GMGerard Macias

Gerard Macias

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gerard Macias has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Whisky tasting using a bimetallic nanoplasmonic tongue

    by Gerard Macias, Justin R. Sperling, William J. Peveler, Glenn A. Burley, Steven L. Neale, Alasdair W. Clark

    In this paper, we present a bimetallic nanoplasmonic tongue capable of distinguishing between a variety of commercial whiskies.


  • Open Access

    Multilayered Nanoplasmonic Arrays for Self-Referenced Biosensing

    by Justin R. Sperling, Gerard Macias, Steven L. Neale, Alasdair W. Clark

    Nanostructured sensors based on localized surface plasmon resonance (LSPR) offer a number of advantages over other optical sensing technologies, making them excellent candidates for miniaturized, label-free chemical and biological detection. Highly sensitive to local refractive index changes, the resonance peaks of the nanosensors shift by different amounts when subject to different biological and chemical environments. Modifications to the nanostructure surface allow for the detection of specific molecules and chemicals with shifts so sensitive that the presence of single molecules can be detected. However, this extreme sensitivity has its drawbacks. Resonance shifts also occur because of temperature shifts, light-intensity fluctuations, and other environmental factors. To distinguish detection from drift, a secondary sensor region is often required. This often doubles the size of the device, requires two light sources and detectors (or complex optics), doubles the sample volume required (which may be expensive, or may not be possible if the sample quantity is limited), and subjects the reference to potential biofouling. Here, we present a new proof-of-concept multilayered LSPR sensor design that incorporates both a sensing layer and an encapsulated reference layer within the same region. By doing so, we are able to monitor and correct for sensor drift without the need for a secondary reference channel. We demonstrate the suitability of this sensor for sucrose concentration measurements and for the detection of biotin–avidin interactions, while also showing that the sensor can self-correct for drift. We believe that this multilayer sensor design holds promise for point-of-care diagnostics.


  • Open Access

    Reversible DNA micro-patterning using the fluorous effect

    by Gabriella E. Flynn, Jamie M. Withers, Gerard Macias, Justin R. Sperling, Sarah L. Henry, Jonathan M. Cooper, Glenn A. Burley, Alasdair W. Clark

    We describe a new method for the immobilisation of DNA into defined patterns with sub-micron resolution, using the fluorous effect. The method is fully reversible via a simple solvent wash, allowing the patterning, regeneration and re-patterning of surfaces with no degradation in binding efficiency following multiple removal/attachment cycles of different DNA sequences.


  • Surface roughness boosts the SERS performance of imprinted plasmonic architectures

    by Gerard Macias, María Alba, Lluís F. Marsal, Agustín Mihi

    Rough 2D plasmonic crystals pose as inexpensive and easily processed SERS substrates exhibiting enhancement factors up to 1.6 × 1010.


  • Effect of pore diameter in nanoporous anodic alumina optical biosensors

    by G. Macias, J. Ferré-Borrull, J. Pallarès, L. F. Marsal

    The influence of pore diameter over the optical response of nanoporous anodic alumina (NAA) films is analyzed by reflectance interference spectroscopy. NAA films manufactured by a two-step anodization procedure in oxalic acid exhibiting three well-defined pore diameter distributions with pores of 32 ± 4, 50 ± 3, and 73 ± 2 nm are studied. The optical detection of biomolecules is investigated by serially dosing protein A, human IgG and anti-human IgG into a nanoporous matrix using a custom-made flow cell. The results demonstrate that the transduction signal, the variation of effective optical thickness upon IgG binding to protein A (ΔEOT), depends on the nanopore diameter: for small pore diameter (32 nm) no significant differences in signals are observed for different protein concentrations whereas for larger pore diameters (50 nm and 73 nm) the signals increase for increasing concentrations from 10 to 100 μg mL−1. Our experiments also show that this signal can be further enhanced by amplification with anti-human IgG due to the multiple binding events between the antigen and the antibody. These results will enable the development of more sensitive interferometric biosensors based on NAA.


