Aleksei A. Anisimov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aleksei A. Anisimov has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Timofey V. Sergeev
Institute of Experimental Medicine
14 shared publications - Zafar Mukhamedovich Yuldashev
Saint Petersburg Electrotechnical University "LETI
7 shared publications Alena I. Skorobogatova
Saint Petersburg Electrotechnical University «LETI»,Department of Bioengineering Systems,St. Petersburg,Russia
5 shared publications- Elizaveta A. Agapova
Institute of Experimental Medicine
4 shared publications Anastasiya D. Sutyagina
Saint Petersburg Electrotechnical University "LETI",Department of Biomedical Engineering,St. Petersburg,Russia
3 shared publicationsAnastasiya Sutyagina
Department of Biomedical Engineering, Saint Petersburg Electrotechnical University “LETI”, Saint Petersburg, Russia
3 shared publications
Latest Publications
- 1 January 2025
- Published by Publishing house "Radiotekhnika" in Biomedical Radioelectronics
- p. 80-84
Development of an algorithm for assessing baroreflex sensitivity for early diagnosis of hypertension
Prolonged arterial hypertension leads to the development of serious diseases such as heart failure and coronary artery disease. In the absence of pathologies, the baroreflective mechanism is used for short-term and long-term regulation of blood pressure, however, a decrease in baroreceptor sensitivity can lead to chronic sympathetic hyperactivation and, as a result, to the development of hypertension, which, in the absence of proper treatment, can enter a resistive phase. Therefore, early diagnosis of decreased sensitivity of baroreflex can significantly help in preventing the development of hypertension and concomitant cardiovascular diseases. The aim of the study is to develop an algorithm for assessing the sensitivity of baroreflex, which will help identify early-stage disorders in baroreflex function and, with proper therapy, prevent the development of hypertension. An algorithm for assessing the sensitivity of arterial baroreflex was developed using a regression model and spectral analysis methods, and the algorithm was tested using a database of long-term recordings of electrocardiogram signals, shock values of blood pressure and cardiac output. The developed algorithm is used in studies of the regulatory mechanisms of central hemodynamics at the Laboratory of Physiology of Bioadministration of the I.P. Pavlov Physiological Department at the Institute of Experimental Medicine, St. Petersburg.
- 1 January 2025
- Published by Publishing house "Radiotekhnika" in Biomedical Radioelectronics
- p. 80-84
Development of an algorithm for assessing baroreflex sensitivity for early diagnosis of hypertension
Prolonged arterial hypertension leads to the development of serious diseases such as heart failure and coronary artery disease. In the absence of pathologies, the baroreflective mechanism is used for short-term and long-term regulation of blood pressure, however, a decrease in baroreceptor sensitivity can lead to chronic sympathetic hyperactivation and, as a result, to the development of hypertension, which, in the absence of proper treatment, can enter a resistive phase. Therefore, early diagnosis of decreased sensitivity of baroreflex can significantly help in preventing the development of hypertension and concomitant cardiovascular diseases. The aim of the study is to develop an algorithm for assessing the sensitivity of baroreflex, which will help identify early-stage disorders in baroreflex function and, with proper therapy, prevent the development of hypertension. An algorithm for assessing the sensitivity of arterial baroreflex was developed using a regression model and spectral analysis methods, and the algorithm was tested using a database of long-term recordings of electrocardiogram signals, shock values of blood pressure and cardiac output. The developed algorithm is used in studies of the regulatory mechanisms of central hemodynamics at the Laboratory of Physiology of Bioadministration of the I.P. Pavlov Physiological Department at the Institute of Experimental Medicine, St. Petersburg.
