Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Theresa Weith has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Florian Heberle

    Chair of Engineering Thermodynamics and Transport Processes (LTTT), Center of Energy Technology (ZET), University of Bayreuth, 95440 Bayreuth, Germany

    5 shared publications
  • Dieter Brüggemann

    Chair of Engineering Thermodynamics and Transport Processes (LTTT), University of Bayreuth, Universitätsstraße 30, 95440Bayreuth, Germany

    4 shared publications
  • Dieter Brüggemann

    Chair of Engineering Thermodynamics and Transport Processes (LTTT), Center of Energy Technology (ZET), University of Bayreuth, 95440 Bayreuth, Germany

    2 shared publications
  • Florian Heberle

    Chair of Engineering Thermodynamics and Transport Processes (LTTT), University of Bayreuth, Universitätsstraße 30, 95440Bayreuth, Germany

    2 shared publications
  • Markus Preißinger

    Lehrstuhl für Technische Thermodynamik und Transportprozesse, Zentrum für Energietechnik, Universität Bayreuth, Universitätsstraße 30, 95447 Bayreuth, Germany

    2 shared publications
  • Andreas König-Haagen

    1 shared publication

Latest Publications

  • Density and Viscosity of Linear Siloxanes and Their Mixtures

    by Zlatan Arnautovic, Sebastian Kutzner, Theresa Weith, Florian Heberle, Dieter Brüggemann


  • Open Access

    Experimental Characterization of an Adaptive Supersonic Micro Turbine for Waste Heat Recovery Applications

    by Tobias Popp, Andreas P. Weiß, Florian Heberle, Julia Winkler, Rüdiger Scharf, Theresa Weith, Dieter Brüggemann

    Micro turbines (el) are commercially used as expansion machines in waste heat recovery (WHR) systems such as organic Rankine cycles (ORCs). These highly loaded turbines are generally designed for a specific parameter set, and their isentropic expansion efficiency significantly deteriorates when the mass flow rate of the WHR system deviates from the design point. However, in numerous industry processes that are potentially interesting for the implementation of a WHR process, the temperature, mass flow rate or both can fluctuate significantly, resulting in fluctuations in the WHR system as well. In such circumstances, the inlet pressure of the ORC turbine, and therefore the reversible cycle efficiency must be significantly reduced during these fluctuations. In this context, the authors developed an adaptive supersonic micro turbine for WHR applications. The variable geometry of the turbine nozzles enables an adjustment of the swallowing capacity in respect of the available mass flow rate in order to keep the upper cycle pressure constant. In this paper, an experimental test series of a WHR ORC test rig equipped with the developed adaptive supersonic micro turbine is analysed. The adaptive turbine is characterized concerning its off-design performance and the results are compared to a reference turbine with fixed geometry. To create a fair data basis for this comparison, a digital twin of the plant based on experimental data was built. In addition to the characterization of the turbine itself, the influence of the improved pressure ratio on the energy conversion chain of the entire ORC is analysed.


  • Techno-economic feasibility analysis of zeotropic mixtures and pure fluids for organic Rankine cycle systems

    by Jesper Graa Andreasen, Enrico Baldasso, Martin Ryhl Kærn, Theresa Weith, Florian Heberle, Dieter Brüggemann, Fredrik Haglind


  • Open Access

    Experimental Long-Term Investigation of Model Predictive Heat Pump Control in Residential Buildings with Photovoltaic Power Generation

    by Sebastian Kuboth, Theresa Weith, Florian Heberle, Matthias Welzl, Dieter Brüggemann

    This article presents a 125-day experiment to investigate model predictive heat pump control. The experiment was performed in two parallel operated systems with identical components during the heating season. One of the systems was operated by a standard controller and thus represented a reference to evaluate the model predictive control. Both test rigs were heated by an air-source heat pump which is influenced by real weather conditions. A single-family house model depending on weather measurement data ensured a realistic heat consumption in the test rigs. The adapted model predictive control algorithm aimed to minimize the operational costs of the heat pump. The evaluation of the measurement results showed that the electrical energy demand of the heat pump can be reduced and the coefficient of performance can be increased by applying the model predictive controller. Furthermore, the self-consumption of photovoltaic electricity, which is calculated by means of a photovoltaic model and global radiation measurement data, was more than doubled. Consequently, the energy costs of heat pump operation were reduced by 9.0% in comparison to the reference and assuming German energy prices. The results were further compared to the scientific literature and short-term measurements were performed with the same experimental setup. The dependence of the measurement results on the weather conditions and the weather forecasting quality are shown. It was found that the duration of experiments should be as long as possible for a comprehensive evaluation of the model predictive control potential.


