Joseph L. Thomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joseph L. Thomas has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Amy H. Kaji
Department of Emergency Medicine, Harbor UCLA Medical Center, Torrance, California
1 shared publicationAram Gabrielyan
1 shared publicationChristina Economides
1 shared publicationDamian Grovas Abad
1 shared publicationDavid M. Shavelle
Division of Cardiology, University of Southern California, Los Angeles, California
1 shared publication- David M. Shavelle
Division of Cardiology, Harbor‐UCLA Medical Center, Torrance, California
1 shared publication
Latest Publications
- 23 June 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (12) , 1841-1848
The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease
The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.
- 23 June 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (12) , 1841-1848
The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease
The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.
- 31 August 2016
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 33 (1) , 129-136
A novel approach to diagnosing coronary artery disease: acoustic detection of coronary turbulence
Atherosclerotic disease within coronary arteries causes disruption of normal, laminar flow and generates flow turbulence. The characteristic acoustic waves generated by coronary turbulence serve as a novel diagnostic target. The frequency range and timing of microbruits associated with obstructive coronary artery disease (CAD) have been characterized. Technological advancements in sensor, data filtering and analytic capabilities may allow use of intracoronary turbulence for diagnostic and risk stratification purposes. Acoustic detection (AD) systems are based on the premise that the faint auditory signature of obstructive CAD can be isolated and analyzed to provide a new approach to noninvasive testing. The cardiac sonospectrographic analyzer, CADence, and CADScore systems are early-stage, investigational and commercialized examples of AD systems, with the latter two currently undergoing clinical testing with validation of accuracy using computed tomography and invasive angiography. Noninvasive imaging accounts for a large percentage of healthcare expenditures for cardiovascular disease in the developed world, and the growing burden of CAD will disproportionately affect areas in the developing world. AD is a portable, radiation-free, cost-effective method with the potential to provide accurate diagnosis or exclusion of significant CAD. AD represents a model for digital, miniaturized, and internet-connected diagnostic technologies.
- 31 August 2016
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 33 (1) , 129-136
A novel approach to diagnosing coronary artery disease: acoustic detection of coronary turbulence
Atherosclerotic disease within coronary arteries causes disruption of normal, laminar flow and generates flow turbulence. The characteristic acoustic waves generated by coronary turbulence serve as a novel diagnostic target. The frequency range and timing of microbruits associated with obstructive coronary artery disease (CAD) have been characterized. Technological advancements in sensor, data filtering and analytic capabilities may allow use of intracoronary turbulence for diagnostic and risk stratification purposes. Acoustic detection (AD) systems are based on the premise that the faint auditory signature of obstructive CAD can be isolated and analyzed to provide a new approach to noninvasive testing. The cardiac sonospectrographic analyzer, CADence, and CADScore systems are early-stage, investigational and commercialized examples of AD systems, with the latter two currently undergoing clinical testing with validation of accuracy using computed tomography and invasive angiography. Noninvasive imaging accounts for a large percentage of healthcare expenditures for cardiovascular disease in the developed world, and the growing burden of CAD will disproportionately affect areas in the developing world. AD is a portable, radiation-free, cost-effective method with the potential to provide accurate diagnosis or exclusion of significant CAD. AD represents a model for digital, miniaturized, and internet-connected diagnostic technologies.
- 1 October 2014
- Published by Elsevier in The American Journal of Cardiology
- Vol. 114 (7) , 968-971
Treatment and Outcomes of ST Segment Elevation Myocardial Infarction and Out-of-Hospital Cardiac Arrest in a Regionalized System of Care Based on Presence or Absence of Initial Shockable Cardiac Arrest Rhythm
- 1 October 2014
- Published by Elsevier in The American Journal of Cardiology
- Vol. 114 (7) , 968-971
Treatment and Outcomes of ST Segment Elevation Myocardial Infarction and Out-of-Hospital Cardiac Arrest in a Regionalized System of Care Based on Presence or Absence of Initial Shockable Cardiac Arrest Rhythm
- 1 February 2014
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 7 (2) , S55
CRT-711 Publicly Reported Adverse Events with the Edwards SAPIEN Valve - Trends and Event Classification in the FDA MAUDE Database
- 1 February 2014
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 7 (2) , S55
CRT-711 Publicly Reported Adverse Events with the Edwards SAPIEN Valve - Trends and Event Classification in the FDA MAUDE Database
- 1 February 2012
- Vol. 24 (2) , 79-83
Coronary imaging and intervention during cardiovascular collapse: use of the LUCAS mechanical CPR device in the cardiac catheterization laboratory.
The management of cardiac arrest during coronary angiography and intervention presents substantial challenges. Patients presenting with ST-segment elevation myocardial infarction or following resuscitation from cardiac arrest are at greatest risk and may represent a significant portion of patients in some centers. Timely and effective cardiopulmonary resuscitation (CPR), with manual chest compressions is the primary mode of support though novel circulatory assist devices may have some role. To this end, the use of mechanical compression devices provides multiple patient- and provider-level benefits. This series provides a description of the use of the LUCAS mechanical CPR device and examples of coronary imaging and intervention during mechanical CPR.
