Maria J. Giráldez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Maria J. Giráldez has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Carlos García-Resúa
Departamento de Física Aplicada (área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
1 shared publication Eva Yebra-Pimentel
Department of Applied Physics - Optometry Group, University of Santiago de Compostela
1 shared publication- Hugo Pena-Verdeal
Applied Physics Department (Optometry Area), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, 15705 Santiago de Compostela, Spain
1 shared publication Jorge Gilino
Department of Applied Physics - Optometry Group, University of Santiago de Compostela
1 shared publicationSilvia García-Montero
Department of Applied Physics - Optometry Group, University of Santiago de Compostela
1 shared publication
Latest Publications
- Open Access
- 18 June 2014
- Published by PAGEPress Publications in Optometry Reports
- Vol. 4 (1)
Effect of lotrafilcon A silicone hydrogel contact lens on intraocular pressure measurement
The present paper aims to assess the effect of lotrafilcon A contact lenses (CL) in situ on intraocular pressure (IOP) measurement performed with three portable tonometers (ICare, Tonopen and Perkins). This cross-sectional study included thirty young healthy subjects. Intraocular pressure measurements without CL were performed first, followed by IOP measurements with CL for twenty minutes. ICare IOP measurements obtained with lotrafilcon A CL overestimated IOP values without CL by 1 mmHg (P<0.001). However, both techniques displayed close level of agreement (95% LoA, -4.17 to +1.63 mmHg). Also, differences between both methods tended not to increase (P=0.9). No significant differences were observed between IOP measurements without and with CL for Perkins (paired-t test, P=0.23) and Tonopen XL (pairedt test, P=0.17). In conclusion, adequate IOP measurements through zero power lotrafilcon A silicone hydrogel CL can be obtained with all three tonometers in healthy eyes, although, in case of ICare, the practitioner must be aware of the 1 mmHg overestimation with CL.
- 18 June 2014
- Published by PAGEPress Publications in Optometry Reports
- Vol. 4 (1)
Open AccessEffect of lotrafilcon A silicone hydrogel contact lens on intraocular pressure measurement
The present paper aims to assess the effect of lotrafilcon A contact lenses (CL) in situ on intraocular pressure (IOP) measurement performed with three portable tonometers (ICare, Tonopen and Perkins). This cross-sectional study included thirty young healthy subjects. Intraocular pressure measurements without CL were performed first, followed by IOP measurements with CL for twenty minutes. ICare IOP measurements obtained with lotrafilcon A CL overestimated IOP values without CL by 1 mmHg (P<0.001). However, both techniques displayed close level of agreement (95% LoA, -4.17 to +1.63 mmHg). Also, differences between both methods tended not to increase (P=0.9). No significant differences were observed between IOP measurements without and with CL for Perkins (paired-t test, P=0.23) and Tonopen XL (pairedt test, P=0.17). In conclusion, adequate IOP measurements through zero power lotrafilcon A silicone hydrogel CL can be obtained with all three tonometers in healthy eyes, although, in case of ICare, the practitioner must be aware of the 1 mmHg overestimation with CL.