  • Experimental short-term investigation of model predictive heat pump control in residential buildings

    by Sebastian Kuboth, Florian Heberle, Theresa Weith, Matthias Welzl, Andreas König-Haagen, Dieter Brüggemann


  • Open Access

    Performance of Siloxane Mixtures in a High-Temperature Organic Rankine Cycle Considering the Heat Transfer Characteristics during Evaporation

    by Theresa Weith, Florian Heberle, Markus Preißinger, Dieter Brüggemann

    The application of the Organic Rankine Cycle to high temperature heat sources is investigated on the case study of waste heat recovery from a selected biogas plant. Two different modes of operation are distinguished: pure electric power and combined heat and power generation. The siloxanes hexamethyldisiloxane (MM) and octamethyltrisiloxane (MDM) are chosen as working fluids. Moreover, the effect of using mixtures of these components is analysed. Regarding pure electricity generation, process simulations using the simulation tool Aspen Plus show an increase in second law efficiency of 1.3% in case of 97/03 wt % MM/MDM-mixture, whereas for the combined heat and power mode a 60/40 wt % MM/MDM-mixture yields the highest efficiency with an increase of nearly 3% compared to most efficient pure fluid. Next to thermodynamic analysis, measurements of heat transfer coefficients of these siloxanes as well as their mixtures are conducted and Kandlikar’s correlation is chosen to describe the results. Based on that, heat exchanger areas for preheater and evaporator are calculated in order to check whether the poorer heat transfer characteristics of mixtures devalue their efficiency benefit due to increased heat transfer areas. Results show higher heat transfer areas of 0.9% and 14%, respectively, compared to MM.


  • Multi-Effect Plants and Ionic Liquids for Improved Absorption Chillers

    by Theresa Weith, Markus Preißinger, Simon Pöllinger, Dieter Brüggemann

    State-of-the-art absorption chillers using conventional working pairs still suffer from problems like crystallization, corrosiveness, and a relatively low efficiency. To improve this technology, different working pairs as well as plant designs are investigated using the simulation tool AspenPlus. The simulation is validated by comparing the results of single-effect absorption chillers using the current commercially applied working pairs water/lithium bromide and ammonia/water with literature data. To increase the efficiency, double-effect absorption chillers are implemented and analyzed. The performance of two kinds of double-effect cycles, series and parallel, is compared using the working pair water/lithium bromide. In addition, ionic liquids (ILs) are investigated as a sorbent in order to improve the technology. So far, ILs have not been implemented in AspenPlus yet. Therefore, a guideline for the implementation of ILs in AspenPlus is outlined and the accordant phase equilibria results are validated with literature data. Simulations of single-effect cycles using the ILs 1,3-dimethylimidazolium dimethylphosphate ([MMIM][DMP]) and 1-ethyl-3-methylimidazolium dimethylphosphate ([EMIM][DMP]) in combination with water as a refrigerant are performed and the results are compared to conventional working pairs. It is shown that by using ILs, similar or even higher coefficients of performance (COPs) can be achieved in comparison to conventional working pairs. Moreover, the findings reveal that the main benefit of using ILs as a sorbent consists in providing a broader operating range with respect to heat source temperature.


  • EXPERIMENTAL INVESTIGATION OF FLOW BOILING CHARACTERISTICS OF SILOXANES AND SILOXANE MIXTURES IN A HORIZONTAL TUBE

    by Theresa Weith, Florian Heberle, Dieter Bruggemann

    The present work shows results of an experimental investigation of heat transfer coefficients during flow boiling of siloxanes and siloxane mixtures. The main part of the test rig consists in a horizontal, plain tube out of stainless steel (inner diameter: 10 mm, wall thickness: 1 mm, length: 5.04 m), which is electrically heated by the Joule effect. The fluids hexamethyldisiloxane (MM) and octamethyltrisiloxane (MDM) are investigated. Mixtures in steps of 20 weight-percent of these two components are considered. The effect of pressure (pr = 0.4, Ts = 198 °C/220 °C), heat flux density (q = 9.5 −15.5 kW/m2) and mass flux density (G = 100 − 300 kg/m2s) on heat transfer is analysed. Regarding MM, the heat transfer coefficient decreases as the vapour quality increases. The variation of mass flux density shows higher heat transfer coefficients when raising the mass flux. An increase in heat flux density as well as pressure leads to no explicit influence on heat transfer coefficients in the investigated range. The measured heat transfer coefficients of MDM are on average higher than those of MM due to differences in transport properties and flow regimes. For siloxane mixtures, the average heat transfer coefficients are below the ones of pure components. The correlation by Kandlikar for pure fluids as well as for fluid mixtures predicts the general trend of heat transfer coefficient with respect to vapour quality and mass flux density. However, the values are overestimated by the correlation.