay in hospital, and less instrumentation compared to navigation-assisted procedures. Level of evidence Level III, Retrospective cohort study.
- Open Access
- 1 December 2021
- Published by Universa BV in Acta Orthopaedica Belgica
- Vol. 87 (4) , 681-695
Metal wear debris generation in primary total knee arthroplasty: is it an issue?
More durable total knee arthroplasties (TKAs) are needed, due to the rising life expectancy, the higher activity levels of patients and the growing concerns about aseptic loosening being caused by metal hypersensitivity. In response, different hypoallergenic metal coatings have been developed for TKAs. However, possible adverse effects of these different metals (cobalt-chromium-molybdenum, zirconium, titanium and tantalum) have been neglected. The aim was to summarize the local and systemic adverse effects (including metal hypersensitivity), survival ratios, patient-reported outcome measures (PROMs) and the plasma metal ion concentrations of the different TKA coatings. A literature search on PubMed and EMBASE was performed. In total, 15 studies were found eligible. Common adverse effects of TKA were infection, loosening, pain, instability and hyper- coagulation disorders. Serious adverse effects related to TKA implants were not reported. The survival ratios and patient-reported outcome measures seem to confirm these good results. In contrast with chromium and cobalt, no significant differences were reported in the nickel, molybdenum and titanium concentrations. No significant differences between the hypoallergenic and standard TKA implants were found in terms of adverse effects, survival ratios and PROMs. A causal relationship between the common adverse effects and the different metals is unlikely. Due to the heterogeneity of the TKA implants used, no firm conclusions could be made. Further research with longer follow-up studies are needed to find possible adverse effects and differences. Thus far, the hypoallergenic implants seem to perform equal to the standard implants.
- 1 December 2021
- Published by Universa BV in Acta Orthopaedica Belgica
- Vol. 87 (4) , 681-695
Open AccessMetal wear debris generation in primary total knee arthroplasty: is it an issue?
More durable total knee arthroplasties (TKAs) are needed, due to the rising life expectancy, the higher activity levels of patients and the growing concerns about aseptic loosening being caused by metal hypersensitivity. In response, different hypoallergenic metal coatings have been developed for TKAs. However, possible adverse effects of these different metals (cobalt-chromium-molybdenum, zirconium, titanium and tantalum) have been neglected. The aim was to summarize the local and systemic adverse effects (including metal hypersensitivity), survival ratios, patient-reported outcome measures (PROMs) and the plasma metal ion concentrations of the different TKA coatings. A literature search on PubMed and EMBASE was performed. In total, 15 studies were found eligible. Common adverse effects of TKA were infection, loosening, pain, instability and hyper- coagulation disorders. Serious adverse effects related to TKA implants were not reported. The survival ratios and patient-reported outcome measures seem to confirm these good results. In contrast with chromium and cobalt, no significant differences were reported in the nickel, molybdenum and titanium concentrations. No significant differences between the hypoallergenic and standard TKA implants were found in terms of adverse effects, survival ratios and PROMs. A causal relationship between the common adverse effects and the different metals is unlikely. Due to the heterogeneity of the TKA implants used, no firm conclusions could be made. Further research with longer follow-up studies are needed to find possible adverse effects and differences. Thus far, the hypoallergenic implants seem to perform equal to the standard implants.
- Open Access
Can Intraoperative Intra-Articular Loads Predict Postoperative Knee Joint Laxity Following Total Knee Arthroplasty? A Cadaver Study with Smart Tibial Trays
Ligament balancing during total knee arthroplasty (TKA) often relies on subjective surgeon experience. Although instrumented tibial trays facilitate an objective assessment of intraoperative joint balance through quantification of intra-articular joint loads, postoperative clinical assessment of joint balance relies on passive stress tests quantifying varus–valgus joint laxity. This study aimed at correlating the intraoperative and postoperative metrics used to assess joint balance while also comparing joint loads obtained during passive assessment and active functional motions. Four experienced surgical fellows were assigned a fresh-frozen lower limb each to plan and perform posterior-stabilised TKA. An instrumented tibial insert measured intraoperative intra-articular loads. Specimens were then subjected to passive flexion–extension, open-chain extension, active squatting, and varus–valgus laxity tests on a validated knee simulator. Intra-articular loads were recorded using the instrumented insert and tibiofemoral kinematics using an optical motion capture system. A negative correlation was observed between mean intraoperative intra-articular loads and corresponding mean postoperative tibial abduction angle during laxity tests (medial: R = −0.93, p = 0.02; lateral: R = −0.88, p = 0.04); however, this was not observed for each specimen. Peak intra-articular load distribution for active squatting was lateral-heavy, contrasting to the medial-heavy distribution observed in passive intraoperative measurements, for all specimens. These aspects should be given due consideration while assessing intraoperative and postoperative joint stability following TKA.
