Tianning Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tianning Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Yan Li
School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba, Australia
8 shared publications - Thomas Schmierer
University of Southern Queensland, Toowoomba, QLD, Australia
3 shared publications - Jee Sook Ra
School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba, QLD 4350, Australia
2 shared publications - Xiaohui Tao
University of Southern Queensland, Toowoomba, Australia
2 shared publications - Di Wu
La Trobe University
1 shared publication - Jee Sook Ra
School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba, QLD, Australia
1 shared publication
Latest Publications
- Open Access
- 17 March 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 7 (2) , 1-24
Loss of Consciousness Early Warning Modelling with EEG Signals
An accurate Depth of Anaesthesia (DoA) assessment is crucial for enhancing a patient’s surgical experience, as it helps avoid intraoperative (anaesthesia) awareness and reduces postoperative recovery time and cognitive dysfunction. This article presents two novel research outcomes. The first is the development of a new DoA index using processed Electroencephalogram (EEG) signals and machine learning techniques. This research uniquely combines powerful features extracted by two distinct time series decomposition methods: the Fast Fourier Transform (FFT) and Variation Mode Decomposition (VMD). Permutation Entropy, Multiscale (Permutation) Lempel–Ziv Complexity, Hjorth’s mobility and Petrosian Fractal Dimension features trained a Support Vector Regressor producing a highly responsive DoA index of 85.8% accuracy. Secondly, a novel fixed-period Loss of Consciousness (LoC) early warning system is developed. Using the same feature set, a KNeighbors (KNN) classifier achieves an accuracy and Area Under the Receiver Operating Characteristic Curve of 82% after Synthetic Minority Oversampling Technique (SMOTE) dataset imbalance correction. The KNN model outperforms Decision Trees, Random Forests and Support Vector classification. Reliably predicting the LoC within a fixed period would greatly assist medical practitioners by ensuring an appropriate level of anaesthetic is administered to achieve the LoC, thus reducing the risk of anaesthesia awareness and preventing anaesthetic overdose.
- 17 March 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 7 (2) , 1-24
Open AccessLoss of Consciousness Early Warning Modelling with EEG Signals
An accurate Depth of Anaesthesia (DoA) assessment is crucial for enhancing a patient’s surgical experience, as it helps avoid intraoperative (anaesthesia) awareness and reduces postoperative recovery time and cognitive dysfunction. This article presents two novel research outcomes. The first is the development of a new DoA index using processed Electroencephalogram (EEG) signals and machine learning techniques. This research uniquely combines powerful features extracted by two distinct time series decomposition methods: the Fast Fourier Transform (FFT) and Variation Mode Decomposition (VMD). Permutation Entropy, Multiscale (Permutation) Lempel–Ziv Complexity, Hjorth’s mobility and Petrosian Fractal Dimension features trained a Support Vector Regressor producing a highly responsive DoA index of 85.8% accuracy. Secondly, a novel fixed-period Loss of Consciousness (LoC) early warning system is developed. Using the same feature set, a KNeighbors (KNN) classifier achieves an accuracy and Area Under the Receiver Operating Characteristic Curve of 82% after Synthetic Minority Oversampling Technique (SMOTE) dataset imbalance correction. The KNN model outperforms Decision Trees, Random Forests and Support Vector classification. Reliably predicting the LoC within a fixed period would greatly assist medical practitioners by ensuring an appropriate level of anaesthetic is administered to achieve the LoC, thus reducing the risk of anaesthesia awareness and preventing anaesthetic overdose.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
Prediction of Anesthesia Depth and Early Detection of State Transitions Using EEG-Derived Features
