Michal Bajcsy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Michal Bajcsy has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Rubayet Al Maruf
Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
6 shared publications- Alexander H. Xu
Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
3 shared publications Behrooz Semnani
Institute for Quantum Computing, University of Waterloo, Waterloo, Ontario, N2L3G1, Canada
3 shared publications- Liena Zaidan
Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
3 shared publications Michael Reimer
Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
3 shared publications- Mustafa Yavuz
Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
3 shared publications
Latest Publications
- Open Access
Boron-Nitride-Doped Graphene Oxide FETs for COVID-19 Detection: A Comparative Review Against Existing Market Solutions
COVID-19 point-of-care tests return results faster than centralized RT-PCR, but none combines high sensitivity, speed, low cost, and ease of use. This review compares a boron-nitride-doped graphene oxide (BN-GO) FET biosensor with commercial diagnostics and other graphene-based FET biosensors using LOD, PPA/NPA, detection time, cost, shelf life, and ease of use. Because the BN-GO platform is at technology readiness level 4 and has been tested only in buffer, the market comparison is treated as a gap analysis. The BN-GO FET biosensor showed promising early-stage analytical performance, responding rapidly to N-protein in buffer at its lowest tested concentration, below the detection limits of the other graphene FETs compared. However, the lowest-concentration response was obtained from an initial set of device tests. Future studies will assess the repeatability, reproducibility, clinical performance, and manufacturing scalability of the device. They will also focus on extending its shelf life, because the current estimate falls short of the WHO target product profile and would complicate stockpiling and distribution. The estimated cost per test is approximately the same as that of rapid antigen tests. These findings position the BN-GO FET biosensor as a promising next-generation candidate for point-of-care COVID-19 diagnostics if the remaining cost and shelf-life challenges are addressed.
Open AccessBoron-Nitride-Doped Graphene Oxide FETs for COVID-19 Detection: A Comparative Review Against Existing Market Solutions
COVID-19 point-of-care tests return results faster than centralized RT-PCR, but none combines high sensitivity, speed, low cost, and ease of use. This review compares a boron-nitride-doped graphene oxide (BN-GO) FET biosensor with commercial diagnostics and other graphene-based FET biosensors using LOD, PPA/NPA, detection time, cost, shelf life, and ease of use. Because the BN-GO platform is at technology readiness level 4 and has been tested only in buffer, the market comparison is treated as a gap analysis. The BN-GO FET biosensor showed promising early-stage analytical performance, responding rapidly to N-protein in buffer at its lowest tested concentration, below the detection limits of the other graphene FETs compared. However, the lowest-concentration response was obtained from an initial set of device tests. Future studies will assess the repeatability, reproducibility, clinical performance, and manufacturing scalability of the device. They will also focus on extending its shelf life, because the current estimate falls short of the WHO target product profile and would complicate stockpiling and distribution. The estimated cost per test is approximately the same as that of rapid antigen tests. These findings position the BN-GO FET biosensor as a promising next-generation candidate for point-of-care COVID-19 diagnostics if the remaining cost and shelf-life challenges are addressed.
- Open Access
- 12 August 2026
- Published by Springer Nature in npj Quantum Information
Photon subtraction using a three-level emitter coupled to a chiral waveguide
We propose a scheme for deterministic single photon subtraction based on Single Photon Raman Interaction (SPRINT) with a three-level quantum emitter coupled to a chiral waveguide and present an analytical and numerical study of its feasibility. We show that single photon subtraction probability for pulsed input light in a coherent or a Fock state can approach unity in the ideal limit and discuss the potential of various reported quantum emitter-waveguide platforms as candidates for experimental realization of our scheme. The use of chiral slow-light photonic crystal waveguides coupled to Λ -type emitters can perform efficient photon subtraction. While integrating cold atoms to such systems remains technically challenging, solid-state emitters offer a potentially practical path to realize such photon subtraction.