Open AccessCan Intraoperative Intra-Articular Loads Predict Postoperative Knee Joint Laxity Following Total Knee Arthroplasty? A Cadaver Study with Smart Tibial Trays
Ligament balancing during total knee arthroplasty (TKA) often relies on subjective surgeon experience. Although instrumented tibial trays facilitate an objective assessment of intraoperative joint balance through quantification of intra-articular joint loads, postoperative clinical assessment of joint balance relies on passive stress tests quantifying varus–valgus joint laxity. This study aimed at correlating the intraoperative and postoperative metrics used to assess joint balance while also comparing joint loads obtained during passive assessment and active functional motions. Four experienced surgical fellows were assigned a fresh-frozen lower limb each to plan and perform posterior-stabilised TKA. An instrumented tibial insert measured intraoperative intra-articular loads. Specimens were then subjected to passive flexion–extension, open-chain extension, active squatting, and varus–valgus laxity tests on a validated knee simulator. Intra-articular loads were recorded using the instrumented insert and tibiofemoral kinematics using an optical motion capture system. A negative correlation was observed between mean intraoperative intra-articular loads and corresponding mean postoperative tibial abduction angle during laxity tests (medial: R = −0.93, p = 0.02; lateral: R = −0.88, p = 0.04); however, this was not observed for each specimen. Peak intra-articular load distribution for active squatting was lateral-heavy, contrasting to the medial-heavy distribution observed in passive intraoperative measurements, for all specimens. These aspects should be given due consideration while assessing intraoperative and postoperative joint stability following TKA.
- Open Access
Validated Ultrasound Speckle Tracking Method for Measuring Strains of Knee Collateral Ligaments In-Situ during Varus/Valgus Loading
Current ultrasound techniques face several challenges to measure strains when translated from large tendon to in-situ knee collateral ligament applications, despite the potential to reduce knee arthroplasty failures attributed to ligament imbalance. Therefore, we developed, optimized and validated an ultrasound speckle tracking method to assess the in-situ strains of the medial and lateral collateral ligaments. Nine cadaveric legs with total knee implants were submitted to varus/valgus loading and divided into two groups: “optimization” and “validation”. Reference strains were measured using digital image correlation technique, while ultrasound data were processed with a custom-built speckle tracking approach. Using specimens from the “optimization” group, several tracking parameters were tuned towards an optimized tracking performance. The parameters were ranked according to three comparative measures between the ultrasound-based and reference strains: R2, mean absolute error and strains differences at 40 N. Specimens from the “validation” group, processed with the optimal parameters, showed good correlations, along with small mean absolute differences, with correlation values above 0.99 and 0.89 and differences below 0.57% and 0.27% for the lateral and medial collateral ligaments, respectively. This study showed that ultrasound speckle tracking could assess knee collateral ligaments strains in situ and has the potential to be translated to clinics for knee arthroplasty-related procedures.
Open AccessValidated Ultrasound Speckle Tracking Method for Measuring Strains of Knee Collateral Ligaments In-Situ during Varus/Valgus Loading
Current ultrasound techniques face several challenges to measure strains when translated from large tendon to in-situ knee collateral ligament applications, despite the potential to reduce knee arthroplasty failures attributed to ligament imbalance. Therefore, we developed, optimized and validated an ultrasound speckle tracking method to assess the in-situ strains of the medial and lateral collateral ligaments. Nine cadaveric legs with total knee implants were submitted to varus/valgus loading and divided into two groups: “optimization” and “validation”. Reference strains were measured using digital image correlation technique, while ultrasound data were processed with a custom-built speckle tracking approach. Using specimens from the “optimization” group, several tracking parameters were tuned towards an optimized tracking performance. The parameters were ranked according to three comparative measures between the ultrasound-based and reference strains: R2, mean absolute error and strains differences at 40 N. Specimens from the “validation” group, processed with the optimal parameters, showed good correlations, along with small mean absolute differences, with correlation values above 0.99 and 0.89 and differences below 0.57% and 0.27% for the lateral and medial collateral ligaments, respectively. This study showed that ultrasound speckle tracking could assess knee collateral ligaments strains in situ and has the potential to be translated to clinics for knee arthroplasty-related procedures.