EEG-based depth of anesthesia (DoA) instrumentation facilitates the measurement of consciousness levels during surgical procedures; critical for patient safety and optimal anesthetic delivery. Existing instrumentation systems are limited by providing only retrospective DoA measurement and lack predictive measurement tools or early warning functions. This constrains their value during dynamic intraoperative events such as loss of consciousness (LoC) and recovery of consciousness (RoC), where timely adjustment of anesthetic delivery is crucial. To address this need, this study presents a prediction and early warning measurement system, named DoA-PrEWS. This framework integrates EEG-derived features with machine learning for DoA measurement at current and future time intervals. This framework extends to provide specialized measurement around the detection and prediction of transitional events. The framework comprises five components: DoA-Current-GPR, a Gaussian process regression model for measuring current DoA levels; DoA-State-BEM, a bagged ensemble model for anesthetic state classification; DoA-Transition-RF, a random forest model for classifying DoA state transition moments; DoA-TTT-NN, a neural network for measuring Time To Transition events; and DoA-Future-GPR, a GPR model for DoA prediction. Evaluated on EEG data from 120 surgical patients and benchmarked against the Bispectral Index (BIS), DoA-Current-GPR achieved a correlation of 0.85 (RMSE = 11.22), and DoA-Future-GPR predicted DoA 120 seconds ahead with a correlation of 0.78. DoA-Transition-RF detected loss of consciousness (LoC) and recovery of consciousness (RoC) with accuracies of 95.14% and 83.75%, respectively, while DoA-TTT-NN predicted time to transition with correlations of 0.81 (LoC) and 0.72 (RoC). Performance was consistent across demographic groups, surgical types, anesthetic agents, and under variable signal quality conditions. External validation using an independent UniSQ dataset yielded consistent results, supporting cross-institution generalizability. End-to-end inference latency was approximately 29.7 ms per window, indicating compatibility with real-time clinical deployment. These results demonstrate the feasibility of a unified DoA system for the detection of current and future consciousness levels. This work highlights the clinical value of improving intraoperative measurement to ensure responsiveness in managing anesthetic state transitions.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
Prediction of Anesthesia Depth and Early Detection of State Transitions Using EEG-Derived Features
EEG-based depth of anesthesia (DoA) instrumentation facilitates the measurement of consciousness levels during surgical procedures; critical for patient safety and optimal anesthetic delivery. Existing instrumentation systems are limited by providing only retrospective DoA measurement and lack predictive measurement tools or early warning functions. This constrains their value during dynamic intraoperative events such as loss of consciousness (LoC) and recovery of consciousness (RoC), where timely adjustment of anesthetic delivery is crucial. To address this need, this study presents a prediction and early warning measurement system, named DoA-PrEWS. This framework integrates EEG-derived features with machine learning for DoA measurement at current and future time intervals. This framework extends to provide specialized measurement around the detection and prediction of transitional events. The framework comprises five components: DoA-Current-GPR, a Gaussian process regression model for measuring current DoA levels; DoA-State-BEM, a bagged ensemble model for anesthetic state classification; DoA-Transition-RF, a random forest model for classifying DoA state transition moments; DoA-TTT-NN, a neural network for measuring Time To Transition events; and DoA-Future-GPR, a GPR model for DoA prediction. Evaluated on EEG data from 120 surgical patients and benchmarked against the Bispectral Index (BIS), DoA-Current-GPR achieved a correlation of 0.85 (RMSE = 11.22), and DoA-Future-GPR predicted DoA 120 seconds ahead with a correlation of 0.78. DoA-Transition-RF detected loss of consciousness (LoC) and recovery of consciousness (RoC) with accuracies of 95.14% and 83.75%, respectively, while DoA-TTT-NN predicted time to transition with correlations of 0.81 (LoC) and 0.72 (RoC). Performance was consistent across demographic groups, surgical types, anesthetic agents, and under variable signal quality conditions. External validation using an independent UniSQ dataset yielded consistent results, supporting cross-institution generalizability. End-to-end inference latency was approximately 29.7 ms per window, indicating compatibility with real-time clinical deployment. These results demonstrate the feasibility of a unified DoA system for the detection of current and future consciousness levels. This work highlights the clinical value of improving intraoperative measurement to ensure responsiveness in managing anesthetic state transitions.
