Anton Khaplanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anton Khaplanov has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
B. Guerard
Institute Laue Langevin 71 avenue des Martyrs FR-38042 Grenoble France
4 shared publicationsC. Höglund
European Spallation Source P.O Box 176 SE-22100 Lund Sweden
4 shared publications- Francesco Piscitelli
European Spallation Source ERIC P.O. Box 176 SE-221 00 Lund Sweden
4 shared publications J. Birch
Thin Film Physics division Linköping University IFM SE-581 83 Linköping Sweden
4 shared publicationsJ. Jensen
Thin Film Physics division Linköping University IFM SE-581 83 Linköping Sweden
4 shared publicationsL. Hultman
Thin Film Physics division Linköping University IFM SE-581 83 Linköping Sweden
4 shared publications
Latest Publications
- Open Access
Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.Open AccessMulti-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the $^3$He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by $^3$He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS. - Open Access
- 1 April 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (04) , P04030
Multi-Grid detector for neutron spectroscopy: results obtained on time-of-flight spectrometer CNCS
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of 3 He detectors on an operational instrument. The demonstrator has an active area of 0.2 m 2. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the 3 He detectors simultaneously, showing that all features recorded by one 1Corresponding author.
- 1 April 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (04) , P04030
Open AccessMulti-Grid detector for neutron spectroscopy: results obtained on time-of-flight spectrometer CNCS
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of 3 He detectors on an operational instrument. The demonstrator has an active area of 0.2 m 2. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the 3 He detectors simultaneously, showing that all features recorded by one 1Corresponding author.
- 1 October 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (10) , P10019
Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
- 1 October 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (10) , P10019
Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
- Open Access
Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of of the Multi-Grid detector and other similar concepts due to its mechanical and neutronic properties. Due to natural concentration of $\alpha$ emitters, however, the background from $\alpha$ particles misidentified as neutrons can be unacceptably high. We present our experience operating a detector prototype affected by this issue. Monte Carlo simulations have been used to confirm the background as $\alpha$ particles. The issues have been addressed in the more recent implementations of the Multi-Grid detector by the use of purified aluminium as well as Ni-plating of standard aluminium. The result is the reduction in background by two orders of magnitude. A new large-area prototype has been built incorporating these modifications.Open AccessInvestigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of of the Multi-Grid detector and other similar concepts due to its mechanical and neutronic properties. Due to natural concentration of $\alpha$ emitters, however, the background from $\alpha$ particles misidentified as neutrons can be unacceptably high. We present our experience operating a detector prototype affected by this issue. Monte Carlo simulations have been used to confirm the background as $\alpha$ particles. The issues have been addressed in the more recent implementations of the Multi-Grid detector by the use of purified aluminium as well as Ni-plating of standard aluminium. The result is the reduction in background by two orders of magnitude. A new large-area prototype has been built incorporating these modifications. - Open Access
- 24 July 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 528 (1) , 012040
In-beam test of the Boron-10 Multi-Grid neutron detector at the IN6 time-of-flight spectrometer at the ILL
A neutron detector concept based on solid layers of boron carbide enriched in 10B has been in development for the last few years as an alternative for 3He by collaboration between the ILL, ESS and Linköping University. This Multi-Grid detector uses layers of aluminum substrates coated with 10B4C on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the 3He detectors of IN6 at ILL. The 10B detector has an active area of 32 x 48cm2. It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional 3He detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background.
- 24 July 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 528 (1) , 012040
Open AccessIn-beam test of the Boron-10 Multi-Grid neutron detector at the IN6 time-of-flight spectrometer at the ILL
A neutron detector concept based on solid layers of boron carbide enriched in 10B has been in development for the last few years as an alternative for 3He by collaboration between the ILL, ESS and Linköping University. This Multi-Grid detector uses layers of aluminum substrates coated with 10B4C on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the 3He detectors of IN6 at ILL. The 10B detector has an active area of 32 x 48cm2. It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional 3He detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background.
- 1 October 2013
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (10) , P10025
Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
- 1 October 2013
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (10) , P10025
Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
- Open Access
Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.
Open AccessInvestigation of gamma-ray sensitivity of neutron detectors based on thin converter films
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.