- 1 January 2021
- Published by Elsevier in Gait & Posture
- Vol. 83, 44-51
Athletes with an ACL reconstruction show a different neuromuscular response to environmental challenges compared to uninjured athletes
- 1 January 2021
- Published by Elsevier in Gait & Posture
- Vol. 83, 44-51
Athletes with an ACL reconstruction show a different neuromuscular response to environmental challenges compared to uninjured athletes
- Open Access
- 1 March 2019
- Published by Springer Nature in BMC Medical Education
- Vol. 19 (1) , 66
Educational outreach visits to improve knee osteoarthritis management in primary care
Knee osteoarthritis is a common problem, but often underdiagnosed and undertreated in primary care as compared to evidence-based guidelines. Educational outreach visits are an effective strategy to improve guideline adherence, but its contribution to knee osteoarthritis management is largely unknown. The aim of this study was to evaluate the overall effectiveness of educational outreach visits on process quality indicators for knee osteoarthritis management, more specifically on the referral for physical therapy. An educational intervention study, non-randomized and controlled, was designed for general practitioners (GPs) in Belgium. During four months, 426 GPs were visited by academic detailers and allocated to the intervention group. The control group was selected from GPs not visited by academic detailers during the study period. Six months post-intervention, both groups received a questionnaire with two case-vignettes to measure the effectiveness of the educational outreach. Outcomes were assessed with a Belgian set of quality indicators for knee osteoarthritis management and focused on the number of prescriptions for appropriate physical therapy (i.e. muscle strengthening, aerobic, functional or range of motion exercises) and the adherence to eight additional quality indicators related to knee osteoarthritis management. For the analysis, multivariable logistic regression models were used and Generalized Estimating Equations to handle the correlation between the multiple results per GP. The intervention group showed a tendency to prescribe more frequently at least one appropriate physical therapy for a case (43.8%), compared to the control group (31.3%, p = 0.057). Muscle strengthening exercises were the most frequently prescribed therapy with 37.0% in the intervention versus 26.9% in the control group. The adherence to the other quality indicators showed no significant difference between the intervention and control group and varied between 8.9 and 100% in the intervention group. This intervention did not alter significantly the adherence to quality indicators and in particular the probability of prescribing physical therapy. To change general practitioners’ prescription behavior, more extensive or combined interventional approaches seem warranted.
- 1 March 2019
- Published by Springer Nature in BMC Medical Education
- Vol. 19 (1) , 66
Open AccessEducational outreach visits to improve knee osteoarthritis management in primary care
Knee osteoarthritis is a common problem, but often underdiagnosed and undertreated in primary care as compared to evidence-based guidelines. Educational outreach visits are an effective strategy to improve guideline adherence, but its contribution to knee osteoarthritis management is largely unknown. The aim of this study was to evaluate the overall effectiveness of educational outreach visits on process quality indicators for knee osteoarthritis management, more specifically on the referral for physical therapy. An educational intervention study, non-randomized and controlled, was designed for general practitioners (GPs) in Belgium. During four months, 426 GPs were visited by academic detailers and allocated to the intervention group. The control group was selected from GPs not visited by academic detailers during the study period. Six months post-intervention, both groups received a questionnaire with two case-vignettes to measure the effectiveness of the educational outreach. Outcomes were assessed with a Belgian set of quality indicators for knee osteoarthritis management and focused on the number of prescriptions for appropriate physical therapy (i.e. muscle strengthening, aerobic, functional or range of motion exercises) and the adherence to eight additional quality indicators related to knee osteoarthritis management. For the analysis, multivariable logistic regression models were used and Generalized Estimating Equations to handle the correlation between the multiple results per GP. The intervention group showed a tendency to prescribe more frequently at least one appropriate physical therapy for a case (43.8%), compared to the control group (31.3%, p = 0.057). Muscle strengthening exercises were the most frequently prescribed therapy with 37.0% in the intervention versus 26.9% in the control group. The adherence to the other quality indicators showed no significant difference between the intervention and control group and varied between 8.9 and 100% in the intervention group. This intervention did not alter significantly the adherence to quality indicators and in particular the probability of prescribing physical therapy. To change general practitioners’ prescription behavior, more extensive or combined interventional approaches seem warranted.