- Open Access
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 187684-187695
Epileptic Seizure Prediction Based on Synchroextracting Transform and Sparse Representation
Feature extraction is crucial in machine learning and EEG analysis, where raw data often contains excess information. The prominence of machine learning has led to the development of numerous feature extraction methods over the past decade. This paper introduces an efficient feature extraction method that demonstrates superior experimental results. We employed the Synchroextracting Transform (SET) and Sparse Representation (SR) for enhanced feature extraction in epileptic EEG analysis. SET is a recently developed signal transformation technique, and SR effectively extracts information from multi-dimensional data. Our goal is to enhance time-frequency (TF) resolution using the SET-SR method, which offers a TF representation more concentrated with energy than traditional TF analysis methods. SR decomposes SET multi-dimensional sub-signals to accurately predict epileptic seizures. The significance of this feature extraction method was evaluated using a k-Nearest Neighbor (k-NN) algorithm, a traditional machine learning technique. Applying the SET-SR with the k-NN, we achieved an average accuracy of 99.48% on the CHB-MIT database and 100% accuracy on the Bonn University database in classifying pre-seizure signals. The SET-SR effectively detects pre-seizure signals, showing promise for developing an efficient patient-specific seizure prediction algorithm based on EEG data. Our findings demonstrate that enhanced feature extraction can reliably identify pre-seizure signals with high precision, even when using classical machine learning methods like k-NN. This research underscores the importance of feature extraction in EEG signal analysis and suggests that diverse classification methods can be employed for real-time seizure prediction while maintaining high accuracy.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 187684-187695
Open AccessEpileptic Seizure Prediction Based on Synchroextracting Transform and Sparse Representation
Feature extraction is crucial in machine learning and EEG analysis, where raw data often contains excess information. The prominence of machine learning has led to the development of numerous feature extraction methods over the past decade. This paper introduces an efficient feature extraction method that demonstrates superior experimental results. We employed the Synchroextracting Transform (SET) and Sparse Representation (SR) for enhanced feature extraction in epileptic EEG analysis. SET is a recently developed signal transformation technique, and SR effectively extracts information from multi-dimensional data. Our goal is to enhance time-frequency (TF) resolution using the SET-SR method, which offers a TF representation more concentrated with energy than traditional TF analysis methods. SR decomposes SET multi-dimensional sub-signals to accurately predict epileptic seizures. The significance of this feature extraction method was evaluated using a k-Nearest Neighbor (k-NN) algorithm, a traditional machine learning technique. Applying the SET-SR with the k-NN, we achieved an average accuracy of 99.48% on the CHB-MIT database and 100% accuracy on the Bonn University database in classifying pre-seizure signals. The SET-SR effectively detects pre-seizure signals, showing promise for developing an efficient patient-specific seizure prediction algorithm based on EEG data. Our findings demonstrate that enhanced feature extraction can reliably identify pre-seizure signals with high precision, even when using classical machine learning methods like k-NN. This research underscores the importance of feature extraction in EEG signal analysis and suggests that diverse classification methods can be employed for real-time seizure prediction while maintaining high accuracy.
- Open Access
- 4 April 2024
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 151, 102869
Harnessing machine learning for EEG signal analysis: Innovations in depth of anaesthesia assessment
- 4 April 2024
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 151, 102869
Open AccessHarnessing machine learning for EEG signal analysis: Innovations in depth of anaesthesia assessment
- Open Access
- 18 June 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 240, 107678
A novel epileptic seizure prediction method based on synchroextracting transform and 1-dimensional convolutional neural network
- 18 June 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 240, 107678
Open AccessA novel epileptic seizure prediction method based on synchroextracting transform and 1-dimensional convolutional neural network
- 26 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Convolutional Long Short-Term Memory-Based Neural Network for Epilepsy Detection From EEG
Epilepsy is a severe neurological disorder characterized by recurrent seizures, which increases the risk of death three times more than normal. Currently Electroencephalography (EEG) has emerged as a highly promising technique for the diagnosis of epilepsy. The majority of current EEG-based epilepsy detection research have employed a variety of deep learning-based models, but most of the approaches suffer from poor generalizability, optimal design and performance rates. To address these issues, this study aims to develop an efficient framework based on deep spatio-temporal neural network called convolutional long short-term memory (ConvLSTM) for epilepsy detection from EEG signals. In the proposed model, firstly standard 19 channel EEG data are selected and resampled at 256Hz, and then those signals are segmented into three-second time frames. Afterward, the segmented data are fed as input to the ConvLSTM model for identifying epileptic patients from normal subjects. To generalize the proposed model, we have tested it on two different datasets with varying population sizes. We have used the five-fold cross validation and leave-one-out cross validation schemes to eliminate the experiment’s biases. To further validate the proposed framework, we have carried out various ablation studies. The experimental results demonstrate that the proposed model outperforms the current state-of-the-art results for the studied datasets, making it suitable for use as an automated system for the diagnosis of epilepsy.