- 12 December 2022
- Published by ECO-Vector LLC in Medical academic journal
- Vol. 22 (3) , 73-89
Wobbling passive dynamic postural impacts as a promising method of increasing adaptive potential and improving cardiorespiratory system function
BACKGROUND: Passive postural exertions are used to assess orthostatic tolerance, adaptation to antiorthostatic stress and to identify the physiological effects of prolonged supine. As it was shown earlier, Wobbling Passive Dynamic Postural impacts influence on the state of functional reserves, activating long-term regulatory systems. AIM: The purpose of paper is comparative study of the dynamics of functional indices and calculated physiological indices before and after Wobbling Passive Dynamic Postural exertions and experimental hypokinesia. MATERIALS AND METHODS: The study involved 50 conditionally healthy subjects randomly divided into two groups at a ratio of 3 to 1. The first group (38 of participants) was exposed to the Wobbling Passive Dynamic Postural impacts. The subjects were in supine position for 5 minutes and then were rotated using an automatic turntable for 10 minutes, after which they were to horizontal position for 5 minutes. The angle deflection of the turntable during the Wobbling Passive Dynamic Postural impacts was from 5 to 15 degrees above or below from the base line. The subjects of the second group (12 of participants) were supine on the turntable fixed in the horizontal position for 20 minutes, thus being exposed to voluntary experimental hypokinesia. Anthropometric indices of subjects were measured before the study; functional indices were recorded continuously throughout the test. The entire study was divided into three stages, for which the values of the calculated physiological indices were presented as averages. Statistical analysis of the differences between the measured and calculated indices was performed using nonparametric statistical tests. RESULTS: Application of both types of exertions leads to decrease of the experienced stress and more effective blood circulation, but there are expressed differences. Thus, Wobbling Passive Dynamic Postural impacts are accompanied by a decrease in heart rate, an increase in the adaptive potential, an increase in endurance, which is confirmed by statistically significant changes in the analyzed indices. On the contrary, in the voluntary experimental hypokinesia group, by the end of the 20-minute motionless lying there was a gradual increase in heart rate, decrease in endurance indices and weakening of the adaptive potential. CONCLUSIONS: The results obtained with the use of available, previously tested, physiological techniques permit to recommend wobbling passive dynamic postural impacts as a promising method for preventing the harmful effect of hypokinesia. An advanced study of changes in the microvasculature using modern equipment based on Laser Doppler flowmetry will allow verifying the obtained results.
- 12 December 2022
- Published by ECO-Vector LLC in Medical academic journal
- Vol. 22 (3) , 73-89
Wobbling passive dynamic postural impacts as a promising method of increasing adaptive potential and improving cardiorespiratory system function
BACKGROUND: Passive postural exertions are used to assess orthostatic tolerance, adaptation to antiorthostatic stress and to identify the physiological effects of prolonged supine. As it was shown earlier, Wobbling Passive Dynamic Postural impacts influence on the state of functional reserves, activating long-term regulatory systems. AIM: The purpose of paper is comparative study of the dynamics of functional indices and calculated physiological indices before and after Wobbling Passive Dynamic Postural exertions and experimental hypokinesia. MATERIALS AND METHODS: The study involved 50 conditionally healthy subjects randomly divided into two groups at a ratio of 3 to 1. The first group (38 of participants) was exposed to the Wobbling Passive Dynamic Postural impacts. The subjects were in supine position for 5 minutes and then were rotated using an automatic turntable for 10 minutes, after which they were to horizontal position for 5 minutes. The angle deflection of the turntable during the Wobbling Passive Dynamic Postural impacts was from 5 to 15 degrees above or below from the base line. The subjects of the second group (12 of participants) were supine on the turntable fixed in the horizontal position for 20 minutes, thus being exposed to voluntary experimental hypokinesia. Anthropometric indices of subjects were measured before the study; functional indices were recorded continuously throughout the test. The entire study was divided into three stages, for which the values of the calculated physiological indices were presented as averages. Statistical analysis of the differences between the measured and calculated indices was performed using nonparametric statistical tests. RESULTS: Application of both types of exertions leads to decrease of the experienced stress and more effective blood circulation, but there are expressed differences. Thus, Wobbling Passive Dynamic Postural impacts are accompanied by a decrease in heart rate, an increase in the adaptive potential, an increase in endurance, which is confirmed by statistically significant changes in the analyzed indices. On the contrary, in the voluntary experimental hypokinesia group, by the end of the 20-minute motionless lying there was a gradual increase in heart rate, decrease in endurance indices and weakening of the adaptive potential. CONCLUSIONS: The results obtained with the use of available, previously tested, physiological techniques permit to recommend wobbling passive dynamic postural impacts as a promising method for preventing the harmful effect of hypokinesia. An advanced study of changes in the microvasculature using modern equipment based on Laser Doppler flowmetry will allow verifying the obtained results.
