MCMaurice Chiron

Maurice Chiron

*This is an algorithmically generated author record based on publicly available information.

Maurice Chiron has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Ali Assad

    Commissariat à l Énergie Atomique, DRN/DMT/SERMA/LEPP 91191 Gif-sur-Yvette, France

    2 shared publications
  • Jean Claude Nimal

    Commissariat à l Énergie Atomique, DRN/DMT/SERMA/LEPP 91191 Gif-sur-Yvette, France

    2 shared publications
  • Cheikh M’bAcké Diop

    Commissariat à l’Énergie Atomique DRN/DMT/SERMA/LEPP, 91191 Gif-sur-Yvette, France

    1 shared publication
  • Cheikh M’backé Diop

    Commissariat à l Énergie Atomique, DRN/DMT/SERMA/LEPP 91191 Gif-sur-Yvette, France

    1 shared publication
  • Philippe Ridoux

    Électricité de France EDF-SEPTEN, 69628 Villeurbanne, France

    1 shared publication

Latest Publications

  • Open Access

    A Comparison of Gamma-Ray Buildup Factors for Water, Iron and Lead using Discrete Ordinates, Moments, and Monte Carlo Methods

    by Ali Assad, Maurice Chiron, Jean Claude Nimal, Cheikh M’backé Diop

    The aim of this study is to compare point isotropic buildup factors recently calculated by Sn discrete ordinate codes with those obtained by the EGS4 Monte Carlo code and those of the standard data (ANS-6.4.3-1991). The comparisons are presented for the water, iron, and lead exposure buildup factors, for 3 energies of 10, 1, and 0.1 MeV, and for total thicknesses of up to 30 mfp mean free paths. The comparisons have shown that the buildup factors calculated by the Sn and EGS4 codes are in very good agreement. The maximum deviations observed between the results given by these codes are about 10% for all cases. The deviations between the Sn and EGS4 codes on the one hand, and the standard data on the other hand, are about 35% and 20% for the lead exposure buildup factors at 10 MeV and 0.1 MeV respectively. In the second part of the study we show the impact of both coherent and incoherent scattering on the exposure and the exposure buildup factors. These effects are important for the energy range below 1 MeV and must not be neglected in the transport calculations.


  • Open Access

    General Formalism for Calculating Gamma-Ray Buildup Factors in Multilayer Shields into MERCURE-6 Code

    by Ali Assad, Maurice Chiron, Jean Claude Nimal, Cheikh M’bAcké Diop, Philippe Ridoux

    This study proposes a new method for calculating gamma-ray buildup factors in multilayer shields. The formula combines the buildup of single-layer shields with products and quotients. The tests have shown that the approximating formula reproduces the reference data of double layer shields very well for most cases. With the same parameters and with a new physical consideration that takes into account in a global way the degradation of the gamma-ray energy spectrum, the buildup factors of three and five layer shields were also very well reproduced. The new formula is incorporated in the new version of the MERCURE-6 point-kernel code.