- 12 August 2026
- Published by Springer Nature in npj Quantum Information
Open AccessPhoton subtraction using a three-level emitter coupled to a chiral waveguide
We propose a scheme for deterministic single photon subtraction based on Single Photon Raman Interaction (SPRINT) with a three-level quantum emitter coupled to a chiral waveguide and present an analytical and numerical study of its feasibility. We show that single photon subtraction probability for pulsed input light in a coherent or a Fock state can approach unity in the ideal limit and discuss the potential of various reported quantum emitter-waveguide platforms as candidates for experimental realization of our scheme. The use of chiral slow-light photonic crystal waveguides coupled to Λ -type emitters can perform efficient photon subtraction. While integrating cold atoms to such systems remains technically challenging, solid-state emitters offer a potentially practical path to realize such photon subtraction.
- Open Access
Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli
Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
Open AccessRapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli
Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
- Open Access
- 24 June 2024
- Published by MDPI AG in Preprints.org
Rapid, Selective, and Ultra-Sensitive Electronic Field Effect Detection of Escherichia coli
We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field effect transistor (FET) biosensor with B/N co-coped graphene oxide (GO) gel (BN-GO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 minutes. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10– 108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-GO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
- 24 June 2024
- Published by MDPI AG in Preprints.org
Open AccessRapid, Selective, and Ultra-Sensitive Electronic Field Effect Detection of Escherichia coli
We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field effect transistor (FET) biosensor with B/N co-coped graphene oxide (GO) gel (BN-GO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 minutes. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10– 108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-GO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
- Open Access
- 28 November 2023
- Published by Springer Nature in Research Square
Widely tunable solid-state source of single-photons matching an atomic transition
Hybrid quantum technologies aim to combine diverse quantum systems, mirroring classical computers' integration of electronic, photonic, magnetic, and mechanical components. Quantum dots in semiconductor nanowires emit high-purity, deterministic single photons with high repetition, while atomic ensembles offer photon storage and strong optical nonlinearities controllable by single photons. To interface quantum dots with atomic ensembles successfully, precise optical frequency matching of these two platforms is crucial. We demonstrate a simple, precise, reversible, broad-range, and local method for controlling the emission frequency of individual quantum dots embedded in tapered semiconductor nanowires. We then interface the quantum dots with an atomic ensemble via single-photons matched to hyperfine transitions and slow-light regions of the cesium D1-line. Our approach allows linking atomic and solid-state quantum systems and can potentially also be applied to other types of nanowire-embedded solid-state emitters, as well as for creating devices based on multiple solid-state emitters tuned to produce indistinguishable photons.
- 28 November 2023
- Published by Springer Nature in Research Square
Open AccessWidely tunable solid-state source of single-photons matching an atomic transition
Hybrid quantum technologies aim to combine diverse quantum systems, mirroring classical computers' integration of electronic, photonic, magnetic, and mechanical components. Quantum dots in semiconductor nanowires emit high-purity, deterministic single photons with high repetition, while atomic ensembles offer photon storage and strong optical nonlinearities controllable by single photons. To interface quantum dots with atomic ensembles successfully, precise optical frequency matching of these two platforms is crucial. We demonstrate a simple, precise, reversible, broad-range, and local method for controlling the emission frequency of individual quantum dots embedded in tapered semiconductor nanowires. We then interface the quantum dots with an atomic ensemble via single-photons matched to hyperfine transitions and slow-light regions of the cesium D1-line. Our approach allows linking atomic and solid-state quantum systems and can potentially also be applied to other types of nanowire-embedded solid-state emitters, as well as for creating devices based on multiple solid-state emitters tuned to produce indistinguishable photons.
