Jang-Lyul Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jang-Lyul Kim has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
A.S. Pradhan
1 shared publicationB H Kim
Health Physics Department, Korea Atomic Energy Research Institute, Taejon, Korea
1 shared publicationB.H. Kim
1 shared publicationBong-Hwan Kim
Health Physics Dept., Korea Atomic Energy Research Institute P.O.Box, Yuseong, Taejon, Korea
1 shared publicationH.S. Choe
1 shared publicationJ K Lee
Health Physics Department, Korea Atomic Energy Research Institute, Taejon, Korea
1 shared publication
Latest Publications
- 1 April 2007
- Published by Elsevier in Radiation Measurements
- Vol. 42 (4-5) , 597-600
Dual-step thermal treatment for the stability of glow curve structure and the TL sensitivity of the newly developed LiF:Mg,Cu,Si
- 1 April 2007
- Published by Elsevier in Radiation Measurements
- Vol. 42 (4-5) , 597-600
Dual-step thermal treatment for the stability of glow curve structure and the TL sensitivity of the newly developed LiF:Mg,Cu,Si
- Open Access
- 1 March 2000
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 37 (sup1) , 771-775
Measurements of Monochromatic Fluorescence X-ray Spectra
A personal dosimetry system is required to measure the personal dose equivalent in a wide range of radiation fields as accurately as possible. For the construction of complete response functions of a dosemeter, varieties of monochromatic photon field covering energy ranges encountered in radiation protection practices are needed. So, 8 different qualities of monochromatic fluorescence X-rays whose energy, ranging from 8.6 keV to 75 keV are produced using the combination of an X-ray generator and a series of radiators emitting monochromatic K-X-rays. The Kβ lines are discriminated by appropriate filter to make the Kα X-rays dominate the spectra. The resulting spectra are verified by spectrometry with a HPGe planar detector and an MCA. The measured spectra show nearly monoenergy peaks and the beam purities are from 89.7 to 97.5 % for all the energy qualities. The effects of tube currents on spectral purity at the determined X-ray tube potential are not observed up to 15 mA.
- 1 March 2000
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 37 (sup1) , 771-775
Open AccessMeasurements of Monochromatic Fluorescence X-ray Spectra
A personal dosimetry system is required to measure the personal dose equivalent in a wide range of radiation fields as accurately as possible. For the construction of complete response functions of a dosemeter, varieties of monochromatic photon field covering energy ranges encountered in radiation protection practices are needed. So, 8 different qualities of monochromatic fluorescence X-rays whose energy, ranging from 8.6 keV to 75 keV are produced using the combination of an X-ray generator and a series of radiators emitting monochromatic K-X-rays. The Kβ lines are discriminated by appropriate filter to make the Kα X-rays dominate the spectra. The resulting spectra are verified by spectrometry with a HPGe planar detector and an MCA. The measured spectra show nearly monoenergy peaks and the beam purities are from 89.7 to 97.5 % for all the energy qualities. The effects of tube currents on spectral purity at the determined X-ray tube potential are not observed up to 15 mA.
- 1 December 1997
- Published by American Chemical Society (ACS) in Environmental Health Perspectives
- Vol. 105 (suppl 6) , 1417-1421
Establishment of ANSI N13.11 X-ray radiation fields for personal dosimetry performance test by computation and experiment.
This paper describes establishment by computational and experimental methods of the American National Standard Institute (ANSI) N13.11 X-ray radiation fields by the Korea Atomic Energy Research Institute (KAERI). These fields were used in the standard irradiations of various personal dosimeters for the personal dosimetry performance test program performed by the Ministry of Science and Technology of Korea in the autumn of 1995. Theoretical X-ray spectra produced from two KAERI X-ray generators were estimated using a modified Kramers' theory with target attenuation and backscatter correction and their spectral distributions experimentally measured by a high-purity germanium semiconductor detector through proper corrections for measured pulse height distributions with photopeak efficiency, Compton fraction, and K-escape fraction. The average energies and conversion coefficients obtained from the computation and experimental methods, when compared with ANSI N13.11 and the recently published National Institute of Standards and Technology X-ray beams, appeared to be in good agreement--(+/-)3% between corresponding values--and thus, could be satisfactorily applied in the performance test of personal dosimeters.
- 1 December 1997
- Published by American Chemical Society (ACS) in Environmental Health Perspectives
- Vol. 105 (suppl 6) , 1417-1421
Establishment of ANSI N13.11 X-ray radiation fields for personal dosimetry performance test by computation and experiment.
This paper describes establishment by computational and experimental methods of the American National Standard Institute (ANSI) N13.11 X-ray radiation fields by the Korea Atomic Energy Research Institute (KAERI). These fields were used in the standard irradiations of various personal dosimeters for the personal dosimetry performance test program performed by the Ministry of Science and Technology of Korea in the autumn of 1995. Theoretical X-ray spectra produced from two KAERI X-ray generators were estimated using a modified Kramers' theory with target attenuation and backscatter correction and their spectral distributions experimentally measured by a high-purity germanium semiconductor detector through proper corrections for measured pulse height distributions with photopeak efficiency, Compton fraction, and K-escape fraction. The average energies and conversion coefficients obtained from the computation and experimental methods, when compared with ANSI N13.11 and the recently published National Institute of Standards and Technology X-ray beams, appeared to be in good agreement--(+/-)3% between corresponding values--and thus, could be satisfactorily applied in the performance test of personal dosimeters.