- 9 November 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (11) , 3668-3677
Isolated patellofemoral arthroplasty reproduces natural patellofemoral joint kinematics when the patella is resurfaced
Purpose: The objectives of this in vitro project were to compare the dynamic three‐dimensional patellofemoral kinematics, contact forces, contact areas and contact pressures of a contemporary patellofemoral prosthetic implant with those of the native knee and to measure the influence of patellar resurfacing and patellar thickness. The hypothesis was that these designs are capable to reproduce the natural kinematics but result in higher contact pressures.Methods: Six fresh‐frozen specimens were tested on a custom‐made mechanical knee rig before and after prosthetic trochlear resurfacing, without and with patellar resurfacing in three different patellar thicknesses. Full three‐dimensional kinematics were analysed during three different motor tasks, using infrared motion capture cameras and retroflective markers. Patellar contact characteristics were registered using a pressure measuring device.Results: The patellofemoral kinematic behaviour of the patellofemoral arthroplasty was similar to that of the normal knee when the patella was resurfaced, showing only significant (p < 0.0001) changes in patellar flexion. Without patellar resurfacing, significant more patellar flexion, lateral tilt and lateral rotation was noticed. Compared to the normal knee, contact pressures were significantly elevated after isolated trochlear resurfacing. However, the values were more than doubled after patellar resurfacing. Changes in patellar thickness only influenced the antero‐posterior patellar position. There was no other influence on the kinematics, and only a limited influence on the contact pressures in the low flexion angles.Conclusion: The investigated design reproduced the normal patellofemoral kinematics acceptable well when the patella was resurfaced. From a kinematic point of view, patellar resurfacing may be advisable. However, the substantially elevated patellar contact pressures remain a point of concern in the decision whether or not to resurface the patella. This study therefore not only adds a new point in the discussion whether or not to resurface the patella, but also supports the claimed advantage that a patellofemoral arthroplasty is capable to reproduce the natural knee kinematics.
- 9 November 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (11) , 3668-3677
Isolated patellofemoral arthroplasty reproduces natural patellofemoral joint kinematics when the patella is resurfaced
Purpose: The objectives of this in vitro project were to compare the dynamic three‐dimensional patellofemoral kinematics, contact forces, contact areas and contact pressures of a contemporary patellofemoral prosthetic implant with those of the native knee and to measure the influence of patellar resurfacing and patellar thickness. The hypothesis was that these designs are capable to reproduce the natural kinematics but result in higher contact pressures.Methods: Six fresh‐frozen specimens were tested on a custom‐made mechanical knee rig before and after prosthetic trochlear resurfacing, without and with patellar resurfacing in three different patellar thicknesses. Full three‐dimensional kinematics were analysed during three different motor tasks, using infrared motion capture cameras and retroflective markers. Patellar contact characteristics were registered using a pressure measuring device.Results: The patellofemoral kinematic behaviour of the patellofemoral arthroplasty was similar to that of the normal knee when the patella was resurfaced, showing only significant (p < 0.0001) changes in patellar flexion. Without patellar resurfacing, significant more patellar flexion, lateral tilt and lateral rotation was noticed. Compared to the normal knee, contact pressures were significantly elevated after isolated trochlear resurfacing. However, the values were more than doubled after patellar resurfacing. Changes in patellar thickness only influenced the antero‐posterior patellar position. There was no other influence on the kinematics, and only a limited influence on the contact pressures in the low flexion angles.Conclusion: The investigated design reproduced the normal patellofemoral kinematics acceptable well when the patella was resurfaced. From a kinematic point of view, patellar resurfacing may be advisable. However, the substantially elevated patellar contact pressures remain a point of concern in the decision whether or not to resurface the patella. This study therefore not only adds a new point in the discussion whether or not to resurface the patella, but also supports the claimed advantage that a patellofemoral arthroplasty is capable to reproduce the natural knee kinematics.