- 26 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Convolutional Long Short-Term Memory-Based Neural Network for Epilepsy Detection From EEG
Epilepsy is a severe neurological disorder characterized by recurrent seizures, which increases the risk of death three times more than normal. Currently Electroencephalography (EEG) has emerged as a highly promising technique for the diagnosis of epilepsy. The majority of current EEG-based epilepsy detection research have employed a variety of deep learning-based models, but most of the approaches suffer from poor generalizability, optimal design and performance rates. To address these issues, this study aims to develop an efficient framework based on deep spatio-temporal neural network called convolutional long short-term memory (ConvLSTM) for epilepsy detection from EEG signals. In the proposed model, firstly standard 19 channel EEG data are selected and resampled at 256Hz, and then those signals are segmented into three-second time frames. Afterward, the segmented data are fed as input to the ConvLSTM model for identifying epileptic patients from normal subjects. To generalize the proposed model, we have tested it on two different datasets with varying population sizes. We have used the five-fold cross validation and leave-one-out cross validation schemes to eliminate the experiment’s biases. To further validate the proposed framework, we have carried out various ablation studies. The experimental results demonstrate that the proposed model outperforms the current state-of-the-art results for the studied datasets, making it suitable for use as an automated system for the diagnosis of epilepsy.
- Open Access
- 6 June 2022
- Published by Springer Nature in Health Information Science and Systems
- Vol. 10 (1) , 1-14
A novel empirical wavelet SODP and spectral entropy based index for assessing the depth of anaesthesia
The requirement for anaesthesia during modern surgical procedures is unquestionable to ensure a safe experience for patients with successful recovery. Assessment of the depth of anaesthesia (DoA) is an important and ongoing field of research to ensure patient stability during and post-surgery. This research addresses the limitations of current DoA indexes by developing a new index based on electroencephalography (EEG) signal analysis. Empirical wavelet transformation (EWT) methods are employed to extract wavelet coefficients before statistical analysis. The features Spectral Entropy and Second Order Difference Plot are extracted from the wavelet coefficients. These features are used to train a new index, SSEDoA, utilising a Support Vector Machine (SVM) with a linear kernel function. The new index accurately assesses the DoA to illustrate the transition between different anaesthetic stages. Testing was undertaken with nine patients and an additional four patients with low signal quality. Across the nine patients we tested, an average correlation of 0.834 was observed with the Bispectral (BIS) index. The analysis of the DoA stage transition exhibited a Choen's Kappa of 0.809, indicative of a high agreement.
- 6 June 2022
- Published by Springer Nature in Health Information Science and Systems
- Vol. 10 (1) , 1-14
Open AccessA novel empirical wavelet SODP and spectral entropy based index for assessing the depth of anaesthesia
The requirement for anaesthesia during modern surgical procedures is unquestionable to ensure a safe experience for patients with successful recovery. Assessment of the depth of anaesthesia (DoA) is an important and ongoing field of research to ensure patient stability during and post-surgery. This research addresses the limitations of current DoA indexes by developing a new index based on electroencephalography (EEG) signal analysis. Empirical wavelet transformation (EWT) methods are employed to extract wavelet coefficients before statistical analysis. The features Spectral Entropy and Second Order Difference Plot are extracted from the wavelet coefficients. These features are used to train a new index, SSEDoA, utilising a Support Vector Machine (SVM) with a linear kernel function. The new index accurately assesses the DoA to illustrate the transition between different anaesthetic stages. Testing was undertaken with nine patients and an additional four patients with low signal quality. Across the nine patients we tested, an average correlation of 0.834 was observed with the Bispectral (BIS) index. The analysis of the DoA stage transition exhibited a Choen's Kappa of 0.809, indicative of a high agreement.
