DWDa-Jiang Wang

Da-Jiang Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Da-Jiang Wang has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Eye Movement Variations in Indoor, Outdoor, and Reading Scenarios and Their Implications for Myopia

    by Qi Li, Chao Zhou, Tingting Liu, Yingxiang Han, Zengsheng Chen, Dajiang Wang, Xiaofei Wang

    Background and Aims: To quantitatively measure eye movement behaviors in indoor, outdoor, and reading scenarios to understand their potential link to myopia. Methods: Forty‐one healthy adult subjects freely viewed indoor and outdoor scenes and performed reading activities using virtual reality (VR). Eye movement data were recorded with the built‐in eye tracker of the VR headset (HTC Vive Pro Eye). Gaze and fixation data were calculated and reported for eight regions of the visual field. Results: Indoor scenes exhibited a more pronounced downward gaze than outdoor environments. Significant differences ( p < 0.05) in gaze and fixation behaviors were observed between reading and other scenarios. In Region 8 (peripheral inferior visual field), the median (1st quartile and 3rd quartile) number of gaze points was 816 (463, 1175), 1123 (743, 1497), and 1705 (966, 2382) for outdoor, indoor, and reading scenarios, respectively. Similarly, fixation behavior counts were 4 (1, 9), 7 (1, 11), and 39 (22, 54), respectively. Conclusion: Downward gaze and fixation behaviors are more prevalent in reading and indoor environments. Given that downward eye movements can induce instantaneous axial elongation, our results suggested a potential biomechanical pathway for myopia progression through optic nerve traction and ocular tissue remodeling. This study underscores the need for further research to explore the specific role of eye movement behaviors in the progression of myopia, especially in real‐life settings.


  • Open Access

    Human subcortical pathways automatically detect collision trajectory without attention and awareness

    by Fanhua Guo, Jinyou Zou, Ye Wang, Boyan Fang, Huanfen Zhou, Dajiang Wang, Sheng He, Peng Zhang

    Detecting imminent collisions is essential for survival. Here, we used high-resolution fMRI at 7 Tesla to investigate the role of attention and consciousness for detecting collision trajectory in human subcortical pathways. Healthy participants can precisely discriminate collision from near-miss trajectory of an approaching object, with pupil size change reflecting collision sensitivity. Subcortical pathways from the superior colliculus (SC) to the ventromedial pulvinar (vmPul) and ventral tegmental area (VTA) exhibited collision-sensitive responses even when participants were not paying attention to the looming stimuli. For hemianopic patients with unilateral lesions of the geniculostriate pathway, the ipsilesional SC and VTA showed significant activation to collision stimuli in their scotoma. Furthermore, stronger SC responses predicted better behavioral performance in collision detection even in the absence of awareness. Therefore, human tectofugal pathways could automatically detect collision trajectories without the observers’ attention to and awareness of looming stimuli, supporting “blindsight” detection of impending visual threats.


  • Open Access

    Human subcortical pathways automatically detect collision trajectory without attention and awareness

    by Fanhua Guo, Jinyou Zou, Ye Wang, Boyan Fang, Huafen Zhou, Dajiang Wang, Sheng He, Peng Zhang

    Detecting imminent collisions is essential for our survival and is likely supported by evolutionarily conserved mechanisms in the brain. Using high-resolution 7T fMRI, we investigated subcortical pathways for detecting collision trajectories in healthy human subjects and hemianopic patients. When healthy participants focused their attention on a central fixation task, their superior colliculus (SC), ventromedial pulvinar (vmPul) and ventral tegmental area (VTA) elicited stronger responses to a peripheral object approaching on head-collision courses compared to near-miss trajectories. Correlation and path analyses of collision-sensitive responses revealed collision sensitivity in the SC-vmPul and SC-VTA pathways without attention and cortical influence. Both behavioral performance and SC responses showed higher sensitivity to looming stimuli from the upper visual field. For hemianopic patients with unilateral lesions of the geniculostriate pathway, the ipsilesional SC, vmPul and VTA showed collision sensitivity to looming stimuli in their blind visual field, in the absence of their awareness. Stronger responses in the SC were also associated with better detection performance of the collision events. These findings clearly demonstrate that human tectofugal pathways, without attention and awareness, automatically detects approaching objects on a collision course, supporting blindsight to impending visual threats. Highlights SC-vmPul and SC-VTA pathways show collision sensitivity without attention and cortical influence in healthy participants. Both behavioral performance and SC responses show higher sensitivity to looming stimuli from the upper visual field. The ipsilesional SC, vmPul and VTA of hemianopic patients automatically detects collision trajectories in their blind visual field without awareness. SC response is associated with “blindsight” detection of impending collisions.

