MAMaurice Anidjar

Maurice Anidjar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maurice Anidjar has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accuracy of cognitive MRI-targeted biopsy in hitting prostate cancer-positive regions of interest

    by Yannick Cerantola, Eléonore Haberer, Jose Torres, Mona Alameldin, Samuel Aronson, Mark Levental, Franck Bladou, Maurice Anidjar

    Prostate cancer (PCa) diagnosis relies on clinical suspicion leading to systematic transrectal ultrasound-guided biopsy (TRUSGB). Multiparametric magnetic resonance imaging (mpMRI) allows for targeted biopsy of suspicious areas of the prostate instead of random 12-core biopsy. This method has been shown to be more accurate in detecting significant PCa. However, the precise spatial accuracy of cognitive targeting is unknown. Consecutive patients undergoing mpMRI-targeted TRUSGB with cognitive registration (MRTB-COG) followed by robot-assisted radical prostatectomy were included in the present analysis. The regions of interest (ROIs) involved by the index lesion reported on mpMRI were subsequently targeted by two experienced urologists using the cognitive approach. The 27 ROIs were used as spatial reference. Mapping on radical prostatectomy specimen was used as reference to determine true-positive mpMRI findings. Per core correlation analysis was performed. Forty patients were included. Overall, 40 index lesions involving 137 ROIs (mean ROIs per index lesion 3.43) were identified on MRI. After correlating these findings with final pathology, 117 ROIs (85 %) were considered as true-positive lesions. A total of 102 biopsy cores directed toward such true-positive ROIs were available for final analysis. Cognitive targeted biopsy hit the target in 82 % of the cases (84/102). The only identified risk factor for missing the target was an anterior situated ROI (p = 0.01). In experienced hands, cognitive MRTB-COG allows for an accuracy of 82 % in hitting the correct target, given that it is a true-positive lesion. Anterior tumors are less likely to be successfully targeted.


  • A Combination of Hemostatic Agents May Safely Replace Deep Medullary Suture during Laparoscopic Partial Nephrectomy in a Pig Model

    by Guillaume Ploussard, Richard Haddad, Oleg Loutochin, Rahul Bera, Tatiana Cabrera, Nouf Malibari, Eleonora Scarlata, Vilma Derbekyan, Franck Bladou, Maurice Anidjar

    We assessed whether a combination of the fibrin tissue adhesive Tisseel® (human fibrinogen and thrombin) plus the hemostatic matrix FloSeal® (bovine derived gelatin matrix/human thrombin) could safely replace the conventional deep medullary suture without compromising outcomes. Laparoscopic mid pole and one-third partial nephrectomy was performed on the right kidney of 12 female pigs. The only difference between the 2 groups of 6 pigs each was the use of a fibrin tissue adhesive plus hemostatic matrix combination in group 2 instead of the deep medullary running suture in control group 1. Renal scans and angiograms were performed at baseline and before sacrifice at 5-week followup. Retrograde in vivo pyelogram was also done. No significant difference was seen in operative parameters or postoperative course between the groups. Renal scans revealed a statistically insignificant trend toward greater uptake loss in group 1 and angiograms showed 3 major vessel occlusions in that group. No active bleeding was detected. Those 3 kidneys had significantly poorer postoperative uptake on renal scan than that of other kidneys (18.6% vs 39.4%, p = 0.013). Only 1 small asymptomatic pseudoaneurysm was noted in group 1. No urine leakage was found in either group. No major vessel occlusion, pseudoaneurysm or urinary complications developed in group 2. Even after deep one-third partial nephrectomy FloSeal with concurrent Tisseel appeared sufficient to control major medullary vascular injuries and replace the deep medullary conventional suture without compromising operative outcomes. The potential advantages seen during functional and vascular examinations by decreasing the risk of unnecessary segmental vessel occlusion need further clinical evaluation.


    • 1 January 2012
      • Vol. 9  (4) , 629-38

    Percutaneous radiofrequency ablation of small renal tumors using CT-guidance: a review and its current role.

    by Richard L Haddad, Manish I Patel, Philip Vladica, Wassim Kassouf, Frank Bladou, Maurice Anidjar

    To provide key evidence-based strategies to improve outcomes of radiofrequency ablation and limit recurrences of small renal tumors. The literature was searched via OvidSP MEDLINE from 1997 to current using MeSH terms. All levels of evidence and types of reports were reviewed. We comprehensively reviewed technical issues, mechanisms, imaging criteria, ablative success, enhancement within one month, contraindications, oncological efficacy, morbidity rates, and follow-up strategies. The technique is safe and effective. Tumors < 2.5 cm are statistically most likely to remain disease-free. Anterior tumors are contraindicated. Strict follow-up is needed to detect failures, most of which occur within 3 months and can be easily salvaged with repeat radiofrequency ablation. Homogeneous enhancement within 1 month is not necessarily a failure, and tends to disappear after 4 to 6 weeks. Multi-disciplinary meetings must occur to discuss each case prior to treatment.