- 15 July 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (10) , 2560-2568
Patellofemoral arthroplasty influences tibiofemoral kinematics: the effect of patellar thickness
Purpose: Although controversy still remains, isolated patellofemoral arthroplasty recently gained in popularity as a treatment option for patellofemoral osteoarthritis. It has compared to total knee arthroplasty the advantage of preserving the tibiofemoral articulation, which in theory would allow the preservation of natural tibiofemoral kinematics. Today, however, no data exist to support this assumption. This study was therefore performed in order to investigate the effect of isolated patellofemoral arthroplasty on the native three‐dimensional tibiofemoral kinematic behaviour and whether a change in patellar thickness would have an influence.Methods: Six fresh‐frozen cadavers were fixed on a custom‐made mechanical knee rig. Full 3D kinematics was analysed during passive flexion–extension cycles, open chain extension, with and without mechanical resistance, as well as deep knee squats, using infrared motion capture cameras and retroflective markers. Measurements were taken for the native knee and after prosthetic trochlear resurfacing with and without patellar resurfacing in three different patellar thicknesses.Results: Compared to the natural knee, patellofemoral arthroplasty resulted in significant changes in tibiofemoral kinematics, which were most pronounced in the most loaded motor tasks. Increased internal tibial rotation was noted in the mid‐ and high flexion ranges, reaching at 120° of flexion a mean difference of 4.5° ± 4.3° (p < 0.0001) during squat motion, over the whole flexion range during open chain motion and in deeper flexion beyond 50° (mean at 70°, 1.9° ± 3.7°) during resisted open chain. During squats, also, a more posterior translation of the lateral femoral condyle was observed. The effect was accentuated in case of patella overstuffing, whereas kinematics was closer to normal with patellar thinning.Conclusion: Isolated patellofemoral arthroplasty alters natural tibiofemoral kinematics, and the effects become more pronounced in case of increased patellar thickness. Therefore, it might be recommended to aim for a slight over‐resection of patellar bone if sufficient bone stock is available.
- 15 July 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (10) , 2560-2568
Patellofemoral arthroplasty influences tibiofemoral kinematics: the effect of patellar thickness
Purpose: Although controversy still remains, isolated patellofemoral arthroplasty recently gained in popularity as a treatment option for patellofemoral osteoarthritis. It has compared to total knee arthroplasty the advantage of preserving the tibiofemoral articulation, which in theory would allow the preservation of natural tibiofemoral kinematics. Today, however, no data exist to support this assumption. This study was therefore performed in order to investigate the effect of isolated patellofemoral arthroplasty on the native three‐dimensional tibiofemoral kinematic behaviour and whether a change in patellar thickness would have an influence.Methods: Six fresh‐frozen cadavers were fixed on a custom‐made mechanical knee rig. Full 3D kinematics was analysed during passive flexion–extension cycles, open chain extension, with and without mechanical resistance, as well as deep knee squats, using infrared motion capture cameras and retroflective markers. Measurements were taken for the native knee and after prosthetic trochlear resurfacing with and without patellar resurfacing in three different patellar thicknesses.Results: Compared to the natural knee, patellofemoral arthroplasty resulted in significant changes in tibiofemoral kinematics, which were most pronounced in the most loaded motor tasks. Increased internal tibial rotation was noted in the mid‐ and high flexion ranges, reaching at 120° of flexion a mean difference of 4.5° ± 4.3° (p < 0.0001) during squat motion, over the whole flexion range during open chain motion and in deeper flexion beyond 50° (mean at 70°, 1.9° ± 3.7°) during resisted open chain. During squats, also, a more posterior translation of the lateral femoral condyle was observed. The effect was accentuated in case of patella overstuffing, whereas kinematics was closer to normal with patellar thinning.Conclusion: Isolated patellofemoral arthroplasty alters natural tibiofemoral kinematics, and the effects become more pronounced in case of increased patellar thickness. Therefore, it might be recommended to aim for a slight over‐resection of patellar bone if sufficient bone stock is available.