  • Open Access

    Outcomes of chronic angle-closure glaucoma treated by phacoemulsification and endocyclophotocoagulation with or without endoscopically goniosynechialysis

    by Xing Wu, Xi Liu, Zhao-Hui Li, Li-Qin Deng, Dai-Shi Chen, Da-Jiang Wang, Ying Wang

    To investigate the surgical outcomes of patients with chronic angle-closure glaucoma (CACG) treated with phacoemulsification (phaco)/endocyclophotocoagulation (ECP) with and without endoscopic goniosynechialysis (E-GSL). A retrospective, nonrandomized, comparative case series was conducted. Patients with CACG who underwent phaco in combination with either ECP alone (ECP group) or GSL with ECP (E-GSL group) from 2018 to 2019 were followed for 12mo and reviewed. Clinical features and outcomes were identified and analyzed. The ECP and E-GSL groups were matched in age and baseline intraocular pressure (IOP). Changes in IOP, mean of visual acuity (VA), peripheral anterior synechiae (PAS) formation, and the number of glaucoma medications was examined. The ECP group included 32 eyes of 27 patients, and the E-GSL group included 32 eyes of 26 patients. The preoperative baseline IOP was 22.18±6.48 mm Hg in the ECP group and 22.95±6.71 mm Hg in the E-GSL group (P=0.644). The mean IOP reduction was 26.2% in the ECP group and 41.6% in the E-GSL group at 12mo. The mean postoperative VA (logMAR units) at 12mo was 0.47 in the ECP group and 0.36 in the E-GSL group. The reduction in PAS formation and the number of glaucoma medications was also higher in the ECP group than E-GSL group at 12mo. The phaco/ECP and phaco/E-GSL groups both achieve a significant reduction in IOP without complications associated with traditional glaucoma filtration surgeries.


  • Open Access

    Artificial Intelligence Model for Antiinterference Cataract Automatic Diagnosis: A Diagnostic Accuracy Study

    by Xing Wu, Di Xu, Tong Ma, Zhao Hui Li, Zi Ye, Fei Wang, Xiang Yang Gao, Bin Wang, Yu Zhong Chen, Zhao Hui Wang, et al.

    Background: Cataract is the leading cause of blindness worldwide. In order to achieve large-scale cataract screening and remarkable performance, several studies have applied artificial intelligence (AI) to cataract detection based on fundus images. However, the fundus images they used are original from normal optical circumstances, which is less impractical due to the existence of poor-quality fundus images for inappropriate optical conditions in actual scenarios. Furthermore, these poor-quality images are easily mistaken as cataracts because both show fuzzy imaging characteristics, which may decline the performance of cataract detection. Therefore, we aimed to develop and validate an antiinterference AI model for rapid and efficient diagnosis based on fundus images.Materials and Methods: The datasets (including both cataract and noncataract labels) were derived from the Chinese PLA general hospital. The antiinterference AI model consisted of two AI submodules, a quality recognition model for cataract labeling and a convolutional neural networks-based model for cataract classification. The quality recognition model was performed to distinguish poor-quality images from normal-quality images and further generate the pseudo labels related to image quality for noncataract. Through this, the original binary-class label (cataract and noncataract) was adjusted to three categories (cataract, noncataract with normal-quality images, and noncataract with poor-quality images), which could be used to guide the model to distinguish cataract from suspected cataract fundus images. In the cataract classification stage, the convolutional-neural-network-based model was proposed to classify cataracts based on the label of the previous stage. The performance of the model was internally validated and externally tested in real-world settings, and the evaluation indicators included area under the receiver operating curve (AUC), accuracy (ACC), sensitivity (SEN), and specificity (SPE).Results: In the internal and external validation, the antiinterference AI model showed robust performance in cataract diagnosis (three classifications with AUCs >91%, ACCs >84%, SENs >71%, and SPEs >89%). Compared with the model that was trained on the binary-class label, the antiinterference cataract model improved its performance by 10%.Conclusion: We proposed an efficient antiinterference AI model for cataract diagnosis, which could achieve accurate cataract screening even with the interference of poor-quality images and help the government formulate a more accurate aid policy.


    • 1 January 2018
      • Vol. 11  (11) , 5171-+

    Comparison of human retinal progenitor cells cultured in media with or without serum: in vitro and in vivo characteristics and retinal transplantation

    by Linghui Qu, Xin Jin, Nan Chen, Dajiang Wang

    Retinal progenitor cells (RPCs) have a potential role in the treatment of retinal degenerative diseases. This study is to investigate in vitro and in vivo characteristics and retinal transplantation of RPCs cultured in media with or without serum. Progenitor cells obtained from the neural retina of human eyes at 6-16 weeks gestation were cultured in serum-free media (SF-hRPCs) or in media containing 10% FBS (S-hRPCs). The differences were characterized between the cells cultured in vitro and transplanted (retinal transplantation) into Royal College of Surgeons (RCS) rats. The functional status of the rats was examined by flash-electroretinogram recordings. The result was that S-hRPCs exhibited higher proliferative dynamics in vitro. On the basis of outer nuclear layer thickness and flash-electroretinograms, S-hRPCs were more efficacious in slowing the progression of retinal degeneration following transplantation compared with SF-hRPCs. Moreover, retinal mesenchymal-like stem cells were isolated and identified from the SF-hRPCs cultures. Our study demonstrated the potential of retinal MSCs for the treatment of retinal degeneration.