- Open Access
- 1 August 2022
- Published by MDPI AG in Electronics
- Vol. 11 (15) , 2402
Evolution of Bioamplifiers: From Vacuum Tubes to Highly Integrated Analog Front-Ends
The past century has seen the ongoing development of amplifiers for different electrophysiological signals to study the work of the heart. Since the vacuum tube era, engineers and designers of bioamplifiers for recording electrophysiological signals have been trying to achieve similar objectives: increasing the input impedance and common-mode rejection ratio, as well as reducing power consumption and the size of the bioamplifier. This review traces the evolution of bioamplifiers, starting from circuits on vacuum tubes and discrete transistors through circuits on operational and instrumental amplifiers, and to combined analog-digital solutions on analog front-end integrated circuits. Examples of circuits and their technical features are provided for each stage of the bioamplifier development. Special emphasis is placed on the review of modern analog front-end solutions for biopotential registration, including their generalized structural diagram and table of comparative characteristics. A detailed review of analog front-end circuit integration in various practical applications is provided, with examples of the latest achievements in the field of electrocardiogram, electroencephalogram, and electromyogram registration. The review concludes with key points and insights for the future development of the analog front-end concept applied to bioelectric signal registration.
- 1 August 2022
- Published by MDPI AG in Electronics
- Vol. 11 (15) , 2402
Open AccessEvolution of Bioamplifiers: From Vacuum Tubes to Highly Integrated Analog Front-Ends
The past century has seen the ongoing development of amplifiers for different electrophysiological signals to study the work of the heart. Since the vacuum tube era, engineers and designers of bioamplifiers for recording electrophysiological signals have been trying to achieve similar objectives: increasing the input impedance and common-mode rejection ratio, as well as reducing power consumption and the size of the bioamplifier. This review traces the evolution of bioamplifiers, starting from circuits on vacuum tubes and discrete transistors through circuits on operational and instrumental amplifiers, and to combined analog-digital solutions on analog front-end integrated circuits. Examples of circuits and their technical features are provided for each stage of the bioamplifier development. Special emphasis is placed on the review of modern analog front-end solutions for biopotential registration, including their generalized structural diagram and table of comparative characteristics. A detailed review of analog front-end circuit integration in various practical applications is provided, with examples of the latest achievements in the field of electrocardiogram, electroencephalogram, and electromyogram registration. The review concludes with key points and insights for the future development of the analog front-end concept applied to bioelectric signal registration.
- 1 January 2022
- Published by Springer Nature
- p. 103-110
Development of Simple Model of the Arterial Baroreflex
- 1 January 2022
- Published by Springer Nature
- p. 103-110
Development of Simple Model of the Arterial Baroreflex
- Open Access
- 15 December 2021
- Published by ECO-Vector LLC in Medical academic journal
- Vol. 21 (4) , 31-46
Multiparameter study of the physiological reactions of the human organism to complex postural loads
BACKGROUND: Reactions of human cardiovascular system to complex dynamic postural loads were under investigation by previous authors. Individual limiting mode of postural loads, i.e. alternating negative-positive periodic changes of body position angle on tilting table with regard to clinostatic position, was defined. It was demonstrated that application of oscillatory passive dynamic postural loads can cause certain hemodynamic reactions, which expression depend on postural loads dynamic characteristics and subjects primary state. AIM: Aim of the study is to develop comprehensive methodology (practice) that explores regulation mechanisms of cardiovascular, respiratory, central and autonomic nervous systems and their reactions to physiological strains with assigned properties (intensity, direction, periodicity and duration of postural loads). MATERIALS AND METHODS: 30 young healthy participants took part in the study. Physiological indicators were registered in dynamic mode synchronously with trajectory of participants motion. This study implemented common statistical methods as much as original means of analysis by integrating theory of dynamic systems. RESULTS: Evaluation of synchronously registered physiological indicators by means of instrumental and software application, in particular, postural loads protocols of various intensity and motion direction, showed that oscillatory passive dynamic postural mode allows considerable improvements in overall blood circulation and gas exchange in the lungs. These changes constitute in a rise of systemic and local blood flow without significant shift of arterial pressure, increased frequency of heartbeats and respiratory rate. CONCLUSIONS: Continuous monitoring of participants condition during complex postural loads give an opportunity for studying a set of physiological reactions and has a future implication in scientifically approved recommendations that describe practical use of postural loads as a correction technology for human health state and training.