- 1 February 2012
- Vol. 24 (2) , 79-83
Coronary imaging and intervention during cardiovascular collapse: use of the LUCAS mechanical CPR device in the cardiac catheterization laboratory.
The management of cardiac arrest during coronary angiography and intervention presents substantial challenges. Patients presenting with ST-segment elevation myocardial infarction or following resuscitation from cardiac arrest are at greatest risk and may represent a significant portion of patients in some centers. Timely and effective cardiopulmonary resuscitation (CPR), with manual chest compressions is the primary mode of support though novel circulatory assist devices may have some role. To this end, the use of mechanical compression devices provides multiple patient- and provider-level benefits. This series provides a description of the use of the LUCAS mechanical CPR device and examples of coronary imaging and intervention during mechanical CPR.
- 1 August 2010
- Vol. 22 (8) , 360-4
Use of a percutaneous left ventricular assist device for high-risk cardiac interventions and cardiogenic shock.
We sought to describe the use of the TandemHeart percutaneous left ventricular assist device (PVAD) in a group of high-risk patients undergoing complex cardiovascular procedures. There is a substantial risk of acute decompensation and death in patients with cardiogenic shock or a reduced cardiac reserve undergoing high-risk cardiovascular interventions. The TandemHeart PVAD provides near-total hemodynamic support in this setting. Thirty-seven high-risk patients underwent placement of the TandemHeart PVAD during 38 separate procedures between April 2007 and April 2009. PVAD insertion was considered emergent if a patient was not expected to survive more than 6 hours without PVAD support. Technical success was defined as successful initiation of the PVAD and completion of the intended interventional procedure. All 37 patients were in cardiogenic shock or undergoing complex coronary and valvular interventions with a high probability of hemodynamic collapse. The mean (+/- standard deviation) patient age was 73 +/- 14 years; 97% were in either NYHA class III-IV heart failure or cardiogenic shock; and the mean EuroSCORE was 11 +/- 3.4. Indications for ventricular assist device placement included critical aortic stenosis (n = 8), severe left main coronary stenosis (n = 18), severe multivessel coronary stenosis (n = 19) and severe cardiomyopathy (n = 23). Four patients were being managed for fulminant myocarditis, ventricular free-wall rupture, flail mitral valve or severe paravalvular leak. Despite their critical status and frequent (82%) need for post-procedure blood transfusion, this complex and high-risk patient population tolerated PVAD-supported intervention well and technical success was achieved in all patients. Seventy-one percent of patients survived to hospital discharge with improved functional status. Most deaths occurred in patients not expected to survive due to their moribund status and multiorgan failure. This experience demonstrates the utility and effectiveness of TandemHeart PVAD support in patients with advanced disease, critical clinical status and limited therapeutic options.
- 1 August 2010
- Vol. 22 (8) , 360-4
Use of a percutaneous left ventricular assist device for high-risk cardiac interventions and cardiogenic shock.
We sought to describe the use of the TandemHeart percutaneous left ventricular assist device (PVAD) in a group of high-risk patients undergoing complex cardiovascular procedures. There is a substantial risk of acute decompensation and death in patients with cardiogenic shock or a reduced cardiac reserve undergoing high-risk cardiovascular interventions. The TandemHeart PVAD provides near-total hemodynamic support in this setting. Thirty-seven high-risk patients underwent placement of the TandemHeart PVAD during 38 separate procedures between April 2007 and April 2009. PVAD insertion was considered emergent if a patient was not expected to survive more than 6 hours without PVAD support. Technical success was defined as successful initiation of the PVAD and completion of the intended interventional procedure. All 37 patients were in cardiogenic shock or undergoing complex coronary and valvular interventions with a high probability of hemodynamic collapse. The mean (+/- standard deviation) patient age was 73 +/- 14 years; 97% were in either NYHA class III-IV heart failure or cardiogenic shock; and the mean EuroSCORE was 11 +/- 3.4. Indications for ventricular assist device placement included critical aortic stenosis (n = 8), severe left main coronary stenosis (n = 18), severe multivessel coronary stenosis (n = 19) and severe cardiomyopathy (n = 23). Four patients were being managed for fulminant myocarditis, ventricular free-wall rupture, flail mitral valve or severe paravalvular leak. Despite their critical status and frequent (82%) need for post-procedure blood transfusion, this complex and high-risk patient population tolerated PVAD-supported intervention well and technical success was achieved in all patients. Seventy-one percent of patients survived to hospital discharge with improved functional status. Most deaths occurred in patients not expected to survive due to their moribund status and multiorgan failure. This experience demonstrates the utility and effectiveness of TandemHeart PVAD support in patients with advanced disease, critical clinical status and limited therapeutic options.