- Open Access
Detecting Single Microwave Photons with NV Centers in Diamond
We propose a scheme for detecting single microwave photons using dipole-induced transparency (DIT) in an optical cavity resonantly coupled to a spin-selective transition of a negatively charged nitrogen-vacancy (NV−) defect in diamond crystal lattices. In this scheme, the microwave photons control the interaction of the optical cavity with the NV− center by addressing the spin state of the defect. The spin, in turn, is measured with high fidelity by counting the number of reflected photons when the cavity is probed by resonant laser light. To evaluate the performance of the proposed scheme, we derive the governing master equation and solve it through both direct integration and the Monte Carlo approach. Using these numerical simulations, we then investigate the effects of different parameters on the detection performance and find their corresponding optimized values. Our results indicate that detection efficiencies approaching 90% and fidelities exceeding 90% could be achieved when using realistic optical and microwave cavity parameters.
Open AccessDetecting Single Microwave Photons with NV Centers in Diamond
We propose a scheme for detecting single microwave photons using dipole-induced transparency (DIT) in an optical cavity resonantly coupled to a spin-selective transition of a negatively charged nitrogen-vacancy (NV−) defect in diamond crystal lattices. In this scheme, the microwave photons control the interaction of the optical cavity with the NV− center by addressing the spin state of the defect. The spin, in turn, is measured with high fidelity by counting the number of reflected photons when the cavity is probed by resonant laser light. To evaluate the performance of the proposed scheme, we derive the governing master equation and solve it through both direct integration and the Monte Carlo approach. Using these numerical simulations, we then investigate the effects of different parameters on the detection performance and find their corresponding optimized values. Our results indicate that detection efficiencies approaching 90% and fidelities exceeding 90% could be achieved when using realistic optical and microwave cavity parameters.
- 1 January 2023
- Published by Optica Publishing Group
- p. JTh2A.7
Characterizing photon emission from a quantum dot excited by long above-band pulses
We experimentally investigate the quality of single photons produced with long-pulse above-band excitation of a quantum dot embedded in a semiconductor nanowire and model the results via rate equations and Markov-chains.
- 1 January 2023
- Published by Optica Publishing Group
- p. JTh2A.7
Characterizing photon emission from a quantum dot excited by long above-band pulses
We experimentally investigate the quality of single photons produced with long-pulse above-band excitation of a quantum dot embedded in a semiconductor nanowire and model the results via rate equations and Markov-chains.
- 15 June 2022
- Published by Morressier GmbH
Diffraction gratings for atom cooling produced by direct laser writing
We report the use of a direct laser-writing process to fabricate a 2D diffraction grating that can form a magneto-optical trap from a single lase |
- 15 June 2022
- Published by Morressier GmbH
Diffraction gratings for atom cooling produced by direct laser writing
We report the use of a direct laser-writing process to fabricate a 2D diffraction grating that can form a magneto-optical trap from a single lase |
- 1 January 2022
- Published by Optica Publishing Group
- p. JW3B.65
A compact setup for broadband polarization tomography
We describe an automated setup for broadband polarization tomography that can be used for measuring birefringence and chirality of metasurfaces, photonic crystal slabs, and other complex optical elements.
- 1 January 2022
- Published by Optica Publishing Group
- p. JW3B.65
A compact setup for broadband polarization tomography
We describe an automated setup for broadband polarization tomography that can be used for measuring birefringence and chirality of metasurfaces, photonic crystal slabs, and other complex optical elements.
- 1 January 2021
- Published by Optica Publishing Group
- p. JTu3A.54
Generating single photon pulses from a quantum dot using a continuous wave laser and an electro-optic modulator
We report the generation of single-photon pulses from an InAsP quantum dot utilizing a CW diode laser and a fiber electro-optic modulator as a pump in lieu of a pulsed picosecond Ti;Sapphire laser.
- 1 January 2021
- Published by Optica Publishing Group
- p. JTu3A.54
Generating single photon pulses from a quantum dot using a continuous wave laser and an electro-optic modulator
We report the generation of single-photon pulses from an InAsP quantum dot utilizing a CW diode laser and a fiber electro-optic modulator as a pump in lieu of a pulsed picosecond Ti;Sapphire laser.