- 15 December 2021
- Published by ECO-Vector LLC in Medical academic journal
- Vol. 21 (4) , 31-46
Open AccessMultiparameter study of the physiological reactions of the human organism to complex postural loads
BACKGROUND: Reactions of human cardiovascular system to complex dynamic postural loads were under investigation by previous authors. Individual limiting mode of postural loads, i.e. alternating negative-positive periodic changes of body position angle on tilting table with regard to clinostatic position, was defined. It was demonstrated that application of oscillatory passive dynamic postural loads can cause certain hemodynamic reactions, which expression depend on postural loads dynamic characteristics and subjects primary state. AIM: Aim of the study is to develop comprehensive methodology (practice) that explores regulation mechanisms of cardiovascular, respiratory, central and autonomic nervous systems and their reactions to physiological strains with assigned properties (intensity, direction, periodicity and duration of postural loads). MATERIALS AND METHODS: 30 young healthy participants took part in the study. Physiological indicators were registered in dynamic mode synchronously with trajectory of participants motion. This study implemented common statistical methods as much as original means of analysis by integrating theory of dynamic systems. RESULTS: Evaluation of synchronously registered physiological indicators by means of instrumental and software application, in particular, postural loads protocols of various intensity and motion direction, showed that oscillatory passive dynamic postural mode allows considerable improvements in overall blood circulation and gas exchange in the lungs. These changes constitute in a rise of systemic and local blood flow without significant shift of arterial pressure, increased frequency of heartbeats and respiratory rate. CONCLUSIONS: Continuous monitoring of participants condition during complex postural loads give an opportunity for studying a set of physiological reactions and has a future implication in scientifically approved recommendations that describe practical use of postural loads as a correction technology for human health state and training.
- Open Access
High Precision Human Skin Temperature Fluctuations Measuring Instrument
This paper describes the experimental results of testing a prototype of a high precision human skin rapid temperature fluctuations measuring instrument. Based on the author’s work, an original circuit solution on a miniature semiconductor diode sensor has been designed. The proposed circuitry provides operation in the full voltage range with automatic setting and holding the operating point, as well as the necessary slope of the conversion coefficient (up to 2300 mV/°C), which makes it possible to register fast temperature oscillations from the surface of the human body and other biological objects. Simulation results in the Microcap 12 software and laboratory tests have confirmed all declared design specifications: temperature resolution of 0.01 °C, transducer thermal time constant of 0.05 s. An original thermostat and an experimental setup for the simultaneous registration of the electrocardiogram, pulse wave signals from the Biopac polygraph MP36 and a signal of temperature oscillations from the prototype thermometer have been designed for further investigations. The preliminary test results indicates that using the designed measuring instrument gives a possibility to provide an in-depth study of the relationship between micro- and macro-blood circulations manifested in skin temperature fluctuations.
Open AccessHigh Precision Human Skin Temperature Fluctuations Measuring Instrument
This paper describes the experimental results of testing a prototype of a high precision human skin rapid temperature fluctuations measuring instrument. Based on the author’s work, an original circuit solution on a miniature semiconductor diode sensor has been designed. The proposed circuitry provides operation in the full voltage range with automatic setting and holding the operating point, as well as the necessary slope of the conversion coefficient (up to 2300 mV/°C), which makes it possible to register fast temperature oscillations from the surface of the human body and other biological objects. Simulation results in the Microcap 12 software and laboratory tests have confirmed all declared design specifications: temperature resolution of 0.01 °C, transducer thermal time constant of 0.05 s. An original thermostat and an experimental setup for the simultaneous registration of the electrocardiogram, pulse wave signals from the Biopac polygraph MP36 and a signal of temperature oscillations from the prototype thermometer have been designed for further investigations. The preliminary test results indicates that using the designed measuring instrument gives a possibility to provide an in-depth study of the relationship between micro- and macro-blood circulations manifested in skin temperature fluctuations.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1713-1717
Baroreflex Function Analysis for Assessing the Cardiovascular System's Health