  • Long-term outcomes and complications of Moscow Eye Microsurgery Complex in Russia (MICOF) keratoprosthesis following ocular surface burns: clinical experience in China

    by Liqiang Wang, Yifei Huang, Gaiping Du, Ying Dong, Huiling Guo, Dajiang Wang, Jifeng Yu, Qun Wang, Bing Chen, Lulu Hou

    Objective The aim of this study was to evaluate the clinical outcomes of the implantation of MICOF keratoprosthesis (Kpro) in patients with alkaline, acid and thermal ocular burns. Methods This is a retrospective, non-competitive, interventional case series. Ninety eyes of 90 patients with ocular burns underwent MICOF KPro surgery at the Chinese People’s Liberation Army General Hospital between April 2000 and December 2012. Preoperative and postoperative findings were recorded. Retention of the prostheses and the treatment for postoperative complications were investigated. Results The mean age of patients was 40.26±12.18 years (range: 8–64 years), and the mean duration after ocular trauma was 4.8±6.2 years (range: 1.5–12 years). The mean follow-up period was 58.22±36.28 months (range: 1–145 months). Eighty patients were followed for ≥1 year and 73 eyes (81.11%) achieved the best-corrected visual acuity of 20/200 or better and 39 eyes (43.33%) achieved best-corrected visual acuity of ≥20/40. The common complications were glaucoma, corneal melt and conjunctiva overgrowth, and the incidences of these complications were 59.99%, 40% and 31.11%, respectively. One patient experienced KPro extrusion, and two patients exhibited leakage from the area of the implant. Seven with endophthalmitis eyes had final visual acuities of light perception. There was no significant difference in the effectiveness of the implants among the different causes of injuries, including acid, alkali and thermal burns. Conclusions MICOF Kpro is an effective alternative for patients with ocular burn with corneal blindness. Glaucoma and endophthalmitis were identified as significant risk factors for visual loss.


  • Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open‐angle glaucoma and normal eyes

    by Lei Tian, Dajiang Wang, Ying Wu, Xiaoli Meng, Bing Chen, Mei Ge, Yifei Huang

    Purpose: To evaluate the biomechanical properties of the cornea using Corneal Visualization Scheimpflug Technology (CorVis ST, Oculus) in eyes with primary open‐angle glaucoma (POAG) and normal control eyes.Methods: A comparative cross‐sectional study that included 42 patients with POAG and 60 normal control subjects matched for intraocular pressure (IOP) and central corneal thickness (CCT). IOP was measured with a Goldmann applanation tonometer (GAT). Corneal tomography and biomechanical parameters were measured with Pentacam (Oculus) and CorVis ST, respectively. Corneal biomechanical properties were compared between groups, and the associations between corneal biomechanical parameters and ocular characteristics were evaluated. Receiver operating characteristic (ROC) curves were used to establish a cut‐off value for the biomechanical parameters.Results: The following parameters of the CorVis ST showed a significant difference between eyes with POAG and normal eyes: first applanation velocity (Vin), second applanation time (A‐time2), peak distance (PD) and deformation amplitude (DA). In the univariate analysis, DA was negatively correlated with IOP in both groups. For all biomechanical parameters, the areas under the ROC curve were in, longer A‐time2, lower DA and longer PD than do IOP‐ and CCT‐matched normal control eyes. The biomechanical parameters of the CorVis ST cannot readily be used for diagnosis of POAG in the individual patient.


  • Effectiveness of Transscleral Cyclophotocoagulation as Adjuvant Therapy for Refractory Glaucoma in Keratoprosthesis Patients

    by Dajiang Wang, Jifeng Yu, Lei Tian, Liqiang Wang, Yifei Huang

    Purpose: To evaluate the efficacy and safety of diode laser transscleral cyclophotocoagulation (DLTSC) as an adjuvant therapy to treat refractory glaucoma diagnosed before or after Moscow Eye Microsurgery Complex (MICOF) keratoprosthesis surgery. Methods: Fifteen patients underwent unilateral DLTSC to treat refractory glaucoma diagnosed before or after undergoing MICOF keratoprosthesis surgery. The cause for keratoprosthesis was alkali burn in 8 patients (53.33%); thermal burn, sulfuric acid burn, and Steven-Johnson syndrome in 2 patients (13.33%) each; and ocular cicatricial pemphigoid in 1 patient (6.67%). Best-corrected visual acuity (BCVA), intraocular pressure (IOP), any medications, and adverse events were recorded before DLTSC and on postoperative day 7; months 1, 3, and 6; and every 6 months afterwards. Results: The patients were followed up for an average of 13.15 ± 9.35 months. The IOP was significantly less at postoperative months 6, 12, 24, and 36. There were no changes in BCVA after DLTSC. No significant changes in medication to treat ocular hypertension were prescribed. Conclusions: Diode laser transscleral cyclophotocoagulation is an effective treatment option for refractory glaucoma and can be used as a therapy adjuvant to keratoprosthesis. Long-term effects require further clinical observation.