- Open Access
A Novel Permutation Entropy-Based EEG Channel Selection for Improving Epileptic Seizure Prediction
The key research aspects of detecting and predicting epileptic seizures using electroencephalography (EEG) signals are feature extraction and classification. This paper aims to develop a highly effective and accurate algorithm for seizure prediction. Efficient channel selection could be one of the solutions as it can decrease the computational loading significantly. In this research, we present a patient-specific optimization method for EEG channel selection based on permutation entropy (PE) values, employing K nearest neighbors (KNNs) combined with a genetic algorithm (GA) for epileptic seizure prediction. The classifier is the well-known support vector machine (SVM), and the CHB-MIT Scalp EEG Database is used in this research. The classification results from 22 patients using the channels selected to the patient show a high prediction rate (average 92.42%) compared to the SVM testing results with all channels (71.13%). On average, the accuracy, sensitivity, and specificity with selected channels are improved by 10.58%, 23.57%, and 5.56%, respectively. In addition, four patient cases validate over 90% accuracy, sensitivity, and specificity rates with just a few selected channels. The corresponding standard deviations are also smaller than those used by all channels, demonstrating that tailored channels are a robust way to optimize the seizure prediction.
Open AccessA Novel Permutation Entropy-Based EEG Channel Selection for Improving Epileptic Seizure Prediction
The key research aspects of detecting and predicting epileptic seizures using electroencephalography (EEG) signals are feature extraction and classification. This paper aims to develop a highly effective and accurate algorithm for seizure prediction. Efficient channel selection could be one of the solutions as it can decrease the computational loading significantly. In this research, we present a patient-specific optimization method for EEG channel selection based on permutation entropy (PE) values, employing K nearest neighbors (KNNs) combined with a genetic algorithm (GA) for epileptic seizure prediction. The classifier is the well-known support vector machine (SVM), and the CHB-MIT Scalp EEG Database is used in this research. The classification results from 22 patients using the channels selected to the patient show a high prediction rate (average 92.42%) compared to the SVM testing results with all channels (71.13%). On average, the accuracy, sensitivity, and specificity with selected channels are improved by 10.58%, 23.57%, and 5.56%, respectively. In addition, four patient cases validate over 90% accuracy, sensitivity, and specificity rates with just a few selected channels. The corresponding standard deviations are also smaller than those used by all channels, demonstrating that tailored channels are a robust way to optimize the seizure prediction.
- Open Access
- 5 December 2019
- Published by Springer Nature
- p. 244-253
Anesthesia Assessment Based on ICA Permutation Entropy Analysis of Two-Channel EEG Signals
- 5 December 2019
- Published by Springer Nature
- p. 244-253
Open AccessAnesthesia Assessment Based on ICA Permutation Entropy Analysis of Two-Channel EEG Signals
- Open Access
- 1 June 2014
- Published by Medknow in Asian Pacific Journal of Tropical Medicine
- Vol. 7 (6) , 429-437
Depth of anaesthesia monitors and the latest algorithms
This paper reviews the existing depth of anaesthesia (DoA) monitors and their algorithms and also proposes to improve their performance from four aspects. An ideal DoA monitor should be able to suggest a personalised drug dosage, to predict and provide early warnings when dosages are inappropriate, to be portable and highly cost-effective. The limitations of the existing DoA monitors commonly include unsatisfied data filtering techniques, time delay for the monitoring responses, and inflexible and low noise immunity problems. The latest research results show that their performance can be improved using up-to-date computing technology and neurophysiology. The findings in Chinese market review show that neither the imported nor the Chinese domestic DoA monitors are widely utilised at hospitals, but the demand for DoA monitors is very high. Clearly there is a high demand which encourages the development of a better DoA monitor and its mass production in China.
- 1 June 2014
- Published by Medknow in Asian Pacific Journal of Tropical Medicine
- Vol. 7 (6) , 429-437
Open AccessDepth of anaesthesia monitors and the latest algorithms
This paper reviews the existing depth of anaesthesia (DoA) monitors and their algorithms and also proposes to improve their performance from four aspects. An ideal DoA monitor should be able to suggest a personalised drug dosage, to predict and provide early warnings when dosages are inappropriate, to be portable and highly cost-effective. The limitations of the existing DoA monitors commonly include unsatisfied data filtering techniques, time delay for the monitoring responses, and inflexible and low noise immunity problems. The latest research results show that their performance can be improved using up-to-date computing technology and neurophysiology. The findings in Chinese market review show that neither the imported nor the Chinese domestic DoA monitors are widely utilised at hospitals, but the demand for DoA monitors is very high. Clearly there is a high demand which encourages the development of a better DoA monitor and its mass production in China.