  • Protein attachment to nanoporous anodic alumina for biotechnological applications: Influence of pore size, protein size and functionalization path

    by Malgorzata Baranowska, Agata J. Slota, Pinkie J. Eravuchira, Gerard Macias, Elisabet Xifré-Pérez, Josep Pallares, Josep Ferré-Borrull, Lluís F. Marsal


  • Open Access

    Engineering optical properties of gold-coated nanoporous anodic alumina for biosensing

    by Laura P Hernández-Eguía, Josep Ferré-Borrull, Gerard Macias, Josep Pallarès, Lluís F Marsal

    The effect in the Fabry-Pérot optical interferences of nanoporous anodic alumina films coated with gold is studied as a function of the porosity and of the gold thickness by means of reflectance spectroscopy. Samples with porosities between 14 and 70% and gold thicknesses (10 and 20 nm) were considered. The sputtering of gold on the nanoporous anodic alumina (NAA) films results in an increase of the fringe intensity of the oscillations in the spectra resulting from Fabry-Pérot interferences in the porous layer, with a reduction in the maximum reflectance in the UV-visible region. For the thicker gold layer, sharp valleys appear in the near-infrared (IR) range that can be useful for accurate spectral shift measurements in optical biosensing. A theoretical model for the optical behavior has also been proposed. The model shows a very good agreement with the experimental measurements, what makes it useful for design and optimization of devices based on this material. This material capability is enormous for using it as an accurate and sensitive optical sensor, since gold owns a well-known surface chemistry with certain molecules, most of them biomolecules.


  • Open Access

    Nanostructural Engineering of Nanoporous Anodic Alumina for Biosensing Applications

    by Josep Ferré-Borrull, Josep Pallarès, Gerard Macías, Lluis F. Marsal

    Modifying the diameter of the pores in nanoporous anodic alumina opens new possibilities in the application of this material. In this work, we review the different nanoengineering methods by classifying them into two kinds: in situ and ex situ. Ex situ methods imply the interruption of the anodization process and the addition of intermediate steps, while in situ methods aim at realizing the in-depth pore modulation by continuous changes in the anodization conditions. Ex situ methods permit a greater versatility in the pore geometry, while in situ methods are simpler and adequate for repeated cycles. As an example of ex situ methods, we analyze the effect of changing drastically one of the anodization parameters (anodization voltage, electrolyte composition or concentration). We also introduce in situ methods to obtain distributed Bragg reflectors or rugate filters in nanoporous anodic alumina with cyclic anodization voltage or current. This nanopore engineering permits us to propose new applications in the field of biosensing: using the unique reflectance or photoluminescence properties of the material to obtain photonic barcodes, applying a gold-coated double-layer nanoporous alumina to design a self-referencing protein sensor or giving a proof-of-concept of the refractive index sensing capabilities of nanoporous rugate filters.


  • Open Access

    1-D nanoporous anodic alumina rugate filters by means of small current variations for real-time sensing applications

    by Gerard Macias, Josep Ferré-Borrull, Josep Pallarès, Lluís F Marsal

    A rugate filter based on nanoporous anodic alumina was fabricated using an innovative sinusoidal current profile with small current variation. The resulting structure consisted of highly parallel pores with modulations of the pore diameter along the pore axis and with no branching. The effect of the period time and the pore widening post-treatment was studied. From reflectance measurements, it was seen that the position of the reflection band can be tuned by adjusting the period time and the width by pore-widening post-treatments. We tested one of the rugate filters by infiltrating the structure with EtOH and water in order to evaluate its sensing capabilities. This method allows the fabrication of complex in-depth modulated nanoporous anodic alumina structures that open up the possibility of new kinds of alumina-based optical sensing devices.


  • Gold-Coated Ordered Nanoporous Anodic Alumina Bilayers for Future Label-Free Interferometric Biosensors

    by Gerard Macias, Laura P. Hernández-Eguía, Josep Ferré-Borrull, Josep Pallares, Lluís F. Marsal

    A cost-effective label-free optical biosensor based on gold-coated self-ordered nanoporous anodic alumina bilayers is presented. The structure is formed by two uniform nanoporous layers of different porosity (i.e., a top layer with large pores and a bottom layer with smaller pores). Each layer presents uniform pore size, regular pore distribution, and regular diameter along its pore length. To increase and improve the output sensing signals, a thin gold layer on the top surface was deposited. The gold layer increases the refractive index contrast between the nanoporous alumina layer and the analytical aqueous solution, and it results in a greater contrast in the interferometric spectrum and a higher sensitivity of the structure. From this structurally engineered architecture, the resulting reflectivity spectrum shows a complex series of Fabry–Pérot interference fringes, which was analyzed by the reflective interferometric Fourier transform spectroscopy (RIFTS) method. To determine the performance of this structure for biosensing applications, we tested bovine serum albumin (BSA) as the target protein. The results show a significant enhancement of the RIFTS peak intensity and position when a gold layer is on the top surface.