To monitor the heart muscle state and assess the risks of heart disease, the researchers need a lot of information. Recording functional indicators of autonomic heart rate control can provide a significant amount of valuable data. These indicators include, for example, the amount of respiratory arrhythmia or the relationship between baroreflex and heart rate. It is believed that a decrease in the influence of these factors on the heart rate indicates a reduction in the" internal reserves" of the body and can predict the upcoming development of heart diseases. In this study, we propose an algorithm for processing the baroreflex function to assess the cardiovascular system's health.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1713-1717
Baroreflex Function Analysis for Assessing the Cardiovascular System's Health
To monitor the heart muscle state and assess the risks of heart disease, the researchers need a lot of information. Recording functional indicators of autonomic heart rate control can provide a significant amount of valuable data. These indicators include, for example, the amount of respiratory arrhythmia or the relationship between baroreflex and heart rate. It is believed that a decrease in the influence of these factors on the heart rate indicates a reduction in the" internal reserves" of the body and can predict the upcoming development of heart diseases. In this study, we propose an algorithm for processing the baroreflex function to assess the cardiovascular system's health.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1718-1721
System for Recording Continuous Blood Pressure and Heart Rate for Baroreflex Studying
A system for studying baroreflex has been developed. The algorithm for the joint analysis of signals of continuous arterial blood pressure (APB) and heart rate is the basis for creating the system. Beat-to-beat ABP is recorded using the pulse wave propagation time. It is defined as the difference between the moment of the cardiac cycle (according to the ECG signal) and the moment of the pulse wave arrival (according to the PPG signal). Baroreflex is assessed by comparing the phase relationships between the pulsed arterial pressure and heart rate signals in the standard heart rate frequency ranges (HF, LF, VLF). Frequency processing in these ranges is performed by using digital filtering. Examples of recorded signals and their comparison are presented.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1718-1721
System for Recording Continuous Blood Pressure and Heart Rate for Baroreflex Studying
A system for studying baroreflex has been developed. The algorithm for the joint analysis of signals of continuous arterial blood pressure (APB) and heart rate is the basis for creating the system. Beat-to-beat ABP is recorded using the pulse wave propagation time. It is defined as the difference between the moment of the cardiac cycle (according to the ECG signal) and the moment of the pulse wave arrival (according to the PPG signal). Baroreflex is assessed by comparing the phase relationships between the pulsed arterial pressure and heart rate signals in the standard heart rate frequency ranges (HF, LF, VLF). Frequency processing in these ranges is performed by using digital filtering. Examples of recorded signals and their comparison are presented.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1865-1868
Algorithm for Analysis of the Correlation Between the Exposure to Functional Tests and the Dynamics of the Heart Rate
Assessment of the impact of external conditions and controlled exposures on the indicators of the cardiovascular system functioning remains a current problem in the study of the mechanisms of regulation of the human body. In this paper, time-synchronized recordings of the heart rate dynamics and a physical quantity reflecting the controlled exposure to functional tests – postural loads – are considered. An algorithm for analyzing the relationship between the exposure to functional tests on the example of postural loads and heart rate dynamics is proposed. The algorithm allows to analyze Spearman's correlation coefficients between time-synchronized records of changes in the duration of cardio intervals and records of the dynamics of a physical quantity reflecting the intensity of exposure. By presenting the same exposure at regular intervals we studied the effect of adaptation of the cardiovascular system to the exposure as the effect of habituation to the exposure and reducing the body's response when repeating homogeneous exposures.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1865-1868
Algorithm for Analysis of the Correlation Between the Exposure to Functional Tests and the Dynamics of the Heart Rate
Assessment of the impact of external conditions and controlled exposures on the indicators of the cardiovascular system functioning remains a current problem in the study of the mechanisms of regulation of the human body. In this paper, time-synchronized recordings of the heart rate dynamics and a physical quantity reflecting the controlled exposure to functional tests – postural loads – are considered. An algorithm for analyzing the relationship between the exposure to functional tests on the example of postural loads and heart rate dynamics is proposed. The algorithm allows to analyze Spearman's correlation coefficients between time-synchronized records of changes in the duration of cardio intervals and records of the dynamics of a physical quantity reflecting the intensity of exposure. By presenting the same exposure at regular intervals we studied the effect of adaptation of the cardiovascular system to the exposure as the effect of habituation to the exposure and reducing the body's response when repeating homogeneous exposures.